A new frosting map of variable-frequency air source heat pump in severe cold region considering the variation of heating load

被引:36
作者
Wei, Wenzhe [1 ]
Ni, Long [1 ]
Li, Shuyi [1 ]
Wang, Wei [2 ]
Yao, Yang [1 ]
Xu, Laifu [3 ]
Yang, Yahua [3 ]
机构
[1] Harbin Inst Technol, Sch Architecture, Key Lab Cold Reg Urban & Rural Human Settlement E, Minist Ind & Informat Technol, Harbin, Peoples R China
[2] Beijing Univ Technol, Coll Architecture & Civil Engn, Dept Bldg Environm & Facil Engn, 100 Pingleyuan, Beijing 100124, Peoples R China
[3] Nanjing TICA Climate Solut CO Ltd, Nanjing, Peoples R China
基金
中国国家自然科学基金;
关键词
Air source heat pump; Frosting map; Heating load; Severe cold region; Variable-frequency; VAPOR INJECTION; PERFORMANCE; SYSTEM; EXCHANGER; TEMPERATURE; OPTIMIZATION; GROWTH;
D O I
10.1016/j.renene.2020.07.087
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
During experiments on investigating the application feasibility of variable-frequency air source heat pump with vapor injection (ASHPVI) in severe cold region, it was found its frosting performance varied significantly from that in former investigations, e.g. in a severe frosting condition (0 degrees C, 80%), the experimental unit was frost-free. To investigate the frosting characteristics of variable-frequency ASHPVI for space heating in severe cold region, a test rig was built and used to supply heating for a lab in two heating seasons. A new frosting map was developed through summarizing its running performance under frosting condition. Results showed the frosting map of variable-frequency ASHPVI was affected by heating load. Owing to the consideration of heating load, the critical relative humidity decreased from 80.60% to 62.75% when outdoor temperature (OT) dropped from 1.0 degrees C to -26.5 degrees C, opposite to the change trend in former investigations. Besides, compared with values obtained in cold region, the upper and lower limits of OT of frosting region in severe cold region were both lower, and its critical relative humidity was higher. Moreover, the highest frosting speed appeared at OT of approximately -10 degrees C in severe cold region, but not at 0 degrees C as previously thought. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页码:184 / 199
页数:16
相关论文
共 45 条
[31]   Technical, economic and environmental investigation on heating performance of quasi-two stage compression air source heat pump in severe cold region [J].
Wei, Wenzhe ;
Ni, Long ;
Zhou, Chaohui ;
Wang, Wei ;
Xu, Laifu ;
Yang, Yahua ;
Yao, Yang .
ENERGY AND BUILDINGS, 2020, 223
[32]   Performance analysis of a quasi-two stage compression air source heat pump in severe cold region with a new control strategy [J].
Wei, Wenzhe ;
Ni, Long ;
Zhou, Chaohui ;
Yao, Yang ;
Xu, Laifu ;
Yang, Yahua .
APPLIED THERMAL ENGINEERING, 2020, 174
[33]   Experimental and theoretical investigation on defrosting characteristics of a multi-split air source heat pump with vapor injection [J].
Wei, Wenzhe ;
Ni, Long ;
Wang, Wei ;
Yao, Yang .
ENERGY AND BUILDINGS, 2020, 217
[34]   Application characteristics of variable refrigerant flow heat pump system with vapor injection in severe cold region [J].
Wei, Wenzhe ;
Ni, Long ;
Xu, Laifu ;
Yang, Yahua ;
Yao, Yang .
ENERGY AND BUILDINGS, 2020, 211
[35]   Techno-economic analysis of air source absorption heat pump: Improving economy from a design perspective [J].
Wu, Wei ;
Wang, Baolong ;
Shi, Wenxing ;
Li, Xianting .
ENERGY AND BUILDINGS, 2014, 81 :200-210
[36]   Annual performance analysis of an air source heat pump water heater using a new eco-friendly refrigerant mixture as an alternative to R134a [J].
Xiao, Biao ;
Chang, Huawei ;
He, Lin ;
Zhao, Shunan ;
Shu, Shuiming .
RENEWABLE ENERGY, 2020, 147 :2013-2023
[37]   Feasibility and performance study on hybrid air source heat pump system for ultra-low energy building in severe cold region of China [J].
Xu, Wei ;
Liu, Changping ;
Li, Angui ;
Li, Ji ;
Qiao, Biao .
RENEWABLE ENERGY, 2020, 146 :2124-2133
[38]   A study on the performance of the airside heat exchanger under frosting in an air source heat pump water heater/chiller unit [J].
Yao, Y ;
Jiang, YQ ;
Deng, SM ;
Ma, ZL .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (17-18) :3745-3756
[39]   Performance prediction of a fin-and-tube heat exchanger considering air-flow reduction due to the frost accumulation [J].
Ye, Huee-Youl ;
Lee, Kwan-Soo .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 67 :225-233
[40]   A Review on Recent Development of Cooling Technologies for Photovoltaic Modules [J].
Zhang, Chunxiao ;
Shen, Chao ;
Wei, Shen ;
Wang, Yuan ;
Lv, Guoquan ;
Sun, Cheng .
JOURNAL OF THERMAL SCIENCE, 2020, 29 (06) :1410-1430