One-step construction of biosensor based on chitosan-ionic liquid-horseradish peroxidase biocomposite formed by electrodeposition

被引:73
作者
Xi, Fengna [1 ]
Liu, Lijun [1 ]
Wu, Qi [1 ]
Lin, Xianfu [1 ]
机构
[1] Zhejiang Univ, Dept Chem, Hangzhou 310027, Zhejiang, Peoples R China
关键词
biosensor; ionic liquids; biocomposite; electrodeposition; one-step; hydrogen peroxide;
D O I
10.1016/j.bios.2008.03.023
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A simple and controllable electrodeposition approach was established for one-step construction of hydrogen peroxide (H2O2) biosensors by in situ formation of chitosan-ionic liquid-horseradish peroxidase (CS-IL-HRP) biocomposite film on electrode surface. A highly porous surface with orderly three-dimensional network was revealed by scanning electron microscopy (SEM) investigation. The biocomposite provided improved conductivity and biocompatible microenvironment. The developed biosensor exhibited a fast amperometric response for the determination of H2O2 and 95% of the steady-state current was obtained within 2 s. The linear response of the developed biosensor for the determination of H2O2 ranged from 6.0 x 10(-7) to 1.6 x 10(-4) M with a detection limit of 1.5 x 10(-7) M. Performance of the biosensor was evaluated with respect to possible interferences and a good selectivity was revealed. The fabricated biosensor exhibited high reproducibility and long-time storage stability. The ease of the one-step non-manual technique and the promising feature of biocomposite could serve as a versatile platform for the fabrication of electrochemical biosensors. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:29 / 34
页数:6
相关论文
共 37 条
[1]   Ferrocene branched chitosan for the construction of a reagentless amperometric hydrogen peroxide biosensor [J].
Garcia, Ariel ;
Peniche-Covas, Carlos ;
Chico, Belkis ;
Simpson, Benjamin K. ;
Villalonga, Reynaldo .
MACROMOLECULAR BIOSCIENCE, 2007, 7 (04) :435-439
[2]   Immobilization of enzymes on the nano-Au film modified glassy carbon electrode for the determination of hydrogen peroxide and glucose [J].
Lei, CX ;
Wang, H ;
Shen, GL ;
Yu, RQ .
ELECTROANALYSIS, 2004, 16 (09) :736-740
[3]   Immobilization of horseradish peroxidase to a nano-Au monolayer modified chitosan-entrapped carbon paste electrode for the detection of hydrogen peroxide [J].
Lei, CX ;
Hu, SQ ;
Shen, GL ;
Yu, RQ .
TALANTA, 2003, 59 (05) :981-988
[4]   Electrochemical detection of nitric oxide on a SWCNT/RTIL composite gel microelectrode [J].
Li, CM ;
Zang, JF ;
Zhan, DP ;
Chen, W ;
Sun, CQ ;
Teo, AL ;
Chua, YT ;
Lee, VS ;
Moochhala, SM .
ELECTROANALYSIS, 2006, 18 (07) :713-718
[5]   Direct electrochemistry of glucose oxidase entrapped in nano gold particles-ionic liquid-N,N-dimethylformamide composite film on glassy carbon electrode and glucose sensing [J].
Li, Jiangwen ;
Yu, Jingjing ;
Zhao, Faqiong ;
Zeng, Baizhao .
ANALYTICA CHIMICA ACTA, 2007, 587 (01) :33-40
[6]   Amperometric sensor for hydrogen peroxide based on electric wire composed of horseradish peroxidase and toluidine blue-multiwalled carbon nanotubes nanocomposite [J].
Liu, Ying ;
Lei, Jianping ;
Ju, Huangxian .
TALANTA, 2008, 74 (04) :965-970
[7]   Composite system based on chitosan and room-temperature ionic liquid: Direct electrochemistry and electrocatalysis of hemoglobin [J].
Lu, XB ;
Hu, JQ ;
Yao, X ;
Wang, ZP ;
Li, JH .
BIOMACROMOLECULES, 2006, 7 (03) :975-980
[8]   Direct electron transfer of horseradish peroxidase and its biosensor based on chitosan and room temperature ionic liquid [J].
Lu, Xianbo ;
Zhang, Qian ;
Zhang, Ling ;
Li, Jinghong .
ELECTROCHEMISTRY COMMUNICATIONS, 2006, 8 (05) :874-878
[9]   Electrochemically deposited chitosan hydrogel for horseradish peroxidase immobilization through gold nanoparticles self-assembly [J].
Luo, XL ;
Xu, JJ ;
Zhang, Q ;
Yang, GJ ;
Chen, HY .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (01) :190-196
[10]   A glucose biosensor based on chitosan-glucose oxidase-gold nanoparticles biocomposite formed by one-step electrodeposition [J].
Luo, XL ;
Xu, JJ ;
Du, Y ;
Chen, HY .
ANALYTICAL BIOCHEMISTRY, 2004, 334 (02) :284-289