A Cumulative Pollution Index for the Estimation of the Leakage Current on Insulator Strings

被引:44
作者
de Santos, Hector [1 ,2 ]
Sanz-Bobi, Miguel Angel [1 ]
机构
[1] Comillas Pontifical Univ, Madrid 28015, Spain
[2] Verescence La Granja Insulators, San Ildefonso 40100, Spain
关键词
Insulators; Leakage currents; Pollution; Glass; Monitoring; Flashover; Pollution measurement; Condition monitoring; contamination; flashover; glass insulators; leakage current; predictive models; random forests; RTV coatings; transmission lines; FLASHOVER MECHANISM; RTV SILICONE;
D O I
10.1109/TPWRD.2020.2968556
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The pollution performance of insulators installed in transmission and distribution lines plays a key role in maintaining the reliability, safety and cost-effectiveness of power systems. Among the different insulator monitoring techniques, leakage current stands out as one of the most meaningful pollution performance indicators as it gives a measure of how close the insulators string is to flashover. This paper presents a novel methodology for the prediction of the leakage current on insulator strings considering the environmental and weather information of the insulators location. It is based on the combination of a new developed Cumulative Pollution Index (CPI), which estimates the soluble pollution deposit on the insulator string, and a machine learning technique such as Random Forests algorithm. The method is valid for ceramic insulators, i.e., toughened glass, as well as RTV silicone-coated insulators with hydrophobic transfer properties. The research is supported by an extensive field monitoring program where three different insulator strings composed by non-coated, half-coated (bottom part) and full-silicone-coated glass insulators were monitored in a period covering twenty-two consecutive months. Finally, the performance of the proposed prediction model is evaluated using real data.
引用
收藏
页码:2438 / 2446
页数:9
相关论文
共 36 条
[11]  
CIGRE, 2008, 361 CIGRE WORK GROUP
[12]  
CIGRE, 1999, 142 CIGRE TASK FORC
[13]  
CIGRE Task Force, 1994, Electra, P79
[14]   HOW TO CHOOSE INSULATORS FOR POLLUTED AREAS [J].
CLAVERIE, P ;
PORCHERO.Y .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1973, PA92 (03) :1121-1131
[15]  
Feilat E. A., 2011, 2011 IEEE GCC Conference and Exhibition (GCC), P593, DOI 10.1109/IEEEGCC.2011.5752602
[16]   On-line leakage current monitoring of 400 kV insulator strings in polluted areas [J].
FierroChavez, JL ;
RamirezVazquez, I ;
MontoyaTena, G .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1996, 143 (06) :560-564
[17]  
GIGRE, 2007, 333 CIGRE WORK GROUP
[18]   AGING IN SILICONE-RUBBER USED FOR OUTDOOR INSULATION [J].
GORUR, RS ;
KARADY, GG ;
JAGOTA, A ;
SHAH, M ;
YATES, AM ;
SCHNEIDER, HM ;
DETOURREIL, C ;
MACKEVICH, JP ;
HOFFMAN, JW ;
ORBECK, T ;
AMBURGEY, G ;
ROKOS, G ;
TOSKEY, GA ;
MUELLER, PR ;
TAY, R ;
WINTER, HJ .
IEEE TRANSACTIONS ON POWER DELIVERY, 1992, 7 (02) :525-538
[19]   EVALUATION OF A NEW PROTECTIVE COATING FOR PORCELAIN INSULATORS [J].
HALL, J ;
ORBECK, T .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (12) :4689-4696
[20]  
Hartschorn S., 2016, MACHINE LEARNING RAN