Octadecylated silica monolith capillary column with integrated nanoelectrospray ionization emitter for highly efficient proteome analysis

被引:81
作者
Xie, CH [1 ]
Ye, ML [1 ]
Jiang, XG [1 ]
Jin, WH [1 ]
Zou, HF [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Natl Chromatogr Res & Anal Ctr, Dalian 116023, Peoples R China
关键词
D O I
10.1074/mcp.M500272-MCP200
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An improved strategy for the preparation of octadecylated silica monolith capillary column with high homogeneity was proposed. Column performance was evaluated by nanoscale HPLC. The design for constructing an integrated nanoelectrospray emitter on the octadecylated silica monolith capillary column was first introduced. In comparison with the separated configuration where the emitter is connected to monolithic capillary column by the aid of a zero dead volume union, the integrated capillary column has the inherent advantage of the minimized extracolumn volume thus providing improved separation quality. The performance of the integrated monolithic capillary column was evaluated by separation of BSA tryptic digest, and peak capacity of 313 with a 30-cm column was obtained. The high separation performance allowed highly confident identification of 662 distinct proteins through assignment of 1933 unique peptides by analysis of tryptic digest of 0.5 mu g of Saccharomyces cerevisiae proteins. The higher separation efficiency by a 60-cm monolithic capillary column increased the proteome coverage with identification of 1323 proteins through assignment of 5501 unique peptides over 400-min gradient elution.
引用
收藏
页码:454 / 461
页数:8
相关论文
共 32 条
[1]   Mass spectrometry in proteomics [J].
Aebersold, R ;
Goodlett, DR .
CHEMICAL REVIEWS, 2001, 101 (02) :269-295
[2]   Applications of monolithic silica capillary columns in proteomics [J].
Barroso, B ;
Lubda, D ;
Bischoff, R .
JOURNAL OF PROTEOME RESEARCH, 2003, 2 (06) :633-642
[3]   Applications of silica-based monolithic HPLC columns [J].
Cabrera, K .
JOURNAL OF SEPARATION SCIENCE, 2004, 27 (10-11) :843-852
[4]  
Corthals GL, 2000, ELECTROPHORESIS, V21, P1104, DOI 10.1002/(SICI)1522-2683(20000401)21:6<1104::AID-ELPS1104>3.0.CO
[5]  
2-C
[6]   Protein identification using 2D-LC-MS/MS [J].
Delahunty, C ;
Yates, JR .
METHODS, 2005, 35 (03) :248-255
[7]   AN APPROACH TO CORRELATE TANDEM MASS-SPECTRAL DATA OF PEPTIDES WITH AMINO-ACID-SEQUENCES IN A PROTEIN DATABASE [J].
ENG, JK ;
MCCORMACK, AL ;
YATES, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (11) :976-989
[8]  
Giddings J. C., 1991, UNIFIED SEPARATION S, P105
[9]   Capillary columns with in situ formed porous monolithic packing for micro high-performance liquid chromatography and capillary electrochromatography [J].
Gusev, I ;
Huang, X ;
Horváth, C .
JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (01) :273-290
[10]   Evaluation of two-dimensional gel electrophoresis-based proteome analysis technology [J].
Gygi, SP ;
Corthals, GL ;
Zhang, Y ;
Rochon, Y ;
Aebersold, R .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (17) :9390-9395