Quantitative Evaluation of Cerebral Blood Flow and Oxygen Metabolism in Normal Anesthetized Rats: 15O-Labeled Gas Inhalation PET with MRI Fusion

被引:20
|
作者
Watabe, Tadashi [1 ,2 ]
Shimosegawa, Eku [1 ]
Watabe, Hiroshi [3 ]
Kanai, Yasukazu [3 ]
Hanaoka, Kohei [1 ]
Ueguchi, Takashi [4 ]
Isohashi, Kayako [1 ]
Kato, Hiroki [1 ]
Tatsumi, Mitsuaki [4 ]
Hatazawa, Jun [1 ,2 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Nucl Med & Tracer Kinet, Suita, Osaka, Japan
[2] Osaka Univ, Immunol Frontier Res Ctr, Suita, Osaka, Japan
[3] Osaka Univ, Grad Sch Med, Dept Mol Imaging Med, Suita, Osaka, Japan
[4] Osaka Univ Hosp, Dept Radiol, Suita, Osaka, Japan
关键词
O-15-gas PET; CBF; OEF; CMRO2; POSITRON-EMISSION-TOMOGRAPHY; BRAIN; O-15; EXTRACTION; CONSUMPTION; VALIDATION; ISCHEMIA; STROKE; VOLUME; MODEL;
D O I
10.2967/jnumed.112.109751
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PET with O-15 gas has been used for the quantitative measurement of cerebral blood flow (CBF), cerebral metabolic rate of oxygen (CMRO2), oxygen extraction fraction (OEF), and cerebral blood volume (CBV) in humans. However, several technical difficulties limit its use in experiments on small animals. Herein, we describe the application of the O-15 gas steady-state inhalation method for normal anesthetized rats. Methods: Eight normal male Sprague-Dawley rats (mean body weight +/- SD, 268 +/- 14 g) under anesthesia were investigated by O-15-labeled gas PET. After tracheotomy, an airway tube was placed in the trachea, and the animals were connected to a ventilator (tidal volume, 3 cm(3); frequency, 60/min). The CBF and OEF were measured according to the original steady-state inhalation technique under artificial ventilation with O-15-CO2 and O-15-O-2 gases delivered through the radioactive gas stabilizer. CBV was measured by O-15-CO gas inhalation and corrected for the intravascular hemoglobinbound O-15-O-2. Arterial blood sampling was performed during each study to measure the radioactivity of the whole blood and plasma. MR image was performed with the same acrylic animal holder immediately after the PET. Regions of interest were placed on the whole brain of the PET images with reference to the semiautomatically coregistered PET/MR fused images. Results: The data acquisition time for the whole PET experiment in each rat was 73.3 +/- 5.8 (range, 68-85) min. In both the O-15-CO2 and the O-15-O-2 studies, the radioactivity count of the brain reached a steady state by approximately 10 min after the start of continuous inhalation of the gas. The quantitative PET data of the whole brain were as follows: CBF, 32.3 +/- 4.5 mL/100 mL/min; CMRO2, 3.23 +/- 0.42 mL/100 mL/min; OEF, 64.6% +/- 9.1%; and CBV, 5.05 +/- 0.45 mL/100 mL. Conclusion: Although further technical improvements may be needed, this study demonstrated the feasibility of quantitative PET measurement of CBF, OEF, and CMRO2 using the original steady-state inhalation method of O-15-CO2 and O-15-O-2 gases and measurement of CBV using the O-15-CO gas inhalation method in the brain of normal anesthetized rats.
引用
收藏
页码:283 / 290
页数:8
相关论文
共 33 条
  • [11] PET 0-15 cerebral blood flow and metabolism after acute stroke in spontaneously hypertensive rats
    Temma, Takashi
    Kuge, Yuji
    Sano, Kohei
    Kamihashi, Junko
    Obokata, Naoyuki
    Kawashima, Hidekazu
    Magata, Yasuhiro
    Saji, Hideo
    BRAIN RESEARCH, 2008, 1212 : 18 - 24
  • [12] Rapid quantitative measurement of CMRO2 and GBF by dual administration of 15O-labeled oxygen and water during a single PET scan -: a validation study and error analysis in anesthetized monkeys
    Kudomi, N
    Hayashi, T
    Teramoto, N
    Watabe, H
    Kawachi, N
    Ohta, Y
    Kim, KM
    Iida, H
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2005, 25 (09) : 1209 - 1224
  • [13] Quantification of brain oxygen extraction and metabolism with [15O]-gas PET: A technical review in the era of PET/MRI
    Fan, Audrey P.
    An, Hongyu
    Moradi, Farshad
    Rosenberg, Jarrett
    Ishii, Yosuke
    Nariai, Tadashi
    Okazawa, Hidehiko
    Zaharchuk, Greg
    NEUROIMAGE, 2020, 220
  • [14] Sequential PET estimation of cerebral oxygen metabolism with spontaneous respiration of 15O-gas in mice with bilateral common carotid artery stenosis
    Temma, Takashi
    Yamazaki, Makoto
    Miyanohara, Jun
    Shirakawa, Hisashi
    Kondo, Naoya
    Koshino, Kazuhiro
    Kaneko, Shuji
    Iida, Hidehiro
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2017, 37 (10) : 3334 - 3343
  • [15] Quantification of cerebral blood flow and oxygen metabolism with 3-dimensional PET and 15O:: Validation by comparison with 2-dimensional PET
    Ibaraki, Masanobu
    Miura, Shuichi
    Shimosegawa, Eku
    Sugawara, Shigeki
    Mizuta, Tetsuro
    Ishikawa, Akihiro
    Amano, Masaharu
    JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (01) : 50 - 59
  • [16] In vivo estimation of cerebral blood flow, oxygen consumption and glucose metabolism in the pig by [15O]water injection, [15O]oxygen inhalation and dual injections of [18F]fluorodeoxyglucose
    Poulsen, PH
    Smith, DF
    Ostergaard, L
    Danielsen, EH
    Gee, A
    Hansen, SB
    Astrup, J
    Gjedde, A
    JOURNAL OF NEUROSCIENCE METHODS, 1997, 77 (02) : 199 - 209
  • [17] Cerebrovascular Occlusive Disease: Quantitative Cerebral Blood Flow Using Dynamic Susceptibility Contrast MR Imaging Correlates with Quantitative H2 [15O] PET
    Vakil, Parmede
    Lee, John J.
    Mouannes-Srour, Jessy J.
    Derdeyn, Colin P.
    Carroll, Timothy J.
    RADIOLOGY, 2013, 266 (03) : 879 - 886
  • [18] Global cerebral blood flow after CO2 inhalation in normal subjects and patients with panic disorder determined with [15O]water and PET
    Ponto, LLB
    Kathol, RG
    Kettelkamp, R
    Watkins, GL
    Richmond, JCW
    Clark, J
    Hichwa, RD
    JOURNAL OF ANXIETY DISORDERS, 2002, 16 (03) : 247 - 258
  • [19] Quantitative Cerebral Blood Flow with Bolus Tracking Perfusion MRI: Measurements in Porcine Model and Comparison with H215O PET
    Kellner, Elias
    Mix, Michael
    Reisert, Marco
    Foerster, Katharina
    Thao Nguyen-Thanh
    Splitthoff, Daniel Nico
    Gall, Peter
    Kiselev, Valerij G.
    Mader, Irina
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (06) : 1723 - 1734
  • [20] Evaluation of a commercial PET tomograph-based system for the quantitative assessment of rCBF, rOEF and rCMRO2 by using sequential administration of 15O-labeled compounds
    Miho Shidahara
    Hiroshi Watabe
    Kyeong Min Kim
    Hisashi Oka
    Masayoshi Sago
    Takuya Hayashi
    Yoshinori Miyake
    Yoshio Ishida
    Kohei Hayashida
    Takashi Nakamura
    Hidehiro Iida
    Annals of Nuclear Medicine, 2002, 16 : 317 - 327