Quantitative Evaluation of Cerebral Blood Flow and Oxygen Metabolism in Normal Anesthetized Rats: 15O-Labeled Gas Inhalation PET with MRI Fusion

被引:20
|
作者
Watabe, Tadashi [1 ,2 ]
Shimosegawa, Eku [1 ]
Watabe, Hiroshi [3 ]
Kanai, Yasukazu [3 ]
Hanaoka, Kohei [1 ]
Ueguchi, Takashi [4 ]
Isohashi, Kayako [1 ]
Kato, Hiroki [1 ]
Tatsumi, Mitsuaki [4 ]
Hatazawa, Jun [1 ,2 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Nucl Med & Tracer Kinet, Suita, Osaka, Japan
[2] Osaka Univ, Immunol Frontier Res Ctr, Suita, Osaka, Japan
[3] Osaka Univ, Grad Sch Med, Dept Mol Imaging Med, Suita, Osaka, Japan
[4] Osaka Univ Hosp, Dept Radiol, Suita, Osaka, Japan
关键词
O-15-gas PET; CBF; OEF; CMRO2; POSITRON-EMISSION-TOMOGRAPHY; BRAIN; O-15; EXTRACTION; CONSUMPTION; VALIDATION; ISCHEMIA; STROKE; VOLUME; MODEL;
D O I
10.2967/jnumed.112.109751
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PET with O-15 gas has been used for the quantitative measurement of cerebral blood flow (CBF), cerebral metabolic rate of oxygen (CMRO2), oxygen extraction fraction (OEF), and cerebral blood volume (CBV) in humans. However, several technical difficulties limit its use in experiments on small animals. Herein, we describe the application of the O-15 gas steady-state inhalation method for normal anesthetized rats. Methods: Eight normal male Sprague-Dawley rats (mean body weight +/- SD, 268 +/- 14 g) under anesthesia were investigated by O-15-labeled gas PET. After tracheotomy, an airway tube was placed in the trachea, and the animals were connected to a ventilator (tidal volume, 3 cm(3); frequency, 60/min). The CBF and OEF were measured according to the original steady-state inhalation technique under artificial ventilation with O-15-CO2 and O-15-O-2 gases delivered through the radioactive gas stabilizer. CBV was measured by O-15-CO gas inhalation and corrected for the intravascular hemoglobinbound O-15-O-2. Arterial blood sampling was performed during each study to measure the radioactivity of the whole blood and plasma. MR image was performed with the same acrylic animal holder immediately after the PET. Regions of interest were placed on the whole brain of the PET images with reference to the semiautomatically coregistered PET/MR fused images. Results: The data acquisition time for the whole PET experiment in each rat was 73.3 +/- 5.8 (range, 68-85) min. In both the O-15-CO2 and the O-15-O-2 studies, the radioactivity count of the brain reached a steady state by approximately 10 min after the start of continuous inhalation of the gas. The quantitative PET data of the whole brain were as follows: CBF, 32.3 +/- 4.5 mL/100 mL/min; CMRO2, 3.23 +/- 0.42 mL/100 mL/min; OEF, 64.6% +/- 9.1%; and CBV, 5.05 +/- 0.45 mL/100 mL. Conclusion: Although further technical improvements may be needed, this study demonstrated the feasibility of quantitative PET measurement of CBF, OEF, and CMRO2 using the original steady-state inhalation method of O-15-CO2 and O-15-O-2 gases and measurement of CBV using the O-15-CO gas inhalation method in the brain of normal anesthetized rats.
引用
收藏
页码:283 / 290
页数:8
相关论文
共 33 条
  • [1] System evaluation of automated production and inhalation of 15O-labeled gaseous radiopharmaceuticals for the rapid 15O-oxygen PET examinations
    Iguchi, Satoshi
    Moriguchi, Tetsuaki
    Yamazaki, Makoto
    Hori, Yuki
    Koshino, Kazuhiro
    Toyoda, Kazunori
    Teuho, Jarmo
    Shimochi, Saeka
    Terakawa, Yusuke
    Fukuda, Tetsuya
    Takahashi, Jun C.
    Nakagawara, Jyoji
    Kanaya, Shigehiko
    Iida, Hidehiro
    EJNMMI PHYSICS, 2018, 5
  • [2] Validity of using a 3-dimensional PET scanner during inhalation of 15O-labeled oxygen for quantitative assessment of regional metabolic rate of oxygen in man
    Hori, Yuki
    Hirano, Yoshiyuki
    Koshino, Kazuhiro
    Moriguchi, Tetsuaki
    Iguchi, Satoshi
    Yamamoto, Akihide
    Enmi, Junichiro
    Kawashima, Hidekazu
    Zeniya, Tsutomu
    Morita, Naomi
    Nakagawara, Jyoji
    Casey, Michael E.
    Iida, Hidehiro
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (18) : 5593 - 5609
  • [3] Integrated PET/MRI scanner with oxygen-15 labeled gases for quantification of cerebral blood flow, cerebral blood volume, cerebral oxygen extraction fraction and cerebral metabolic rate of oxygen
    Hiroshi Ito
    Hitoshi Kubo
    Kazuhiro Takahashi
    Ken-Ichi Nishijima
    Naoyuki Ukon
    Ayaka Nemoto
    Shigeyasu Sugawara
    Ryo Yamakuni
    Masanobu Ibaraki
    Shiro Ishii
    Annals of Nuclear Medicine, 2021, 35 : 421 - 428
  • [4] Integrated PET/MRI scanner with oxygen-15 labeled gases for quantification of cerebral blood flow, cerebral blood volume, cerebral oxygen extraction fraction and cerebral metabolic rate of oxygen
    Ito, Hiroshi
    Kubo, Hitoshi
    Takahashi, Kazuhiro
    Nishijima, Ken-Ichi
    Ukon, Naoyuki
    Nemoto, Ayaka
    Sugawara, Shigeyasu
    Yamakuni, Ryo
    Ibaraki, Masanobu
    Ishii, Shiro
    ANNALS OF NUCLEAR MEDICINE, 2021, 35 (04) : 421 - 428
  • [5] Myocardial Blood Flow and Metabolic Rate of Oxygen Measurement in the Right and Left Ventricles at Rest and During Exercise Using 15O-Labeled Compounds and PET
    Kudomi, Nobuyuki
    Kalliokoski, Kari K.
    Oikonen, Vesa J.
    Han, Chunlei
    Kemppainen, Jukka
    Sipila, Hannu T.
    Knuuti, Juhani
    Heinonen, Ilkka H. A.
    FRONTIERS IN PHYSIOLOGY, 2019, 10
  • [6] Evaluation of the default-mode network by quantitative 15O-PET: comparative study between cerebral blood flow and oxygen consumption
    Aoe, Jo
    Watabe, Tadashi
    Shimosegawa, Eku
    Kato, Hiroki
    Kanai, Yasukazu
    Naka, Sadahiro
    Matsunaga, Keiko
    Isohashi, Kayako
    Tatsumi, Mitsuaki
    Hatazawa, Jun
    ANNALS OF NUCLEAR MEDICINE, 2018, 32 (07) : 485 - 491
  • [7] Quantitative evaluation of oxygen metabolism in the intratumoral hypoxia: 18F-fluoromisonidazole and 15O-labelled gases inhalation PET
    Watabe, Tadashi
    Kanai, Yasukazu
    Ikeda, Hayato
    Horitsugi, Genki
    Matsunaga, Keiko
    Kato, Hiroki
    Isohashi, Kayako
    Abe, Kohji
    Shimosegawa, Eku
    Hatazawa, Jun
    EJNMMI RESEARCH, 2017, 7
  • [8] Noninvasive method for measurement of cerebral blood flow using O-15 water PET/MRI with ASL correlation
    Okazawa, Hidehiko
    Higashino, Yoshifumi
    Tsujikawa, Tetsuya
    Arishima, Hidetaka
    Mori, Tetsuya
    Kiyono, Yasushi
    Kimura, Hirohiko
    Kikuta, Ken-ichiro
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 105 : 102 - 109
  • [9] Assessment of cerebral blood flow and metabolism in vertebrobasilar insufficiency with (133)Xenon and O-15 inhalation methods
    Nighoghossian, N
    Trouillas, P
    NEUROLOGICAL RESEARCH, 1997, 19 (02) : 165 - 168
  • [10] Comparative analysis of peri-nidal cerebral blood flow and metabolism using a novel quantitative 15O-PET method in patients with arteriovenous malformations
    Maruyama, Daisuke
    Iida, Hidehiro
    Koshino, Kazuhiro
    Nakagawara, Jyoji
    Morita, Yoshiaki
    Hashimura, Naoki
    Mori, Hisae
    Satow, Tetsu
    Takahashi, Jun C.
    Fukuda, Tetsuya
    Iihara, Koji
    Kataoka, Hiroharu
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2025, 45 (02) : 259 - 274