Tapered Fiber-Optic Mach-Zehnder Interferometer for Ultra-High Sensitivity Measurement of Refractive Index

被引:96
|
作者
Ahsani, Vahid [1 ]
Ahmed, Farid [2 ]
Jun, Martin B. G. [1 ,3 ]
Bradley, Colin [1 ]
机构
[1] Univ Victoria, Dept Mech Engn, Victoria, BC V8W 2Y2, Canada
[2] Univ Waterloo, Dept Mech & Mechatron Engn, Waterloo, ON N2L 3G1, Canada
[3] Purdue Univ, Sch Mech Engn, W Lafayette, IN 47907 USA
关键词
Mach-Zehnder interferometer; fiber-optic sensor; refractive index measurement; fiber tapering; SURFACE-PLASMON RESONANCE; CONGESTION DETECTION; SENSOR; TEMPERATURE; FABRICATION; GRATINGS;
D O I
10.3390/s19071652
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A Mach-Zehnder interferometer (MZI) based fiberoptic refractive index (RI) sensor is constructed by uniformly tapering standard single mode fiber (SMF) for RI measurement. A custom flame-based tapering machine is used to fabricate microfiber MZI sensors directly from SMFs. The fabricated MZI device does not require any splicing of fibers and shows excellent RI sensitivity. The sensor with a cladding diameter of 35.5 mu m and length of 20 mm exhibits RI sensitivity of 415 nm/RIU for RI range of 1.332 to 1.384, 1103 nm/RIU for RI range of 1.384 to 1.4204 and 4234 nm/RIU for RI range of 1.4204 to 1.4408, respectively. The sensor reveals a temperature sensitivity of 0.0097 nm/degrees C, which is relatively low in comparison to its ultra-high RI sensitivity. The proposed inexpensive and highly sensitive optical fiber RI sensors have numerous applications in chemical and biochemical sensing fields.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Fabrication and characterization of cascaded tapered Mach-Zehnder interferometer for refractive index sensing
    Bhardwaj, Vanita
    Singh, Vinod Kumar
    SENSORS AND ACTUATORS A-PHYSICAL, 2016, 244 : 30 - 34
  • [32] Study of temperature stability for fiber-optic Mach-Zehnder interferometer filter
    Lu, P
    Liu, DM
    Huang, DX
    Sun, JQ
    2002 3RD INTERNATIONAL CONFERENCE ON MICROWAVE AND MILLIMETER WAVE TECHNOLOGY PROCEEDINGS, 2002, : 1087 - 1089
  • [33] Photonic Crystal Fiber Mach-Zehnder Interferometer for Refractive Index Sensing
    Wang, Jian-Neng
    Tang, Jaw-Luen
    SENSORS, 2012, 12 (03): : 2983 - 2995
  • [34] Enhanced Sensitivity Mach-Zehnder Interferometer-Based Tapered-in-Tapered Fiber-Optic Biosensor for the Immunoassay of C-Reactive Protein
    Xiao, Lei
    Chen, Xinghong
    Li, Xuejin
    Zhang, Jinghan
    Wang, Yan
    Li, Dongqing
    Hong, Xueming
    Shao, Yonghong
    Chen, Yuzhi
    BIOSENSORS-BASEL, 2025, 15 (02):
  • [35] High sensitivity strain sensor based on a novel offset-core single micro-tapered fiber-optic Mach-Zehnder interferometer
    Zhang, Yulan
    Wu, Yongfeng
    Han, Yang
    Wu, Jing
    Ren, Jianxin
    Mao, Yaya
    Mao, Beibei
    Liu, Bo
    Optical Fiber Technology, 2022, 73
  • [36] High sensitivity strain sensor based on a novel offset-core single micro-tapered fiber-optic Mach-Zehnder interferometer
    Zhang, Yulan
    Wu, Yongfeng
    Han, Yang
    Wu, Jing
    Ren, Jianxin
    Mao, Yaya
    Mao, Beibei
    Liu, Bo
    OPTICAL FIBER TECHNOLOGY, 2022, 73
  • [37] Highly Improved Refractive Index Sensitivity in Fiber Mach-Zehnder Interferometer Based on Two Tapers
    Gao, J. W.
    Wang, D. N.
    Xu, Ben
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2023, 35 (17) : 935 - 938
  • [38] The arms arrangement influence on the sensitivity of Mach-Zehnder fiber optic interferometer
    Kepak, Stanislav
    Cubik, Jakub
    Doricak, Jan
    Vasinek, Vladimir
    Siska, Petr
    Liner, Andrej
    Papes, Martin
    OPTICAL SENSORS 2013, 2013, 8774
  • [39] All fiber sensor based on Mach-Zehnder interferometer for simultaneous measurement of temperature and refractive index
    曹晔
    赵晨
    童峥嵘
    OptoelectronicsLetters, 2015, 11 (06) : 438 - 443
  • [40] All fiber sensor based on Mach-Zehnder interferometer for simultaneous measurement of temperature and refractive index
    Cao Y.
    Zhao C.
    Tong Z.-R.
    Optoelectronics Letters, 2015, 11 (06) : 438 - 443