A hybrid three-class brain-computer interface system utilizing SSSEPs and transient ERPs

被引:18
作者
Breitwieser, Christian [1 ]
Pokorny, Christoph [1 ]
Mueller-Putz, Gernot R. [1 ]
机构
[1] Graz Univ Technol, Lab Brain Comp Interfaces, Inst Neural Engn, Stremayrgasse 16, A-8010 Graz, Austria
关键词
brain-computer interface; BCI; steady-state somatosensory evoked potential; SSSEP; P300; tERP; hybrid; SOMATOSENSORY-EVOKED POTENTIALS; SPATIAL ATTENTION; TACTILE; VIBRATION; STIMULATION; ARTIFACTS; FREQUENCY; FINGERS; HAND;
D O I
10.1088/1741-2560/13/6/066015
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. This paper investigates the fusion of steady-state somatosensory evoked potentials (SSSEPs) and transient event-related potentials (tERPs), evoked through tactile simulation on the left and right-hand fingertips, in a three-class EEG based hybrid brain-computer interface. It was hypothesized, that fusing the input signals leads to higher classification rates than classifying tERP and SSSEP individually. Approach. Fourteen subjects participated in the studies, consisting of a screening paradigm to determine person dependent resonance-like frequencies and a subsequent online paradigm. The whole setup of the BCI system was based on open interfaces, following suggestions for a common implementation platform. During the online experiment, subjects were instructed to focus their attention on the stimulated fingertips as indicated by a visual cue. The recorded data were classified during runtime using a multi-class shrinkage LDA classifier and the outputs were fused together applying a posterior probability based fusion. Data were further analyzed offline, involving a combined classification of SSSEP and tERP features as a second fusion principle. The final results were tested for statistical significance applying a repeated measures ANOVA. Main results. A significant classification increase was achieved when fusing the results with a combined classification compared to performing an individual classification. Furthermore, the SSSEP classifier was significantly better in detecting a non-control state, whereas the tERP classifier was significantly better in detecting control states. Subjects who had a higher relative band power increase during the screening session also achieved significantly higher classification results than subjects with lower relative band power increase. Significance. It could be shown that utilizing SSSEP and tERP for hBCIs increases the classification accuracy and also that tERP and SSSEP are not classifying control- and non-control states with the same level of accuracy.
引用
收藏
页数:13
相关论文
共 41 条
[1]   Shift of attention to the body location of distracters is mediated by perceptual load in sustained somatosensory attention [J].
Adler, Julia ;
Giabbiconi, Claire-Marie ;
Mueller, Matthias M. .
BIOLOGICAL PSYCHOLOGY, 2009, 81 (02) :77-85
[2]   Toward a hybrid brain-computer interface based on imagined movement and visual attention [J].
Allison, B. Z. ;
Brunner, C. ;
Kaiser, V. ;
Mueller-Putz, G. R. ;
Neuper, C. ;
Pfurtscheller, G. .
JOURNAL OF NEURAL ENGINEERING, 2010, 7 (02)
[3]  
Billinger Martin., 2013, Towards Practical Brain-Computer Interfaces, P333, DOI [DOI 10.1007/978-3-642-29746-5_17, 10.1007/978-3-642-29746-517]
[4]   A high-speed BCI based on code modulation VEP [J].
Bin, Guangyu ;
Gao, Xiaorong ;
Wang, Yijun ;
Li, Yun ;
Hong, Bo ;
Gao, Shangkai .
JOURNAL OF NEURAL ENGINEERING, 2011, 8 (02)
[5]   VEP-Based Brain-Computer Interfaces: Time, Frequency, and Code Modulations [J].
Bin, Guangyu ;
Gao, Xiaorong ;
Wang, Yijun ;
Hong, Bo ;
Gao, Shangkai .
IEEE COMPUTATIONAL INTELLIGENCE MAGAZINE, 2009, 4 (04) :22-26
[6]  
Bishop C., 2006, Pattern recognition and machine learning, P423
[7]  
Breitwieser C, 2016, CORR
[8]   Stability and distribution of steady-state somatosensory evoked potentials elicited by vibro-tactile stimulation [J].
Breitwieser, Christian ;
Kaiser, Vera ;
Neuper, Christa ;
Mueller-Putz, Gernot R. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2012, 50 (04) :347-357
[9]   Proposing a Standardized Protocol for Raw Biosignal Transmission [J].
Breitwieser, Christian ;
Daly, Ian ;
Neuper, Christa ;
Mueller-Putz, Gernot R. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (03) :852-859
[10]  
Breitwieser C, 2011, IEEE ENG MED BIO, P6373, DOI 10.1109/IEMBS.2011.6091573