Multicenter comparison study of current methods to measure 25-hydroxyvitamin D in serum

被引:73
作者
Janssen, Marcel J. W. [1 ]
Wielders, Jos P. M. [2 ]
Bekker, Corinne C. [1 ]
Boesten, Lianne S. M. [3 ]
Buijs, Madelon M. [4 ]
Heijboer, Annemieke C. [5 ]
van der Horst, Frans A. L. [6 ]
Loupatty, Ference J. [7 ]
van den Ouweland, Johannes M. W. [8 ]
机构
[1] VieCuri Med Ctr, Lab Clin Chem & Haematol, NL-5900 BX Venlo, Netherlands
[2] Meander Med Ctr, Dept Clin Chem, Amersfoort, Netherlands
[3] Ijsselland Hosp, Gen Clin Lab, Capelle aan den IJssel, Netherlands
[4] Medial Diagnost Ctr, Hoofddorp, Netherlands
[5] Vrije Univ Amsterdam Med Ctr, Endocrine Lab, Dept Clin Chem, Amsterdam, Netherlands
[6] Reinier de Graaf Groep, Dept Clin Chem, Delft, Netherlands
[7] Onze Lieve Vrouw Hosp, Dept Clin Chem, Amsterdam, Netherlands
[8] Canisius Wilhelmina Hosp, Dept Clin Chem, Nijmegen, Netherlands
关键词
25-Hydroxyvitamin [25(OH)D; Method comparison; SRM972; NIST; DEQAS; TANDEM MASS-SPECTROMETRY; D ASSAYS; ACCURACY; D-3; INFANTS;
D O I
10.1016/j.steroids.2012.07.013
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Objectives: Measurement of serum 25-hydroxyvitamin D [25(OH)D] is generally considered to be a reliable indicator of vitamin D status. The recent increase in diversity of 25(OH)D assays prompted us to evaluate the performance of chromatographic methods (two in-house ID-LC-MS/MS and HPLC (ClinRep, Recipe)), a protein binding method (Cobas-25(OH)D-total, Roche) and immunochemical methods (Liaison and RIA (Diasorin), iSYS (IDS), ADVIA Centaur (Siemens), and Architect i1000 and i2000 (Abbott)). Methods: Blood was drawn from randomly selected outpatients (N = 60) at one site after informed consent. DEQAS and SRM 972 samples were obtained from the scheme organizer and NIST, respectively. Serum aliquots were prepared, frozen and transported to participating centers. Method comparison was performed according to CLSI-EP9 specifications. Results: With these patient samples, and in comparison with ID-LC-MS/MS, Deming regression parameters slope, intercept and R were found to be within the ranges [0.57-1.07], [-1.7 to 6.9 nmol/L] and [0.88-0.98], respectively. 25(OH)D2 in DEQAS and SRM samples was fully recognized by chromatographic methods, but only partially by protein binding and immunochemical methods. Chromatographic methods, and to a lesser extent the protein binding assay, showed cross-reactivity with 3-epi-25(OH)D3. Agreement of 25(OH)D assays to ID-LC-MS/MS in sorting patients into distinct 25(OH)D categories varied between 53% and 88%. Conclusions: Significant bias exists between ID-LC-MS/MS and man, but not all, other 25(OH)D assays. The variable response among different assays for 25(OH)D metabolites impedes the use of uniform cutoff values for defining vitamin D status. Our results indicate the need towards further standardizing assays for 25(OH)D measurement. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:1366 / 1372
页数:7
相关论文
共 17 条
[1]   Assay variation confounds the diagnosis of hypovitaminosis D: A call for standardization [J].
Binkley, N ;
Krueger, D ;
Cowgill, CS ;
Plum, L ;
Lake, E ;
Hansen, KE ;
DeLuca, HF ;
Drezner, MK .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2004, 89 (07) :3152-3157
[2]   Current status of clinical 25-hydroxyvitamin D measurement: An assessment of between-laboratory agreement [J].
Binkley, Neil ;
Krueger, Diane C. ;
Morgan, Sarah ;
Wiebe, Donald .
CLINICA CHIMICA ACTA, 2010, 411 (23-24) :1976-1982
[3]  
Carter GD, 2011, CURR DRUG TARGETS, V12, P19
[4]   Cross-reactivity of 25-hydroxy vitamin D2 from different commercial immunoassays for 25-hydroxy vitamin D: an evaluation without spiked samples [J].
Cavalier, Etienne ;
Wallace, A. Michael ;
Carlisi, Agnes ;
Chapelle, Jean-Paul ;
Delanaye, Pierre ;
Souberbielle, Jean-Claude .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (03) :555-558
[5]   Evaluation of 25-hydroxy vitamin D assay on the immunodiagnostic systems iSYS analyser [J].
Cluse, Zee N. ;
Fudge, Andrew N. ;
Whiting, Malcolm J. ;
McWhinney, Brett ;
Parkinson, Ian ;
O'Loughlin, Peter D. .
ANNALS OF CLINICAL BIOCHEMISTRY, 2012, 49 :159-165
[6]   State-of-the-Art Vitamin D Assays: A Comparison of Automated Immunoassays with Liquid Chromatography-Tandem Mass Spectrometry Methods [J].
Farrell, Christopher-John L. ;
Martin, Steven ;
McWhinney, Brett ;
Straub, Isabella ;
Williams, Paul ;
Herrmann, Markus .
CLINICAL CHEMISTRY, 2012, 58 (03) :531-542
[7]   Accuracy of 6 Routine 25-Hydroxyvitamin D Assays: Influence of Vitamin D Binding Protein Concentration [J].
Heijboer, Annemieke C. ;
Blankenstein, Marinus A. ;
Kema, Ido P. ;
Buijs, Madelon M. .
CLINICAL CHEMISTRY, 2012, 58 (03) :543-548
[8]  
Holick MF, 2011, J CLIN ENDOCR METAB, V96, P1911, DOI [10.1210/jc.2011-0385, 10.1210/jc.2011-1193]
[9]   Exogenous versus endogenous recovery of 25-hydroxyvitamins D2 and D3 in human samples using high-performance liquid chromatography and the DiaSorin LIAISON Total-D Assay [J].
Horst, Ronald L. .
JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2010, 121 (1-2) :180-182
[10]   The 2011 Report on Dietary Reference Intakes for Calcium and Vitamin D from the Institute of Medicine: What Clinicians Need to Know [J].
Ross, A. Catharine ;
Manson, JoAnn E. ;
Abrams, Steven A. ;
Aloia, John F. ;
Brannon, Patsy M. ;
Clinton, Steven K. ;
Durazo-Arvizu, Ramon A. ;
Gallagher, J. Christopher ;
Gallo, Richard L. ;
Jones, Glenville ;
Kovacs, Christopher S. ;
Mayne, Susan T. ;
Rosen, Clifford J. ;
Shapses, Sue A. .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2011, 96 (01) :53-58