The use of entangled-photon imaging in optical biopsy: a feasibility study

被引:0
作者
Goldfain, E [1 ]
机构
[1] Welch Allyn Inc, Med R&D, Skaneateles Falls, NY 13153 USA
来源
18TH CONGRESS OF THE INTERNATIONAL COMMISSION FOR OPTICS: OPTICS FOR THE NEXT MILLENNIUM, TECHNICAL DIGEST | 1999年 / 3749卷
关键词
D O I
10.1117/12.354947
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We examine a novel diagnostic method suitable for optical biopsy, i.e., the noninvasive in vivo detection of malignant lesions in human tissue. Entangled-photon imaging is an emerging technology based upon the use of non-classical sources of light such as optical parametric oscillators (OPO). These sources generate above-threshold signal and idler beams that have intensity fluctuations highly correlated in space and time (twin beams)(1,2). It has been shown that low-intensity OPO's make possible high sensitivity absorption measurements of weak targets, below the shot-noise limit(3,4). The direct use of this technology for optical biopsy is severely restricted by the large amount of scattering noise associated with light-tissue interaction. We report what is, to our knowledge, the first feasibility study on a differential wavelength, OPO-based setup targeted for mammography. Constraints related to the entanglement time, OPO selection and background suppression are analyzed. The paper concludes with a review of future developments and challenges.
引用
收藏
页码:671 / 672
页数:2
相关论文
共 8 条
  • [1] Evaluation of the temporally extrapolated absorbance method for dual-wavelength imaging through tissuelike scattering media
    Hebden, JC
    Tziraki, M
    Delpy, DT
    [J]. APPLIED OPTICS, 1997, 36 (16): : 3802 - 3810
  • [2] OBSERVATION OF QUANTUM NOISE-REDUCTION ON TWIN LASER-BEAMS
    HEIDMANN, A
    HOROWICZ, RJ
    REYNAUD, S
    GIACOBINO, E
    FABRE, C
    CAMY, G
    [J]. PHYSICAL REVIEW LETTERS, 1987, 59 (22) : 2555 - 2557
  • [3] SPATIOTEMPORAL COHERENCE PROPERTIES OF ENTANGLED LIGHT-BEAMS GENERATED BY PARAMETRIC DOWN-CONVERSION
    JOOBEUR, A
    SALEH, BEA
    TEICH, MC
    [J]. PHYSICAL REVIEW A, 1994, 50 (04): : 3349 - 3361
  • [4] Coherence properties of entangled light beams generated by parametric down-conversion: Theory and experiment
    Joobeur, A
    Saleh, BEA
    Larchuk, TS
    Teich, MC
    [J]. PHYSICAL REVIEW A, 1996, 53 (06): : 4360 - 4371
  • [5] Sub-shot-noise laser Doppler anemometry with amplitude-squeezed light
    Li, YQ
    Lynam, P
    Xiao, M
    Edwards, PJ
    [J]. PHYSICAL REVIEW LETTERS, 1997, 78 (16) : 3105 - 3108
  • [6] Sub-shot-noise high-sensitivity spectroscopy with optical parametric oscillator twin beams
    Ribeiro, PHS
    Schwob, C
    Maitre, A
    Fabre, C
    [J]. OPTICS LETTERS, 1997, 22 (24) : 1893 - 1895
  • [7] Entangled-photon virtual-state spectroscopy
    Saleh, BEA
    Jost, BM
    Fei, HB
    Teich, MC
    [J]. PHYSICAL REVIEW LETTERS, 1998, 80 (16) : 3483 - 3486
  • [8] Statistical properties of the penetration of photons into a semi-infinite turbid medium: a random-walk analysis
    Weiss, GH
    [J]. APPLIED OPTICS, 1998, 37 (16) : 3558 - 3563