Cross-sensitive rare-earth metal sensors based on bidentate neutral organophosphorus compounds and chlorinated cobalt dicarbollide

被引:30
作者
Legin, A. V.
Kirsanov, D. O.
Babain, V. A.
Borovoy, A. V.
Herbst, R. S.
机构
[1] St Petersburg Univ, Dept Chem, St Petersburg 199034, Russia
[2] VG Khlopin Radium Inst, St Petersburg 194021, Russia
[3] Idaho Natl Lab, Idaho Falls, ID 83415 USA
关键词
chemical sensors; rare-earth cations; organophosphorus compounds; chlorinated cobalt dicarbollide;
D O I
10.1016/j.aca.2006.03.115
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A variety of new chemical sensors (ion selective electrodes) for determination of rare-earth (RE) and trivalent metal cations such as yttrium(III), lanthanum(III), praseodymium(III), neodymium(HI) and europium(III) that are commonly present in aqueous radiological samples, e.g. in high-level liquid waste (HLW) and solutions from reprocessing spent nuclear fuel, have been developed and studied. The sensors are based on bidentate neutral organophosphorus compounds, such as methylene bridged diphosphine dioxides and carbamoylmethylphosphine oxides, which are efficient extractants, especially when used in conjunction with chlorinated cobalt dicarbollide, for recovery and concentration of the RE and actinide elements from acidic HLW derived from the nuclear fuel cycle. The sensors exhibit remarkable sensitivity to RE cations and indicate promise for HLW analysis. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:243 / 247
页数:5
相关论文
共 18 条
[1]   Chromium(III) ion-selective electrode based on 4-dimethylaminoazobenzene [J].
Abbaspour, A ;
Izadyar, A .
TALANTA, 2001, 53 (05) :1009-1013
[2]  
AKHOND M, 2004, SENSOR ACTUAT B-CHEM, V99, P210
[3]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[4]   COMPLEXES OF TRIVALENT LANTHANIDE AND ACTINIDE IONS .I. OUTER-SPHERE ION PAIRS [J].
CHOPPIN, GR ;
STRAZIK, WF .
INORGANIC CHEMISTRY, 1965, 4 (09) :1250-&
[5]  
GALL LN, 1992, DOKL AKAD NAUK+, V325, P514
[6]   Chemical sensor for lanthanum(III) determination using aza-crown as ionophore in poly(vinyl chloride) matrix [J].
Gupta, VK ;
Jain, S ;
Chandra, S .
ANALYTICA CHIMICA ACTA, 2003, 486 (02) :199-207
[7]   Polymeric sensors based on extraction systems for determination of rare-earth metals [J].
Kirsanov, DO ;
Legin, AV ;
Babain, VA ;
Vlasov, YG .
RUSSIAN JOURNAL OF APPLIED CHEMISTRY, 2005, 78 (04) :568-573
[8]   Plutonium(III)-ion selective electrode of liquid membrane type using multidentate phosphine oxide ionophore [J].
Kitatsuji, Y ;
Aoyagi, H ;
Yoshida, Z ;
Kihara, S .
ANALYTICA CHIMICA ACTA, 1999, 387 (02) :181-187
[9]   The features of the electronic tongue in comparison with the characteristics of the discrete ion-selective sensors [J].
Legin, AV ;
Rudnitskaya, AM ;
Vlasov, YG ;
Di Natale, C ;
D'Amico, A .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 58 (1-3) :464-468
[10]   EFFECT OF THE STRUCTURE OF DIALKYL (ARYL) [DIALKYLCARBAMOYLMETHYL] PHOSPHINE OXIDES ON THEIR EXTRACTION CAPACITY AND SELECTIVITY [J].
MYASOEDOV, BF ;
CHMUTOVA, MK ;
KOCHETKOVA, NE ;
KOIRO, OE ;
PRIBYLOVA, GA ;
NESTEROVA, NP ;
MEDVED, TY ;
KABACHNIK, MI .
SOLVENT EXTRACTION AND ION EXCHANGE, 1986, 4 (01) :61-81