Evaluation of equine urine reactivity towards phase II metabolites of 17-hydroxy steroids by liquid chromatography/tandem mass spectrometry

被引:12
作者
Fidani, M. [2 ]
Gamberini, M. C. [3 ]
Pasello, E. [2 ]
Palazzoli, F. [3 ]
De Luliis, P. [2 ]
Montana, M. [2 ]
Arioli, F. [1 ]
机构
[1] Univ Milan, Dept Vet Sci & Technol Food Safety, I-20133 Milan, Italy
[2] UNIRE Lab Srl, I-20019 Settimo Milanese, MI, Italy
[3] Univ Modena, Inst Pharm, Dept Pharmaceut Sci, I-41100 Modena, Italy
关键词
HORSE URINE; ANABOLIC-STEROIDS; TESTOSTERONE; STABILITY; QUANTIFICATION; GLUCURONIDES; PROFILE;
D O I
10.1002/rcm.3858
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Proper storage conditions of biological samples are fundamental to avoid microbiological contamination that can cause chemical modifications of the target analytes. A simple liquid chromatography/tandem mass spectrometry (LC/MS/MS) method through direct injection of diluted samples, without prior extraction, was used to evaluate the stability of phase II metabolites of boldenone and testosterone (glucuronides and sulphates) in intentionally poorly stored equine urine samples. We also considered the stability of some deuterated conjugated steroids generally used as internal standards, such as deuterated testosterone and epitestosterone glucuronides, and deuterated boldenone and testosterone sulphates. The urines were kept for 1 day at room temperature, to mimic poor storage conditions, then spiked with the above steroids and kept at different temperatures (-18 degrees C, 4 degrees C, room temperature). It has been possible to confirm the instability of glucuronide compounds when added to poorly stored equine urine samples. In particular, both 17 beta- and 17 alpha-glucuronide steroids were exposed to hydrolysis leading to non-conjugated steroids. Only 17 beta-hydroxy steroids were exposed to oxidation to their keto derivatives whereas the 17 alpha-hydroxy steroids were highly stable. The sulphate compounds were completely stable. The deuterated compounds underwent the same behaviour as the unlabelled compounds. The transformations were observed in urine samples kept at room temperature and at a temperature of 4 degrees C (at a slower rate). No modifications were observed in frozen urine samples. In the light of the latter results, the immediate freezing at -18 degrees C of the collected samples and their instant analysis after thawing is the proposed procedure for preventing the transformations that occur in urine, usually due to microbiological contamination. Copyright (C) 2008 John Wiley & Sons, Ltd.
引用
收藏
页码:65 / 76
页数:12
相关论文
共 24 条
[11]   Rapid test by liquid chromatography/tandem mass spectrometry to evaluate equine urine reactivity towards 17β-OH steroids [J].
Fidani, Marco ;
Casagni, Eleonora ;
Montana, Marco ;
Pasello, Emanuela ;
Pecoraro, Chiara ;
Gambaro, Veniero .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (16) :2441-2446
[12]   Detection, quantification and confirmation of anabolic steroids in equine plasma by liquid chromatography and tandem mass spectrometry [J].
Guan, FY ;
Uboh, CE ;
Soma, LR ;
Luo, Y ;
Rudy, J ;
Tobin, T .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 829 (1-2) :56-68
[13]  
Houghton E., 1992, Proceedings of the 9th International Conference of Racing Analysts and Veterinarians, P3
[14]   Stability studies of testosterone and epitestosterone glucuronides in urine [J].
Jiménez, C ;
de la Torre, R ;
Segura, J ;
Ventura, R .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (05) :858-864
[15]  
Kicman AT, 2002, CLIN CHEM, V48, P1799
[16]   Feasibility of a liquid-phase microextraction sample clean-up and liquid chromatographic/mass spectrometric screening method for selected anabolic steroid glucuronides in biological samples [J].
Kuuranne, T ;
Kotiaho, T ;
Pedersen-Bjergaard, S ;
Rasmussen, KE ;
Leinonen, A ;
Westwood, S ;
Kostiainen, R .
JOURNAL OF MASS SPECTROMETRY, 2003, 38 (01) :16-26
[17]   Direct detection of boldenone sulfate and glucuronide conjugates in horse urine by ion trap liquid chromatography-mass spectrometry [J].
Pu, F ;
McKinney, AR ;
Stenhouse, AM ;
Suann, CJ ;
McLeod, MD .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 813 (1-2) :241-246
[18]  
ROBERTSON MD, 1995, J FORENSIC SCI, V40, P382
[19]  
Robertson MD, 1998, J FORENSIC SCI, V43, P5
[20]   Quantitation of 17β-nandrolone metabolites in boar and horse urine by gas chromatography-mass spectrometry [J].
Roig, Meritxell ;
Segura, Jordi ;
Ventura, Rosa .
ANALYTICA CHIMICA ACTA, 2007, 586 (1-2) :184-195