A comparative study of internal fixation and prosthesis replacement for radial head fractures of Mason type III

被引:82
作者
Ruan, Hong-Jiang [1 ]
Fan, Cun-Yi [1 ]
Liu, Jun-Jian [1 ]
Zeng, Bing-fang [1 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 6, Dept Orthopaed Surg, Shanghai 200233, Peoples R China
关键词
ELBOW FRACTURES; ARTHROPLASTY; EXCISION;
D O I
10.1007/s00264-007-0453-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Although several treatment options for radial head fractures are available, no clear solutions exist. In this study we therefore compare open reduction and internal fixation (ORIF) with bipolar radial head prosthesis replacement in treatment of radial head fractures of Mason type III. Cement stem and bipolar radial prosthesis were used to treat 12 fresh cases and two old cases of Mason type III radial head fracture. As a control group, another eight cases of radial head type III fracture were treated with ORIF with cannulated screws and Kirschner (K) wires. The 14 patients who received radial head prosthesis replacement were followed-up for 15.9 months (range 10-27 months). According to elbow functional evaluation criteria by Broberg and Morrey, we found excellent results in nine cases, good in four, and fair in one. Mean follow-up of the eight cases in the ORIF group was 14 months (range 10 21 months), with good results in one case, fair in four, and poor in three. The result was good or excellent in 92.9% of prosthesis replacement patients and in 12.5% of ORIF patients. This difference is statistically significant (P=0.0004; Fisher's exact test). We concluded that bipolar radial head prosthesis replacement is better than ORIF in treatment of Mason type III radial head fracture.
引用
收藏
页码:249 / 253
页数:5
相关论文
共 15 条
[1]  
Bain G I, 2005, J Bone Joint Surg Am, V87 Suppl 1, P136, DOI 10.2106/JBJS.D.02710
[2]  
BERNARD F, 1993, ELBOW ITS DISORDERS
[3]  
Boulas H J, 1998, Chir Main, V17, P314
[4]   Treatment of sequelae of radial head fractures with a bipolar radial head prosthesis - Good outcome after 1-4 years follow-up in 11 patients [J].
Brinkman, JM ;
Rahusen, FTG ;
de Vos, MJ ;
Eygendaal, D .
ACTA ORTHOPAEDICA, 2005, 76 (06) :867-872
[5]   RESULTS OF DELAYED EXCISION OF THE RADIAL HEAD AFTER FRACTURE [J].
BROBERG, MA ;
MORREY, BF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (05) :669-674
[6]   Vitallium radial head prosthesis for acute and chronic elbow fractures and fracture-dislocations involving the radial head [J].
Chapman, Cary B. ;
Su, Brian W. ;
Sinicropi, Stefano M. ;
Bruno, Roderick ;
Strauch, Robert J. ;
Rosenwasser, Melvin P. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2006, 15 (04) :463-473
[7]   Comminuted radial head fractures treated with a modular metallic radial head arthroplasty - Study of outcomes [J].
Grewal, Ruby ;
MacDermid, Joy C. ;
Faber, Kenneth J. ;
Drosdowech, Darren S. ;
King, Graham J. W. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (10) :2192-2200
[8]   The functional outcome with metallic redial head implants in the treatment of unstable elbow fractures: A long-term review [J].
Harrington, IJ ;
Sekyi-Otu, A ;
Barrington, TW ;
Evans, DC ;
Tuli, V .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2001, 50 (01) :46-52
[9]  
Inagaki K, 2002, CLIN ORTHOP RELAT R, P123
[10]   Early excision of the radial head for fracture [J].
Leppilahti, J ;
Jalovaara, P .
INTERNATIONAL ORTHOPAEDICS, 2000, 24 (03) :160-162