A Poroelastic Fluid/Structure-Interaction Model of Cerebrospinal Fluid Dynamics in the Cord With Syringomyelia and Adjacent Subarachnoid-Space Stenosis

被引:13
作者
Bertram, C. D. [1 ]
Heil, M. [2 ]
机构
[1] Univ Sydney, Sch Math & Stat, Sydney, NSW 2006, Australia
[2] Univ Manchester, Sch Math, Manchester M13 9PL, Lancs, England
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2017年 / 139卷 / 01期
关键词
CHIARI-I MALFORMATION; SPINAL-CORD; PATHOPHYSIOLOGY; BRAIN; PATHOGENESIS; PRESSURE; ARTERIAL; FLOW;
D O I
10.1115/1.4034657
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An existing axisymmetric fluid/structure-interaction (FSI) model of the spinal cord, pia mater, subarachnoid space, and dura mater in the presence of syringomyelia and subarachnoid-space stenosis was modified to include porous solids. This allowed investigation of a hypothesis for syrinx fluid ingress from cerebrospinal fluid (CSF). Gross model deformation was unchanged by the addition of porosity, but pressure oscillated more in the syrinx and the subarachnoid space below the stenosis. The poroelastic model still exhibited elevated mean pressure in the subarachnoid space below the stenosis and in the syrinx. With realistic cord permeability, there was slight oscillatory shunt flow bypassing the stenosis via the porous tissue over the syrinx. Weak steady streaming flow occurred in a circuit involving craniocaudal flow through the stenosis and back via the syrinx. Mean syrinx volume was scarcely altered when the adjacent stenosis bisected the syrinx, but increased slightly when the syrinx was predominantly located caudal to the stenosis. The fluid content of the tissues over the syrinx oscillated, absorbing most of the radial flow seeping from the subarachnoid space so that it did not reach the syrinx. To a lesser extent, this cyclic swelling in a boundary layer of cord tissue just below the pia occurred all along the cord, representing a mechanism for exchange of interstitial fluid (ISF) and cerebrospinal fluid which could explain recent tracer findings without invoking perivascular conduits. The model demonstrates that syrinx volume increase is possible when there is subarachnoid-space stenosis and the cord and pia are permeable.
引用
收藏
页数:10
相关论文
共 17 条
  • [1] Evaluation by Fluid/Structure-Interaction Spinal-Cord Simulation of the Effects of Subarachnoid-Space Stenosis on an Adjacent Syrinx
    Bertram, C. D.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2010, 132 (06):
  • [2] A poroelastic fluid-structure interaction model of syringomyelia
    Heil, Matthias
    Bertram, Christopher D.
    JOURNAL OF FLUID MECHANICS, 2016, 809 : 360 - 389
  • [3] The influence of coughing on cerebrospinal fluid pressure in an in vitro syringomyelia model with spinal subarachnoid space stenosis
    Bryn A Martin
    Francis Loth
    Cerebrospinal Fluid Research, 6 (1):
  • [4] A Computational Model for the Dynamics of Cerebrospinal Fluid in the Spinal Subarachnoid Space
    Toro, Eleuterio F.
    Thornber, Ben
    Zhang, Qinghui
    Scoz, Alessia
    Contarino, Christian
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2019, 141 (01):
  • [5] Cerebrospinal fluid dynamics between the basal cisterns and the subarachnoid space of the optic nerve in patients with papilloedema
    Killer, Hanspeter Esriel
    Jaggi, Gregor Peter
    Miller, Neil R.
    Huber, Andreas R.
    Landolt, Hans
    Mironov, Angel
    Meyer, Peter
    Remonda, Luca
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (06) : 822 - 827
  • [6] Effects of fluid structure interaction in a three dimensional model of the spinal subarachnoid space
    Cheng, Shaokoon
    Fletcher, David
    Hemley, Sarah
    Stoodley, Marcus
    Bilston, Lynne
    JOURNAL OF BIOMECHANICS, 2014, 47 (11) : 2826 - 2830
  • [7] THE INFLUENCE OF COUGHING ON CEREBROSPINAL FLUID PRESSURE IN AN IN VITRO SYRINGOMYELIA MODEL WITH SPINAL CANAL STENOSIS
    Martin, Bryn A.
    Loth, Francis
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2009, PT A AND B, 2009, : 893 - 894
  • [8] PATHOLOGICAL BIOMECHANICS OF CEREBROSPINAL FLUID PRESSURE IN SYRINGOMYELIA: FLUID STRUCTURE INTERACTION OF AN IN VITRO COAXIAL ELASTIC TUBE SYSTEM
    Martin, Bryn A.
    Labuda, Richard
    Royston, Thomas J.
    Oshinski, John N.
    Iskandar, Bermans
    Loth, Francis
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2009, PT A AND B, 2009, : 941 - 942
  • [9] Comparison of numerical methods for cerebrospinal fluid representation and fluid-structure interaction during transverse impact of a finite element spinal cord model
    Rycman, Aleksander
    McLachlin, Stewart
    Cronin, Duane S.
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2022, 38 (03)
  • [10] Anthropomorphic Model of Intrathecal Cerebrospinal Fluid Dynamics Within the Spinal Subarachnoid Space: Spinal Cord Nerve Roots Increase Steady-Streaming
    Khani, Mohammadreza
    Sass, Lucas R.
    Xing, Tao
    Sharp, M. Keith
    Baledent, Olivier
    Martin, Bryn A.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2018, 140 (08):