Performance evaluation of single-sided natural ventilation for generic building using large-eddy simulations: Effect of guide vanes and adjacent obstacles

被引:30
作者
Arinami, Yuki [1 ]
Akabayashi, Shin-ichi [2 ]
Tominaga, Yoshihide [3 ]
Sakaguchi, Jun [4 ]
机构
[1] Niigata Univ, Architecture Program, Fac Engn, Niigata, Japan
[2] Niigata Univ, Grad Sch Sci & Technol, Niigata, Japan
[3] Niigata Inst Technol, Wind & Fluid Engn Res Ctr, Kashiwazaki, Japan
[4] Univ Niigata Prefecture, Dept Int Studies & Reg Dev, Fac Int Studies & Reg Dev, Niigata, Japan
关键词
Single-sided natural ventilation; Performance evaluation; Guide vane; CFD; LES; WIND-DRIVEN VENTILATION; NUMERICAL-SIMULATION; AIR-FLOW; CROSS-VENTILATION; CFD SIMULATIONS; IMPACT; LES; DISPERSION; RANS;
D O I
10.1016/j.buildenv.2019.01.021
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A series of computational fluid dynamics simulations was performed using large-eddy simulation (LES) of single-sided natural ventilation for a generic building model, so as to investigate the impact of guide vanes (GVs) and adjacent obstacles on the air change rate and ventilation efficiency. A building model with two openings on one sidewall aligned parallel to the direction of the approaching wind was adopted for the study, and three different GV configurations were compared: no GVs, GVs installed at both ends of the two openings, and GVs installed at the center of the two openings. In addition, the shapes and distances of adjacent obstacles opposite the openings were considered as influencing parameters. It was confirmed that the flow property within the ventilated room was affected considerably by the GV and adjacent-obstacle location combination. A natural ventilation performance evaluation method that employs the fluctuating velocity field determined from the LES was proposed and applied to the predicted flow field. The contribution of the fluctuating velocity through the openings to the ventilation performance was evaluated quantitatively by considering both the fresh-air arrival rate to the occupied zone and the effective air change rate. The importance of considering the influence of the fluctuating velocity component on the air change rate and the arrival rate was discussed.
引用
收藏
页码:68 / 80
页数:13
相关论文
共 44 条
  • [1] Large-eddy Simulation of flow and dispersion around an isolated building: Analysis of influencing factors
    Ai, Z. T.
    Mak, C. M.
    [J]. COMPUTERS & FLUIDS, 2015, 118 : 89 - 100
  • [2] Analysis of fluctuating characteristics of wind-induced airflow through a single opening using LES modeling and the tracer gas technique
    Ai, Z. T.
    Mak, C. M.
    [J]. BUILDING AND ENVIRONMENT, 2014, 80 : 249 - 258
  • [3] Design analysis of single-sided natural ventilation
    Allocca, C
    Chen, QY
    Glicksman, LR
    [J]. ENERGY AND BUILDINGS, 2003, 35 (08) : 785 - 795
  • [4] [Anonymous], 2015, J ENV ENG T AIJ
  • [5] [Anonymous], 2016, J ENV AIJ, DOI DOI 10.3130/AIJE.81.589
  • [6] [Anonymous], 2015, J ENV ENG JAPAN
  • [7] [Anonymous], 2000, T JPN SOC MECH ENG, DOI DOI 10.1299/KIKAIB.66.649_2274
  • [8] Numerical simulation of single-sided ventilation using RANS and LES and comparison with full-scale experiments
    Caciolo, Marcello
    Stabat, Pascal
    Marchio, Dominique
    [J]. BUILDING AND ENVIRONMENT, 2012, 50 : 202 - 213
  • [9] Full scale experimental study of single-sided ventilation: Analysis of stack and wind effects
    Caciolo, Marcello
    Stabat, Pascal
    Marchio, Dominique
    [J]. ENERGY AND BUILDINGS, 2011, 43 (07) : 1765 - 1773
  • [10] Wind-driven natural ventilation for buildings with two openings on the same external wall
    Chu, Chia-Ren
    Chiu, Y. -H.
    Tsai, Yi-Ting
    Wu, Si-Lei
    [J]. ENERGY AND BUILDINGS, 2015, 108 : 365 - 372