Impact of Remote Magnetic Catheter Navigation on Ablation Fluoroscopy and Procedure Time

被引:55
作者
Kim, Albert M. [1 ]
Turakhia, Mintu [1 ]
Lu, Jonathan [1 ]
Badhwar, Nitish [1 ]
Lee, Byron K. [1 ]
Lee, Randall J. [1 ]
Marcus, Gregory M. [1 ]
Tseng, Zian H. [1 ]
Scheinman, Melvin [1 ]
Olgin, Jeffrey E. [1 ]
机构
[1] Univ Calif San Francisco, San Francisco, CA 94143 USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2008年 / 31卷 / 11期
关键词
ablation; new technology; electrophysiology-clinical; atrial fibrillation;
D O I
10.1111/j.1540-8159.2008.01202.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Remote magnetic catheter navigation (RCN) is gaining acceptance in clinical cardiac electrophysiology, but details regarding how RCN affects procedure execution are not well characterized. Methods: From January 1, 2005, to November 30, 2007, 721 cases were retrospectively analyzed and compared. Of these, 127 used RCN and 594 used manual catheter navigation (MCN). Data including procedure time, fluoroscopy time, ablation catheter, procedural success, and complications were extracted from our procedure database and compared between RCN and MCN. Results: RCN use significantly decreased fluoroscopy time for atrial fibrillation (AF) ablation (-29 minutes, P < 0.001), atrioventricular nodal reentrant tachycardia ablation (-14 minutes, P < 0.001), and atrioventricular reentrant tachycardia ablation (-18 minutes, P = 0.045). While RCN significantly increased mean procedure time for AF (+36 minutes, P = 0.003) and atypical atrial flutter cases (+116 minutes, P = 0.016), RCN AF procedure time diminished with increasing number of cases performed. Two cases of tamponade occurred during AF ablation using MCN (2.2%, 2 of 91 cases). No tamponade occurred during all 75 AF ablations with RCN. Conclusion: RCN can reduce fluoroscopy time and may reduce complications during catheter ablation. While it may increase total procedure duration, procedure times decrease with increasing operator experience. (PACE 2008; 31: 1399-1404)
引用
收藏
页码:1399 / 1404
页数:6
相关论文
共 9 条
[1]   Remote-controlled catheter ablation of accessory pathways: results from the magnetic laboratory [J].
Chun, Julian Kyoung-Ryul ;
Ernst, Sabine ;
Matthews, Shibu ;
Schmidt, Boris ;
Bansch, Dietmar ;
Boczor, Sigrid ;
Ujeyl, Amaar ;
Antz, Matthias ;
Ouyang, Feifan ;
Kuck, Karl-Heinz .
EUROPEAN HEART JOURNAL, 2007, 28 (02) :190-195
[2]   Remote-controlled magnetic ablation of a right anterolateral accessory pathway - The superior caval vein approach [J].
Chun, Julian Kyoung-Ryul ;
Schmidt, Boris ;
Kuck, Karl-Heinz ;
Ernst, Sabine .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2006, 16 (01) :65-68
[3]   Remote magnetic navigation - Human experience in pulmonary vein ablation [J].
Di Blase, Luigi ;
Fahmy, Tamer S. ;
Patel, Dimpi ;
Bai, Rong ;
Civello, Kenneth ;
Wazni, Oussama M. ;
Kanj, Mohamed ;
Elayi, Claude S. ;
Ching, Chi Keong ;
Khan, Mohamed ;
Popova, Lucie ;
Schweikert, Robert A. ;
Cummings, Jennifer E. ;
Burkhardt, J. David ;
Martin, David O. ;
Bhargava, Mandeep ;
Dresing, Thomas ;
Saliba, Walid ;
Arruda, Mauricio ;
Natale, Andrea .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (09) :868-874
[4]   Remote catheter ablation of parahisian accessory pathways using a novel magnetic navigation system - A report of two cases [J].
Ernst, S ;
Hachiya, H ;
Chun, JKR ;
Ouyang, F .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2005, 16 (06) :659-662
[5]   Initial experience with remote catheter ablation using a novel magnetic navigation system -: Magnetic remote catheter ablation [J].
Ernst, S ;
Ouyang, FF ;
Linder, C ;
Hertting, K ;
Stahl, F ;
Chun, J ;
Hachiya, H ;
Bänsch, D ;
Antz, M ;
Kuck, KH .
CIRCULATION, 2004, 109 (12) :1472-1475
[6]   Modulation of the slow pathway in the presence of a persistent left superior caval vein using the novel magnetic navigation system Niobe [J].
Ernst, S ;
Ouyang, F ;
Linder, C ;
Hertting, K ;
Stahl, F ;
Chun, J ;
Hachiya, H ;
Krumsdorf, U ;
Antz, M ;
Kuck, KH .
EUROPACE, 2004, 6 (01) :10-14
[7]   Novel, magnetically guided catheter for endocardial mapping and radiofrequency catheter ablation [J].
Faddis, MN ;
Blume, W ;
Finney, J ;
Hall, A ;
Rauch, J ;
Sell, J ;
Bae, KT ;
Talcott, M ;
Lindsay, B .
CIRCULATION, 2002, 106 (23) :2980-2985
[8]   Magnetic guidance system for cardiac electrophysiology - A prospective trial of safety and efficacy in humans [J].
Faddis, MN ;
Chen, J ;
Osborn, J ;
Talcott, M ;
Cain, ME ;
Lindsay, BD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (11) :1952-1958
[9]   Robotic magnetic navigation for atrial fibrillation ablation [J].
Pappone, C ;
Vicedomini, G ;
Manguso, F ;
Gugliotta, F ;
Mazzone, P ;
Gulletta, S ;
Sora, N ;
Sala, S ;
Marzi, A ;
Augello, G ;
Livolsi, L ;
Santagostino, A ;
Santinelli, V .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (07) :1390-1400