Studying signal collection in the punch-through protection area of a silicon micro-strip sensor using a micro-focused X-ray beam

被引:0
|
作者
Poley, L. [1 ]
Bates, R. [2 ]
Bloch, I. [1 ]
Blue, A. J. [2 ]
Fadeyev, V. [3 ]
Meng, L. [4 ]
Rehnisch, L. [5 ]
Stegler, M. [1 ]
Unno, Y. [6 ]
机构
[1] Deutsch Elektronen Synchrotron DESY, D-15738 Zeuthen, Germany
[2] Univ Glasgow, SUPA Sch Phys & Astron, Glasgow G12 8QQ, Lanark, Scotland
[3] Univ Calif Santa Cruz, SCIPP, Santa Cruz, CA 95064 USA
[4] Univ Liverpool, Oliver Lodge Lab, Liverpool L69 3BX, Merseyside, England
[5] Humboldt Univ, Inst Phys, D-12489 Berlin, Germany
[6] High Energy Accelerator Res Org KEK, Inst Particle & Nucl Study, 1-1 Oho, Tsukuba, Ibaraki 3050801, Japan
基金
英国科学技术设施理事会;
关键词
ATLAS; Silicon strip sensors; Radiation damage; Punch-through protection; ACCELERATOR;
D O I
10.1016/j.nima.2018.06.085
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
For the Phase-II Upgrade of the ATLAS detector (The ATLAS Collaboration, 2008 [1]), a new, all-silicon tracker will be constructed in order to cope with the increased track density and radiation level of the High-Luminosity Large Hadron Collider. While silicon strip sensors are designed to minimise the fraction of dead material and maximise the active area of a sensor, concessions must be made to the requirements of operating a sensor in a particle physics detector. Sensor geometry features like the punch-through protection deviate from the standard sensor architecture and thereby affect the charge collection in that area. In order to study the signal collection of n(+)-p(-)-p(+) silicon strip sensors over their punch-through-protection area, ATLAS silicon strip sensors were scanned with a micro-focused X-ray beam at the Diamond Light Source. Due to the highly focused X-ray beam (2 x 3 mu m(2)) and the short average path length of an electron after interaction with an X-ray photon (<= 2 mu m), local signal collection in different sensor areas can be studied with high resolution. This study presents results of high resolution 2D-scans of the punch-through protection region of ATLAS silicon micro-strip sensors, showing how far the strip signal collection area extends towards the bias ring and how the region is affected by radiation damage.
引用
收藏
页码:116 / 119
页数:4
相关论文
共 30 条
  • [21] Chemical state mapping of simulant Chernobyl lava-like fuel containing material using micro-focused synchrotron X-ray spectroscopy
    Ding, Hao
    Wilkins, Malin C. Dixon
    Mottram, Lucy M.
    Blackburn, Lewis R.
    Grolimund, Daniel
    Tappero, Ryan
    Nicholas, Sarah L.
    Sun, Shikuan
    Corkhill, Claire L.
    Hyatt, Neil C.
    JOURNAL OF SYNCHROTRON RADIATION, 2021, 28 : 1672 - 1683
  • [22] Probing Defects In a Small Pixellated CdTe Sensor Using an Inclined Mono Energetic X-Ray Micro Beam
    Frojdh, Erik
    Frojdh, C.
    Gimenez, E. N.
    Krapoh
    Maneuski, D.
    Norlin, B.
    O'Shea, V.
    Wilhem, H.
    Tartoni, N.
    Thungstrom, G.
    Zain, R. M.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 4233 - 4236
  • [23] Probing Defects in a Small Pixellated CdTe Sensor Using an Inclined Mono Energetic X-Ray Micro Beam
    Froejdh, Erik
    Froejdh, C.
    Gimenez, E. N.
    Krapohl, D.
    Maneuski, D.
    Norlin, B.
    O'Shea, V.
    Wilhelm, H.
    Tartoni, N.
    Thungstroem, G.
    Zain, R. M.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (04) : 2864 - 2869
  • [24] Laboratory-based micro-X-ray fluorescence setup using a von Hamos crystal spectrometer and a focused beam X-ray tube
    Kayser, Y.
    Blachucki, W.
    Dousse, J. -Cl.
    Hoszowska, J.
    Neff, M.
    Romano, V.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (04):
  • [25] Pore-scale contact angle measurements of CO2-brine-glass beads system using micro-focused X-ray computed tomography
    Lv, Pengfei
    Liu, Yu
    Jiang, Lanlan
    Song, Yongchen
    Huang, Qingxun
    MICRO & NANO LETTERS, 2016, 11 (09): : 524 - 527
  • [26] Upgrade of Beamline BL25SU for Soft X-ray Imaging and Spectroscopy of Solid Using Nano- and Micro-focused Beams at SPring-8
    Senba, Yasunori
    Ohashi, Haruhiko
    Kotani, Yoshinori
    Nakamura, Tetsuya
    Muro, Takayuki
    Ohkochi, Takuo
    Tsuji, Naruki
    Kishimoto, Hikaru
    Miura, Takanori
    Tanaka, Masayuki
    Higashiyama, Masahiro
    Takahashi, Sunao
    Ishizawa, Yasuhide
    Matsushita, Tomohiro
    Furukawa, Yukito
    Ohata, Toru
    Nariyama, Nobuteru
    Takeshita, Kunikazu
    Kinoshita, Toyohiko
    Fujiwara, Akihiko
    Takata, Masaki
    Goto, Shunji
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2015), 2016, 1741
  • [27] Palm-top size X-ray microanalyzer using a pyroelectric focused electron beam with 100-micro-meter diameter
    Kawai, Jun
    Ohtani, Issei
    Imanishi, Akira
    Imashuku, Susumu
    22ND INTERNATIONAL CONGRESS ON X-RAY OPTICS AND MICROANALYSIS, 2014, 499
  • [28] Study of Stresses and Plasticity in Through-Silicon Via Structures for 3D Interconnects by X-Ray Micro-Beam Diffraction
    Jiang, Tengfei
    Wu, Chenglin
    Tamura, Nobumichi
    Kunz, Martin
    Kim, Byoung Gyu
    Son, Ho-Young
    Suh, Min-Suk
    Im, Jay
    Huang, Rui
    Ho, Paul S.
    IEEE TRANSACTIONS ON DEVICE AND MATERIALS RELIABILITY, 2014, 14 (02) : 698 - 703
  • [29] Resolving macro- and micro-porous layer interaction in polymer electrolyte fuel cells using focused ion beam and X-ray computed tomography
    Wargo, E. A.
    Schulz, V. P.
    Cecen, A.
    Kalidindi, S. R.
    Kumbur, E. C.
    ELECTROCHIMICA ACTA, 2013, 87 : 201 - 212
  • [30] Observation of nano-indent induced strain fields and dislocation generation in silicon wafers using micro-Raman spectroscopy and white beam X-ray topography
    Allen, D.
    Wittge, J.
    Zlotos, A.
    Gorostegui-Colinas, E.
    Garagorri, J.
    McNally, P. J.
    Danilewsky, A. N.
    Elizalde, M. R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (3-4): : 383 - 387