Implantable defibrillator lead extraction with optimized standard extraction techniques

被引:0
作者
Chu, Xian-Ming [1 ,2 ]
Li, Xue-Bin [1 ]
Zhang, Ping [1 ]
An, Yi [2 ]
Duan, Jiang-Bo [1 ]
Wang, Long [1 ]
Li, Ding [1 ]
Li, Bing [3 ]
Guo, Ji-Hong [1 ]
机构
[1] Peking Univ, Peoples Hosp, Dept Cardiac Electrophysiol, Beijing 100044, Peoples R China
[2] Qingdao Univ, Coll Med, Affiliated Hosp, Dept Cardiol, Qingdao 266100, Peoples R China
[3] Qingdao Univ, Coll Med, Dept Biol, Qingdao 266021, Peoples R China
基金
中国国家自然科学基金;
关键词
Lead; Extraction; Implantable cardioverter-defibrillator; Infection; Complications; ELECTRONIC DEVICE INFECTIONS; PACEMAKER; MANAGEMENT; DIAGNOSIS; MORTALITY; REMOVAL; SYSTEMS;
D O I
10.3724/SP.J.1263.2012.08211
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Implantable cardioverter-defibrillator (ICD) leads might not be extracted especially in developing countries because of the high cost and lack of specialized tools. We aimed to evaluate transvenous extraction of ICD leads using optimized standard techniques. Methods We prospectively analyzed clinical characteristics, optimized extraction techniques and the feasibility of extraction for 40 patients (33 males; mean age 47.9 +/- 16.1 years) with 42 ICD leads. Results Complete procedural success rate was 95.2% (40/42), and the clinical success rate was 97.6% (41/42). One ICD lead required cardiothoracic surgery. Minor complications occurred in three cases (7.5%), and no major complications or death occurred. Locking stylets were used to extract most leads (34, 81.0%) and almost half of the leads (20, 47.6%) required mechanical dilatation to free fibrotic adhesions; these leads had been implanted for a longer period of time than the others (43.7 +/- 18.2 vs. 18.4 +/- 13.4 months, P < 0.05). Three-quarters of the leads (30, 71.4%) were extracted with locking stylets plus manual traction (12, 28.6%), or mechanical dilatation with counter-traction (18, 42.8%) by the superior vena cava approach and one-quarter of the leads (11, 26.2%) were removed by optimized snare techniques using the femoral vein approach. Median extraction time was 20 min (range 2-68 min) per lead. Linear regression analysis showed that the extraction time was significantly correlated with implant duration (r = 0.70, P < 0.001). Median follow-up was 14.5 months (range 1-58 months), no infection, or procedure-related death occurred in our series. Conclusions Our optimized procedure for transvenous extraction of ICD leads provides a practical and low-cost method for standard procedures. J Geriatr Cardiol 2013; 10: 3-9. doi: 10.3724/SP.J.1263.2012.08211
引用
收藏
页码:3 / 9
页数:7
相关论文
共 20 条
  • [11] Initial experience with the Evolution mechanical dilator sheath for lead extraction: Safety and efficacy
    Hussein, Ayman A.
    Wilkoff, Bruce L.
    Martin, David O.
    Karim, Saima
    Kanj, Mohamed
    Callahan, Thomas
    Baranowski, Bryan
    Saliba, Walid I.
    Wazni, Oussama M.
    [J]. HEART RHYTHM, 2010, 7 (07) : 870 - 873
  • [12] Kutarski A, 2010, KARDIOL POL, V68, P736
  • [13] Impact of timing of device removal on mortality in patients with cardiovascular implantable electronic device infections
    Le, Katherine Y.
    Sohail, Muhammad R.
    Friedman, Paul A.
    Uslan, Daniel Z.
    Cha, Stephen S.
    Hayes, David L.
    Wilson, Walter R.
    Steckelberg, James M.
    Baddour, Larry M.
    [J]. HEART RHYTHM, 2011, 8 (11) : 1678 - 1685
  • [14] ICD lead proarrhythmia cured by lead extraction
    Lee, Joseph C.
    Epstein, Laurence M.
    Huffer, Linda L.
    Stevenson, William G.
    Koplan, Bruce A.
    Tedrow, Usha B.
    [J]. HEART RHYTHM, 2009, 6 (05) : 613 - 618
  • [15] Proposed modifications to the Duke criteria for the diagnosis of infective endocarditis
    Li, JS
    Sexton, DJ
    Mick, N
    Nettles, R
    Fowler, VG
    Ryan, T
    Bashore, T
    Corey, GR
    [J]. CLINICAL INFECTIOUS DISEASES, 2000, 30 (04) : 633 - 638
  • [16] Love CJ, 2000, PACE, V23, P544
  • [17] Molina JE, 1997, ANN THORAC SURG, V63, P504
  • [18] Pacemaker and ICD lead extraction with electrosurgical dissection sheaths and standard transvenous extraction systems: results of a randomized trial
    Neuzil, Petr
    Taborsky, Milos
    Rezek, Zdenek
    Vopalka, Roman
    Sediva, Lucie
    Niederle, Petr
    Reddy, Vivek
    [J]. EUROPACE, 2007, 9 (02): : 98 - 104
  • [19] Inappropriate discharges of intravenous implantable cardioverter defibrillators owing to lead failure
    Washizuka, T
    Chinushi, M
    Kazama, R
    Hirono, T
    Watanabe, H
    Komura, S
    Sugiura, H
    Tanabe, Y
    Furushima, H
    Fujita, S
    Okura, Y
    Aizawa, Y
    [J]. INTERNATIONAL HEART JOURNAL, 2005, 46 (05) : 909 - 913
  • [20] Transvenous Lead Extraction: Heart Rhythm Society Expert Consensus on Facilities, Training, Indications, and Patient Management
    Wilkoff, Bruce L.
    Love, Charles J.
    Byrd, Charles L.
    Bongiorni, Maria Grazia
    Carrillo, Roger G.
    Crossley, George H., III
    Epstein, Laurence M.
    Friedman, Richard A.
    Kennergren, Charles E. H.
    Mitkowski, Przemyslaw
    Schaerf, Raymond H. M.
    Wazni, Oussama M.
    [J]. HEART RHYTHM, 2009, 6 (07) : 1085 - 1104