Hepatic malignant tumour versus cavernous haemangioma: Differentiation on multiple breath-hold turbo spin-echo MRI sequences with different T2-weighting and T2-relaxation time measurements on a single slice multi-echo sequence
被引:17
作者:
Chan, YL
论文数: 0引用数: 0
h-index: 0
机构:Chinese Univ Hong Kong, Prince Wales Hosp, Dept Diagnost Radiol, Shatin, Hong Kong, Peoples R China
Chan, YL
Lee, SF
论文数: 0引用数: 0
h-index: 0
机构:Chinese Univ Hong Kong, Prince Wales Hosp, Dept Diagnost Radiol, Shatin, Hong Kong, Peoples R China
Lee, SF
Yu, SCH
论文数: 0引用数: 0
h-index: 0
机构:Chinese Univ Hong Kong, Prince Wales Hosp, Dept Diagnost Radiol, Shatin, Hong Kong, Peoples R China
Yu, SCH
Lai, P
论文数: 0引用数: 0
h-index: 0
机构:Chinese Univ Hong Kong, Prince Wales Hosp, Dept Diagnost Radiol, Shatin, Hong Kong, Peoples R China
Lai, P
Ching, ASC
论文数: 0引用数: 0
h-index: 0
机构:Chinese Univ Hong Kong, Prince Wales Hosp, Dept Diagnost Radiol, Shatin, Hong Kong, Peoples R China
Ching, ASC
机构:
[1] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Diagnost Radiol, Shatin, Hong Kong, Peoples R China
[2] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Organ Imaging, Shatin, Hong Kong, Peoples R China
[3] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Surg, Shatin, Hong Kong, Peoples R China
liver tumour;
cavernous haemangioma;
MRI;
signal intensity;
T2-relaxation time;
D O I:
10.1053/crad.2001.0763
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
AIM: We evaluated the signal intensity change on breath-hold turbo spin-echo (TSE) T2-weighted sequences using different echo times (TE) and T2-relaxation time measurements on a single slice eight-echo sequence in the differentiation of hepatic malignancy from cavernous haemangioma. MATERIALS AND METHODS: Breath-hold TSE T2-weighted axial images of the liver were performed at TEs of 80, 120 and 160 ms in 34 patients with focal liver lesions (13 with cavernous haemangiomas, 14 with hepatocellular carcinomas and seven with metastases). The lesion percentage signal intensity change on the lower TE image to the higher TE image was calculated. T2-relaxation time was measured on a single slice eight-echo sequence. RESULTS: The TE pair 80/160 ms on breath-hold TSE T2-weighted sequences gave a performance (100% sensitivity, 92% specificity, 95% positive predictive value and 100% negative predictive value) better than other TE pairs in differentiating haemangioma from malignancy. Addition of fat-suppression compromised the diagnostic performance for all TE-pairs. The use of T2 relaxation time threshold of < 112 ms as indicative of malignant lesion achieved a 100% sensitivity, 77% specificity. 88% Positive predictive value and 100% negative predictive value. CONCLUSION: Percentage signal intensity change on breath-hold TSE T2-weighted sequences at TE 80/160 ms appears to be a quick and potentially useful means of differentiating hepatic malignancy from haemangioma. (C) 2002 The Royal College of Radiologists.
机构:
Seoul Natl Univ Hosp, Coll Med, Dept Radiol, Chongno Gu, Seoul 110744, South KoreaSeoul Natl Univ Hosp, Coll Med, Dept Radiol, Chongno Gu, Seoul 110744, South Korea
Kim, TK
Lee, HJ
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ Hosp, Coll Med, Dept Radiol, Chongno Gu, Seoul 110744, South KoreaSeoul Natl Univ Hosp, Coll Med, Dept Radiol, Chongno Gu, Seoul 110744, South Korea
Lee, HJ
Jang, HJ
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ Hosp, Coll Med, Dept Radiol, Chongno Gu, Seoul 110744, South KoreaSeoul Natl Univ Hosp, Coll Med, Dept Radiol, Chongno Gu, Seoul 110744, South Korea
Jang, HJ
Kim, AY
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ Hosp, Coll Med, Dept Radiol, Chongno Gu, Seoul 110744, South KoreaSeoul Natl Univ Hosp, Coll Med, Dept Radiol, Chongno Gu, Seoul 110744, South Korea
Kim, AY
Han, JK
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ Hosp, Coll Med, Dept Radiol, Chongno Gu, Seoul 110744, South KoreaSeoul Natl Univ Hosp, Coll Med, Dept Radiol, Chongno Gu, Seoul 110744, South Korea
Han, JK
Choi, BI
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ Hosp, Coll Med, Dept Radiol, Chongno Gu, Seoul 110744, South KoreaSeoul Natl Univ Hosp, Coll Med, Dept Radiol, Chongno Gu, Seoul 110744, South Korea
Choi, BI
[J].
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING,
1998,
8
(06):
: 1213
-
1218
机构:
Seoul Natl Univ Hosp, Coll Med, Dept Radiol, Chongno Gu, Seoul 110744, South KoreaSeoul Natl Univ Hosp, Coll Med, Dept Radiol, Chongno Gu, Seoul 110744, South Korea
Kim, TK
Lee, HJ
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ Hosp, Coll Med, Dept Radiol, Chongno Gu, Seoul 110744, South KoreaSeoul Natl Univ Hosp, Coll Med, Dept Radiol, Chongno Gu, Seoul 110744, South Korea
Lee, HJ
Jang, HJ
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ Hosp, Coll Med, Dept Radiol, Chongno Gu, Seoul 110744, South KoreaSeoul Natl Univ Hosp, Coll Med, Dept Radiol, Chongno Gu, Seoul 110744, South Korea
Jang, HJ
Kim, AY
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ Hosp, Coll Med, Dept Radiol, Chongno Gu, Seoul 110744, South KoreaSeoul Natl Univ Hosp, Coll Med, Dept Radiol, Chongno Gu, Seoul 110744, South Korea
Kim, AY
Han, JK
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ Hosp, Coll Med, Dept Radiol, Chongno Gu, Seoul 110744, South KoreaSeoul Natl Univ Hosp, Coll Med, Dept Radiol, Chongno Gu, Seoul 110744, South Korea
Han, JK
Choi, BI
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ Hosp, Coll Med, Dept Radiol, Chongno Gu, Seoul 110744, South KoreaSeoul Natl Univ Hosp, Coll Med, Dept Radiol, Chongno Gu, Seoul 110744, South Korea
Choi, BI
[J].
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING,
1998,
8
(06):
: 1213
-
1218