Dispersive micro-solid phase extraction based on self-assembling, ionic liquid-coated magnetic particles for the determination of clofentezine and chlorfenapyr in environmental water samples

被引:31
作者
Peng, Bing [1 ]
Zhang, Jiaheng [1 ]
Lu, Runhua [1 ]
Zhang, Sanbing [1 ]
Zhou, Wenfeng [1 ]
Gao, Haixiang [1 ]
机构
[1] China Agr Univ, Dept Appl Chem, Beijing 100194, Peoples R China
基金
中国国家自然科学基金;
关键词
GAS-CHROMATOGRAPHY; MICROEXTRACTION; PERFORMANCE; PESTICIDES; NANOPARTICLES; CHLOROPHENOLS; INSECTICIDES; AGGREGATION; VALIDATION; TOXICITY;
D O I
10.1039/c3an00814b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two ionic liquid-coated-Fe3O4 magnetic particles (IL-Fe3O4 MPs) were developed for use in two types of dispersive micro-solid phase extraction (D-mu-SPE) for the high-performance liquid chromatographic analysis of clofentezine and chlorfenapyr in environmental water samples. Self-assembling IL-Fe3O4 MPs were used in D-mu-SPE as adsorbents. Two D-mu-SPE extraction methods, namely, direct dispersive micro-solid phase extraction (d-D-mu-SPE) and in situ solvent formation-based dispersive micro-solid phase extraction (ISF-D-mu-SPE), were proposed, using [C8MIM][PF6] to extract analytes through two pathways. Lower IL doses were required in the extraction process compared with those in other IL-based methods. Fe3O4 MPs can also be recycled and reused after extraction and are thus environmentally friendly. These newly developed methods were demonstrated to be feasible for use in the quantitation of clofentezine and chlorfenapyr at trace levels, with lower limit of detection values ranging from 0.4 to 0.5 ng mL(-1) for d-D-mu-SPE and 0.4 ng mL(-1) for ISF-D-mu-SPE. Finally, relative standard deviations of less than 6.0% were obtained.
引用
收藏
页码:6834 / 6843
页数:10
相关论文
共 47 条
[31]   Ultrasound-assisted ionic liquid dispersive liquid-liquid microextraction coupled with high performance liquid chromatography for sensitive determination of trace celastrol in urine [J].
Sun, Jian-Nan ;
Shi, Yan-Ping ;
Chen, Juan .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (30) :3429-3433
[32]   Preparation of alumina-coated magnetite nanoparticle for extraction of trimethoprim from environmental water samples based on mixed hemimicelles solid-phase extraction [J].
Sun, Lei ;
Zhang, Chuanzhou ;
Chen, Ligang ;
Liu, Jun ;
Jin, Haiyan ;
Xu, Haoyan ;
Ding, Lan .
ANALYTICA CHIMICA ACTA, 2009, 638 (02) :162-168
[33]  
Tomlin C., 1995, CROP PROTECTION PUBL
[34]   Application of SPE-HPLC-DAD and SPE-TLC-DAD to the determination of pesticides in real water samples [J].
Tuzimski, Tomasz .
JOURNAL OF SEPARATION SCIENCE, 2008, 31 (20) :3537-3542
[35]   Evaluation of a commercial immunoassay for the detection of chlorfenapyr in agricultural samples by comparison with gas chromatography and mass spectrometric detection [J].
Watanabe, E ;
Baba, K ;
Eun, H ;
Arao, T ;
Ishii, Y ;
Ueji, M ;
Endo, S .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1074 (1-2) :145-153
[36]   Development of liquid phase microextraction based on manual shaking and ultrasound-assisted emulsification method for analysis of organochlorine pesticides in aqueous samples [J].
Wei, Shuo-Yang ;
Leong, Mei-I ;
Li, Yee ;
Huang, Shang-Da .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (51) :9142-9148
[37]   Room-temperature ionic liquids. Solvents for synthesis and catalysis [J].
Welton, T .
CHEMICAL REVIEWS, 1999, 99 (08) :2071-2083
[38]   AIR AND WATER STABLE 1-ETHYL-3-METHYLIMIDAZOLIUM BASED IONIC LIQUIDS [J].
WILKES, JS ;
ZAWOROTKO, MJ .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1992, (13) :965-967
[39]   The use of gold nanoparticles in diagnostics and detection [J].
Wilson, Robert .
CHEMICAL SOCIETY REVIEWS, 2008, 37 (09) :2028-2045
[40]   Application of liquid-phase microextraction and gas chromatography to the determination of chlorfenapyr in water samples [J].
Wu, Yiping ;
Zhou, Zhiqiang .
MICROCHIMICA ACTA, 2008, 162 (1-2) :161-165