A new frosting map of variable-frequency air source heat pump in severe cold region considering the variation of heating load

被引:33
作者
Wei, Wenzhe [1 ]
Ni, Long [1 ]
Li, Shuyi [1 ]
Wang, Wei [2 ]
Yao, Yang [1 ]
Xu, Laifu [3 ]
Yang, Yahua [3 ]
机构
[1] Harbin Inst Technol, Sch Architecture, Key Lab Cold Reg Urban & Rural Human Settlement E, Minist Ind & Informat Technol, Harbin, Peoples R China
[2] Beijing Univ Technol, Coll Architecture & Civil Engn, Dept Bldg Environm & Facil Engn, 100 Pingleyuan, Beijing 100124, Peoples R China
[3] Nanjing TICA Climate Solut CO Ltd, Nanjing, Peoples R China
基金
中国国家自然科学基金;
关键词
Air source heat pump; Frosting map; Heating load; Severe cold region; Variable-frequency; VAPOR INJECTION; PERFORMANCE; SYSTEM; EXCHANGER; TEMPERATURE; OPTIMIZATION; GROWTH;
D O I
10.1016/j.renene.2020.07.087
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
During experiments on investigating the application feasibility of variable-frequency air source heat pump with vapor injection (ASHPVI) in severe cold region, it was found its frosting performance varied significantly from that in former investigations, e.g. in a severe frosting condition (0 degrees C, 80%), the experimental unit was frost-free. To investigate the frosting characteristics of variable-frequency ASHPVI for space heating in severe cold region, a test rig was built and used to supply heating for a lab in two heating seasons. A new frosting map was developed through summarizing its running performance under frosting condition. Results showed the frosting map of variable-frequency ASHPVI was affected by heating load. Owing to the consideration of heating load, the critical relative humidity decreased from 80.60% to 62.75% when outdoor temperature (OT) dropped from 1.0 degrees C to -26.5 degrees C, opposite to the change trend in former investigations. Besides, compared with values obtained in cold region, the upper and lower limits of OT of frosting region in severe cold region were both lower, and its critical relative humidity was higher. Moreover, the highest frosting speed appeared at OT of approximately -10 degrees C in severe cold region, but not at 0 degrees C as previously thought. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页码:184 / 199
页数:16
相关论文
共 45 条
  • [1] Adachi M., 1975, Refrigeration, V50, P818
  • [2] Review of defrosting methods
    Amer, Mohammed
    Wang, Chi-Chuan
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 73 : 53 - 74
  • [3] Performance comparison between R410A and R32 multi-heat pumps with a sub-cooler vapor injection in the heating and cooling modes
    Cho, Ii Yong
    Seo, HyeongJoon
    Kim, Dongwoo
    Kim, Yongchan
    [J]. ENERGY, 2016, 112 : 179 - 187
  • [4] Defrosting method adopting dual hot gas bypass for an air-to-air heat pump
    Choi, Hwan-Jong
    Kim, Byung-Soon
    Kang, Donghoon
    Kim, Kyung Chun
    [J]. APPLIED ENERGY, 2011, 88 (12) : 4544 - 4555
  • [5] Solar heating and cooling: Present and future development
    Ge, T. S.
    Wang, R. Z.
    Xu, Z. Y.
    Pan, Q. W.
    Du, S.
    Chen, X. M.
    Ma, T.
    Wu, X. N.
    Sun, X. L.
    Chen, J. F.
    [J]. RENEWABLE ENERGY, 2018, 126 : 1126 - 1140
  • [6] Experimental study on frost growth and dynamic performance of air source heat pump system
    Guo, Xian-Min
    Chen, Yi-Guang
    Wang, Wei-Hua
    Chen, Chun-Zheng
    [J]. APPLIED THERMAL ENGINEERING, 2008, 28 (17-18) : 2267 - 2278
  • [7] Frosting characteristics of fin-tube heat exchanger at temperature range of-18 to 6 °C of a cascade heat pump
    Han, Xing
    Fan, Wei
    Qu, Minglu
    Chen, Jianbo
    Chen, Qiuhuo
    [J]. APPLIED THERMAL ENGINEERING, 2014, 67 (1-2) : 131 - 136
  • [8] Numerical research on coupling performance of inter-stage parameters for two-stage compression system with injection
    Jin, Xu
    Zhang, Kuo
    Liu, Zhongyan
    Li, Xiaoyi
    Jiang, Shuang
    [J]. APPLIED THERMAL ENGINEERING, 2018, 128 : 1430 - 1445
  • [9] PERFORMANCE OF FINNED-TUBE HEAT-EXCHANGERS UNDER FROSTING CONDITIONS .1. SIMULATION-MODEL
    KONDEPUDI, SN
    ONEAL, DL
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1993, 16 (03): : 175 - 180
  • [10] A field study on the effects of outdoor coil fouling at different ambient air temperatures on the operating performances of a space cooling ASHP unit
    Lin, Yao
    Wang, Wei
    Sun, Yuying
    Liu, Jingdong
    Deng, Shiming
    [J]. ENERGY AND BUILDINGS, 2019, 183 : 639 - 649