Facile fabrication of dual-ratiometric electrochemical sensors based on a bare electrode for dual-signal sensing of analytes in electrolyte solution

被引:39
作者
Zhao, Chunqin [1 ]
Jin, Hui [1 ]
Gui, Rijun [1 ]
Wang, Zonghua [1 ]
机构
[1] Qingdao Univ, Shandong Sino Japanese Ctr Collaborat Res Carbon, Growing Base State Key Lab,Collaborat Innovat Ctr, Coll Chem & Chem Engn,Lab Fiber Mat & Modern Text, Qingdao 266071, Peoples R China
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2017年 / 242卷
基金
中国国家自然科学基金;
关键词
Electrochemical sensors; Ratiometric; Bare electrode; Electrolyte solution; Doxorubicin; SENSITIVE DETECTION; DOXORUBICIN HYDROCHLORIDE; DELIVERY-SYSTEM; NANOPARTICLES; APTASENSOR; BIOSENSOR;
D O I
10.1016/j.snb.2016.11.036
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a general strategy to facilely fabricate novel dual-ratiometric (PR) electrochemical sensors (ECSs) was developed. This strategy referred to three types of substances with respective oxidation current peaks at different electric potentials, such as ferrocene (Fc) at 0.15 V, methylene blue (MB) at -0.26 V, and doxorubicin (DOX) at -0:62 V. In a conventional electrolyte solution of phosphate buffered saline (0.01 M, pH 6.5, containing 0.15 M of NaCl), Fc and MB as reference electroactive substances were added and their concentrations in electrolyte solution were fixed to 30 and 4 mu M, respectively. Then, DOX as the analyte was also added into the electrolyte solution to form a homogeneous electrolyte solution. Through directly using a bare glassy carbon electrode as dual-signal sensing platform, square wave voltammetry curves of various electrolyte solutions containing three components of different concentrations were measured, with the each increment of DOX concentration [DOX] from 0.01 to 6 mu M. Ratiometric oxidation current peak intensities (I-DOX/I-Fc or I-DOX/I-MB) nearly linearly enhanced with the increase of [DOX], together with good linear coefficients and low limits of detection (3 nM). The DR-ECSs enabled highly selective and sensitive DOX detection in real human serum and saliva samples with high detection recoveries. These results revealed that this strategy to fabricate novel DR-ECSs was facile and flexible, which would facilitate a further development in the field of electrochemical sensing. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:71 / 78
页数:8
相关论文
共 38 条
[1]   Electrochemical sensors [J].
Bakker, E .
ANALYTICAL CHEMISTRY, 2004, 76 (12) :3285-3298
[2]   ELECTROCHEMICAL-BEHAVIOR OF ADRIAMYCIN AT CARBON PASTE ELECTRODES [J].
BALDWIN, RP ;
PACKETT, D ;
WOODCOCK, TM .
ANALYTICAL CHEMISTRY, 1981, 53 (03) :540-542
[3]   Highly Stretchable Fully-Printed CNT-Based Electrochemical Sensors and Biofuel Cells: Combining Intrinsic and Design-Induced Stretchability [J].
Bandodkar, Amay J. ;
Jeerapan, Itthipon ;
You, Jung-Min ;
Nunez-Flores, Rogelio ;
Wang, Joseph .
NANO LETTERS, 2016, 16 (01) :721-727
[4]   Ratiometric Electrochemical Sensor for Selective Monitoring of Cadmium Ions Using Biomolecular Recognition [J].
Chai, Xiaolan ;
Zhang, Limin ;
Tian, Yang .
ANALYTICAL CHEMISTRY, 2014, 86 (21) :10668-10673
[5]   Graphene Oxide: Preparation, Functionalization, and Electrochemical Applications [J].
Chen, Da ;
Feng, Hongbin ;
Li, Jinghong .
CHEMICAL REVIEWS, 2012, 112 (11) :6027-6053
[6]   Reagentless, Ratiometric Electrochemical DNA Sensors with Improved Robustness and Reproducibility [J].
Du, Yan ;
Lim, Byung Joon ;
Li, Bingling ;
Jiang, Yu Sherry ;
Sessler, Jonathan L. ;
Ellington, Andrew D. .
ANALYTICAL CHEMISTRY, 2014, 86 (15) :8010-8016
[7]   A Dual-Color Luminescent Localized Drug Delivery System with Ratiometric-Monitored Doxorubicin Release Functionalities [J].
Fu, Yike ;
Chen, Xiaoyi ;
Mou, Xiaozhou ;
Ren, Zhaohui ;
Li, Xiang ;
Han, Gaorong .
ACS BIOMATERIALS SCIENCE & ENGINEERING, 2016, 2 (04) :652-661
[8]   Target catalyzed hairpin assembly for constructing a ratiometric electrochemical aptasensor [J].
Gao, Fenglei ;
Qian, Yong ;
Zhang, Lei ;
Dai, Shizhen ;
Lan, Yanfei ;
Zhang, Yu ;
Du, Lili ;
Tang, Daoquan .
BIOSENSORS & BIOELECTRONICS, 2015, 71 :158-163
[9]   Ratiometric electrochemical detection of alkaline phosphatase [J].
Goggins, Sean ;
Naz, Christophe ;
Marsh, Barrie J. ;
Frost, Christopher G. .
CHEMICAL COMMUNICATIONS, 2015, 51 (03) :561-564
[10]   Electrochemically oxidized multiwalled carbon nanotube/glassy carbon electrode as a probe for simultaneous determination of dopamine and doxorubicin in biological samples [J].
Haghshenas, Esmaeel ;
Madrakian, Tayyebeh ;
Afkhami, Abbas .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (10) :2577-2586