共 75 条
Fourth-Arm Common-Mode Voltage Mitigation
被引:30
作者:
Dagan, Kfir J.
[1
]
Zuckerberger, Adrian
[2
]
Rabinovici, Raul
[1
]
机构:
[1] Ben Gurion Univ Negev, Dept Elect & Comp Engn, IL-84105 Beer Sheva, Israel
[2] A2Z Consulting Ltd, IL-20142 Misgav, Israel
关键词:
Common-mode voltage;
feed-forward control;
pulse-width modulation;
voltage source inverter;
ADJUSTABLE SPEED DRIVES;
REDUCTION PWM TECHNIQUE;
INDUCTION-MOTOR DRIVES;
INVERTER OUTPUT FILTER;
BEARING CURRENTS;
ELECTROMAGNETIC-INTERFERENCE;
CLAMPED INVERTER;
SYSTEM-DESIGN;
EMI FILTERS;
AC MOTORS;
D O I:
10.1109/TPEL.2015.2417804
中图分类号:
TM [电工技术];
TN [电子技术、通信技术];
学科分类号:
0808 ;
0809 ;
摘要:
The adverse effect of common-mode voltage (CMV) in pulse-width modulation inverters is widely acknowledged. Various approaches for mitigating CMV effect in PWM inverters have been proposed in the literature but they either show limited effect or impair the utilization of the drive. This paper proposes an active method for eliminating CMV in multilevel inverters which is independent on the inverter topology or its modulation scheme. In particular, the proposed method does not restrict the modulation index range of the drive. A detailed analysis of the active filter circuitry and a closed-form feed-forward control law are provided. Finally, selected simulation and experimental results are presented to validate the theoretical part.
引用
收藏
页码:1401 / 1407
页数:7
相关论文