Rotating Platform Revision Total Knee Arthroplasty

被引:7
作者
Goldstein, Wayne M. [1 ]
Gordon, Alexander C. [1 ]
Swope, Stephen [2 ]
Branson, Jill [1 ]
机构
[1] Illinois Bone & Joint Inst, Dept Orthopaed Surg, Morton Grove, IL 60053 USA
[2] DePuy Orthopaed Inc, Orthopaedics, Warsaw, IN USA
关键词
mobile bearing; knee arthroplasty; revision; outcome;
D O I
10.1055/s-0031-1286198
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Although revision total knee arthroplasty (TKA) procedures are successful in relieving pain and restoring function in failed knees, long-term results are inferior to primary procedures. Mobile bearing (MB) revision knees can potentially improve functional performance. Clinical results of 44 MB rotating platform (RP) revision TKAs demonstrated mean knee injury and osteoarthritis outcome score (KOOS) activity of daily living score of 77 2 years postoperatively. Clinical results were put into context through wear testing which demonstrated improved wear performance compared with fixed bearing (FB) revision knees. The RP construct is a good choice for revision TKA because it permits the surgeon to align the tray for fixation, not compromise rotation of the tibial insert, and reduce transmission of shear stresses to the bone, cement and implant interface, which is a known cause of failure.
引用
收藏
页码:45 / 50
页数:6
相关论文
共 9 条
[1]  
[Anonymous], 2002, 142431 ISO
[2]   Clinical wear measurement on low contact stress rotating platform knee bearings [J].
Atwood, Sara A. ;
Currier, John H. ;
Mayor, Michael B. ;
Collier, John P. ;
Van Citters, Douglas W. ;
Kennedy, Francis E. .
JOURNAL OF ARTHROPLASTY, 2008, 23 (03) :431-440
[3]   Long-term followup after mobile-bearing total knee replacement [J].
Buechel, FF .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (404) :40-50
[4]   Mobile-beading total knee arthroplasty - Do the polyethylene bearings rotate? [J].
Dennis, DA ;
Komistek, RD ;
Mahfouz, MR ;
Outten, JT ;
Sharma, A .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (440) :88-95
[5]   Mobile-bearing total knee arthroplasty - Design factors in minimizing wear [J].
Dennis, Douglas A. ;
Komistek, Richard A. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (452) :70-77
[6]   In vivo polyethylene bearing mobility is maintained in posterior stabilized total knee arthroplasty [J].
Komistek, RD ;
Dennis, DA ;
Mahfouz, MR ;
Walker, S ;
Outten, J .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (428) :207-213
[7]   Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002 [J].
Kurtz, S ;
Mowat, F ;
Ong, K ;
Chan, N ;
Lau, E ;
Halpern, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (07) :1487-1497
[8]   Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030 [J].
Kurtz, Steven ;
Ong, Kevin ;
Lau, Edmund ;
Mowat, Fionna ;
Halpern, Michael .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (04) :780-785
[9]   Why do revision knee arthroplasties fail? [J].
Suarez, Juan ;
Griffin, William ;
Springer, Bryan ;
Fehring, Thomas ;
Mason, J. Bohannon ;
Odum, Susan .
JOURNAL OF ARTHROPLASTY, 2008, 23 (06) :99-103