摘要
In this work, experimental tests carried out on San Julian's stone samples (a calcarenite with which are constructed almost all the historical buildings of the city of Alicante, Spain) were made to assess the effect of FRP retrofitting after high temperature damage. Samples were exposed to real fire in the facilities of the Provincial Consortium of Firemen of Alicante. Besides, two different cooling methods were used: dry cooled at room temperature and fast cooling by spraying with cold water. In addition, two different FRP wrapping systems were used: carbon and glass unidirectional fibre fabrics, both embedded in epoxy resin. Fire-damaged specimens suffered a remarkable loss of strength and stiffness, greater in water cooled samples. The FRP jacket changes the mechanical behaviour and stress-strain curves showed an approximately bilinear response, with compressive stresses at failure in the order of 50 MPa and ultimate strain between 3-4%.
引用
收藏
页码:317 / 327
页数:11
相关论文
共 13 条
[1]  
ACI (American Concrete Institute), 2017, 4402R17 ACI
[2]   Structural upgrading of masonry columns by using composite reinforcements [J].
Aiello, Maria Antonietta ;
Micelli, Francesco ;
Valente, Luca .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2007, 11 (06) :650-658
[3]  
[Anonymous], 2014, GB/T 3354-2014
[4]   Strengthening fire-damaged concrete by confinement with fibre-reinforced polymer wraps [J].
Bisby, L. A. ;
Chen, J. F. ;
Li, S. Q. ;
Stratford, T. J. ;
Cueva, N. ;
Crossling, K. .
ENGINEERING STRUCTURES, 2011, 33 (12) :3381-3391
[5]   Temperature influence on the physical and mechanical properties of a porous rock: San Julian's calcarenite [J].
Brotons, V. ;
Tomas, R. ;
Ivorra, S. ;
Alarcon, J. C. .
ENGINEERING GEOLOGY, 2013, 167 :117-127
[6]  
CNR, 2013, CNRDT200R12013
[7]   FRP Confinement of Tuff and Clay Brick Columns: Experimental Study and Assessment of Analytical Models [J].
Di Ludovico, Marco ;
D'Ambra, Claudio ;
Prota, Andrea ;
Manfredi, Gaetano .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2010, 14 (05) :583-596
[8]  
Estevan L., 2016, EUR AM C REH BURG SP, P1457
[9]   Changes in sandstones of historical monuments exposed to fire or high temperature [J].
Hajpál, M .
FIRE TECHNOLOGY, 2002, 38 (04) :373-382
[10]   Changes in the engineering properties of marble in fire-exposed columns [J].
Koca, MY ;
Ozden, G ;
Yavuz, AB ;
Kincal, C ;
Onargan, T ;
Kucuk, K .
INTERNATIONAL JOURNAL OF ROCK MECHANICS AND MINING SCIENCES, 2006, 43 (04) :520-530