In vivo relaxation times of gray matter and white matter in spinal cord

被引:25
作者
Narayana, P [1 ]
Fenyes, D [1 ]
Zacharopoulos, N [1 ]
机构
[1] Univ Texas, Sch Med, Dept Radiol, Houston, TX 77030 USA
关键词
spinal cord; relaxation times; spin densities;
D O I
10.1016/S0730-725X(98)00194-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In vivo relaxation times and relative spin densities of gray matter (GM) and white matter (WM) of rat spinal cord were measured. Inductively coupled implanted RF coil was used to improve the signal-to-noise ratio required for making these measurements, The estimated relaxation times tin milliseconds) are: T-1(GM) = 1021 +/- 93, T-2(GM) = 64 +/- 3.4, T-1(WM) = 1089 +/- 126, and T-2 (WM) = 79 +/- 6.9, The estimated relative spin densities are: rho (GM) (60 +/- 2.3)% and rho (WM) = (40 +/- 2.1)%, The T-1 values of GM and white matter are not statistically different. However, the differences in T-2 values and spin densities of GM and WM are statistically significant. These in vivo measurements indicate that the observed contrast between GM and WM in spinal cord MR images mainly arises from the differences in the spin density. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:623 / 626
页数:4
相关论文
共 9 条
  • [1] CARVLIN MJ, 1989, AM J NEURORADIOL, V10, P13
  • [2] QUANTITATIVE MRI OF SPINAL-CORD INJURY IN A RAT MODEL
    FALCONER, JC
    NARAYANA, PA
    BHATTACHARJEE, MB
    LIU, SJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (04) : 484 - 491
  • [3] MAXIMIZING CONTRAST TO NOISE WITH INDUCTIVELY COUPLED IMPLANTED COILS
    FARMER, THR
    COFER, GP
    JOHNSON, GA
    [J]. INVESTIGATIVE RADIOLOGY, 1990, 25 (05) : 552 - 558
  • [4] In vivo echo-planar imaging of rat spinal cord
    Fenyes, DA
    Narayana, PA
    [J]. MAGNETIC RESONANCE IMAGING, 1998, 16 (10) : 1249 - 1255
  • [5] A METHOD FOR IN-VIVO HIGH-RESOLUTION MRI OF RAT SPINAL-CORD INJURY
    FORD, JC
    HACKNEY, DB
    JOSEPH, PM
    PHELAN, M
    ALSOP, DC
    TABOR, SL
    HAND, CM
    MARKOWITZ, RS
    BLACK, P
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (02) : 218 - 223
  • [6] Melhem ER, 1997, AM J NEURORADIOL, V18, P447
  • [7] RAPID INVIVO PROTON SHIMMING
    SCHNEIDER, E
    GLOVER, G
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) : 335 - 347
  • [8] RAPID, FULLY-AUTOMATIC, ARBITRARY-VOLUME INVIVO SHIMMING
    WEBB, P
    MACOVSKI, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 20 (01) : 113 - 122
  • [9] A COMPARISON OF AN INDUCTIVELY-COUPLED IMPLANTED COIL WITH OPTIMIZED SURFACE COILS FOR IN-VIVO NMR IMAGING OF THE SPINAL-CORD
    WIRTH, ED
    MARECI, TH
    BECK, BL
    FITZSIMMONS, JR
    REIER, PJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (05) : 626 - 633