Total elbow arthroplasty: Influence of implant positioning on functional outcomes

被引:14
作者
Lenoir, H. [1 ]
Micallef, P. [2 ]
Djerbi, I. [1 ]
Waitzenegger, T. [1 ]
Lazerges, C. [1 ]
Chammas, M. [1 ]
Coulet, B. [1 ]
机构
[1] CHU Lapeyronie, Hand & Upper Limb Surg Unit, Lapeyronie Teaching Hosp, F-34295 Montpellier 5, France
[2] Univ Montpellier I, EA 2991, STAPS Sch Sports Sci, Res Lab Movement Hlth M2H, Montpellier, France
关键词
Total elbow arthroplasty; Positioning; Rotation axis; Anatomy; RHEUMATOID-ARTHRITIS; PROXIMAL ULNA; DISTAL HUMERUS; FOLLOW-UP; KINEMATICS; REPLACEMENT; PROSTHESIS; ALIGNMENT; COMPLICATIONS; FIXATION;
D O I
10.1016/j.otsr.2015.07.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Restoring the axis of rotation is often considered crucial to achieving good functional outcomes of total elbow arthroplasty. The objective of this work was to evaluate whether variations in implant positioning correlated with clinical outcomes. Hypothesis: Clinical outcomes are dictated by the quality of implant positioning. Material and methods: A retrospective review was conducted of data from 25 patients (26 elbows). Function was assessed using a pain score, the Disabilities of the Arm, Shoulder, and Hand (DASH) Score, and the Mayo Elbow Performance Score (MEPS). The patients also underwent a clinical evaluation for measurements of motion range and flexion/extension strength. Position of the humeral and ulnar implants was assessed by computed tomography with reconstruction using OsiriX software. Indices reflecting anterior offset, lateral offset, valgus, height, and rotation were computed by subtracting the ulnar value of each of these variables from the corresponding humeral value. These indices provided a quantitative assessment of whether position errors for the two components had additive effects or, on the contrary, counterbalanced each other. Elbows with prosthetic loosening or extensive epiphyseal destruction were excluded. Results: Of the 26 elbows, 5 were excluded. In the remaining 21 elbows, the discrepancy between the humeral and ulnar lateral offsets was significantly associated with pain intensity (P <= 0.05) and the MEPS (P <= 0.05). Anterior position of the ulna relative to the humerus was associated with decreased extension strength (P <= 0.05) and worse results for all functional parameters (P <= 0.05). Discussion: In the absence of loosening, positioning errors seem to adversely affect functional outcomes, probably by placing inappropriate stress on the soft tissues. (C) 2015 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:721 / 727
页数:7
相关论文
共 49 条
  • [1] A morphometric study on the humerus for intramedullary fixation
    Akpinar, F
    Aydinlioglu, A
    Tosun, N
    Dogun, A
    Tuncay, I
    Ünal, Ö
    [J]. TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 2003, 199 (01) : 35 - 42
  • [2] Kinematics and constraint of total elbow arthroplasty
    An, KN
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2005, 14 (01) : 168S - 173S
  • [3] Morphologic analysis of the distal humerus with special interest in elbow implant sizing and alignment
    Brownhill, James R.
    King, Graham J. W.
    Johnson, James A.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2007, 16 (03) : 126S - 132S
  • [4] The effect of implant malalignment on joint loading in total elbow arthroplasty: an in vitro study
    Brownhill, James R.
    Pollock, J. W.
    Ferreira, Louis M.
    Johnson, James A.
    King, Graham J. W.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (08) : 1032 - 1038
  • [5] Total elbow arthroplasty in rheumatoid arthritis - 20 GSBIII prostheses followed 2-5 years
    Canovas, F
    Ledoux, D
    Bonnel, F
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1999, 70 (06): : 564 - 568
  • [6] GSB III total elbow replacement in rheumatoid arthritis
    Cesar, M.
    Roussanne, Y.
    Bonnel, F.
    Canovas, F.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (03): : 330 - 334
  • [7] Reimplantation of a total elbow prosthesis following resection arthroplasty for infection
    Cheung, Emilie V.
    Adams, Robert A.
    Morrey, Bernard F.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (03) : 589 - 594
  • [8] Existence of a rotational axial component in the human humeral medullary canal
    Descamps, S.
    Moreel, P.
    Garcier, J. M.
    Bouillet, B.
    Brehant, J.
    Tanguy, A.
    [J]. SURGICAL AND RADIOLOGIC ANATOMY, 2009, 31 (08) : 579 - 583
  • [9] The flat spot of the proximal ulna: A useful anatomic landmark in total elbow arthroplasty
    Duggal, N
    Dunning, CE
    Johnson, JA
    King, GJW
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2004, 13 (02) : 206 - 207
  • [10] Results after 562 total elbow replacements: A report from the Norwegian Arthroplasty Register
    Fevang, Bjorg-Tilde S.
    Lie, Stein A.
    Havelin, Leif I.
    Skredderstuen, Arne
    Furnes, Ove
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2009, 18 (03) : 449 - 456