Serial coupling of reversed-phase and hydrophilic interaction liquid chromatography to broaden the elution window for the analysis of pharmaceutical compounds

被引:66
作者
Louw, Stefan [1 ]
Pereira, Alberto S. [1 ]
Lynen, Frederic [1 ]
Hanna-Brown, Melissa [2 ]
Sandra, Pat [1 ]
机构
[1] Univ Ghent, Pfizer Analyt Res Ctr, B-9000 Ghent, Belgium
[2] Pfizer Global R&D, Analyt R&D, Sandwich CT13 9NJ, Kent, England
关键词
Liquid chromatography; Reversed-phase; Hydrophilic interaction; Serial coupling; Pharmaceutical analysis;
D O I
10.1016/j.chroma.2008.08.058
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
It is presently a common practice in drug discovery to analyse samples by reversed-phase liquid chromatography (RPLC) and hydrophilic interaction chromatography (HILIC). To increase throughput, HILIC was connected in series to RPLC by means of a T-piece with make-up flow. The first column is a 2 mm I.D. column having an optimal flow between 0.1 and 0.2 mL/min. Via the T-piece. the flow for the second dimension column with an I.D. of 4.6 mm is adjusted to 1.5-2.0 mL/min with a high acetonitrile content (i.e. >= 80%) mobile phase. Therefore, even in gradient RPLC analysis starting with a mobile phase with high water content, the HILIC column is always operated at high acetonitrile concentration which is required to obtain retention on the HILIC column. The performance of the hyphenated RPLC/HILIC set-up is illustrated with the analysis of two model samples of pharmaceutical interest. Optimization of the conditions in the HILIC dimension is discussed. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:90 / 94
页数:5
相关论文
共 28 条
[1]   HYDROPHILIC-INTERACTION CHROMATOGRAPHY FOR THE SEPARATION OF PEPTIDES, NUCLEIC-ACIDS AND OTHER POLAR COMPOUNDS [J].
ALPERT, AJ .
JOURNAL OF CHROMATOGRAPHY, 1990, 499 :177-196
[2]   validated method for the determination of the ethanol consumption markers ethyl glucuronide, ethyl phosphate, and ethyl sulfate in human urine by reversed-phase/weak anion exchange liquid chromatography-tandem mass spectrometry [J].
Bicker, Wolfgang ;
Laemmerhofer, Michael ;
Keller, Thomas ;
Schuhmacher, Rainer ;
Krska, Rudolf ;
Lindner, Wolfgang .
ANALYTICAL CHEMISTRY, 2006, 78 (16) :5884-5892
[3]   Mixed-mode stationary phases as a complementary selectivity concept in liquid chromatography-tandem mass spectrometry-based bioanalytical assays [J].
Bicker, Wolfgang ;
Laemmerhofer, Michael ;
Lindner, Wolfgang .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (01) :263-266
[4]   Hydrophilic interaction liquid chromatography (HILIC) in proteomics [J].
Boersema, Paul J. ;
Mohammed, Shabaz ;
Heck, Albert J. R. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (01) :151-159
[5]   Hydrophilic interaction chromatography for mass spectrometric metabonomic studies of urine [J].
Cubbon, Simon ;
Bradbury, Timothy ;
Wilson, Julie ;
Thomas-Oates, Jane .
ANALYTICAL CHEMISTRY, 2007, 79 (23) :8911-8918
[6]   A study of retention and overloading of basic compounds with mixed-mode reversed-phase/cation-exchange columns in high performance liquid chromatography [J].
Davies, Nicola H. ;
Euerby, Melvin R. ;
McCalley, David V. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1138 (1-2) :65-72
[7]   Two-dimensional hydrophilic interaction chromatography coupling anion-exchange and hydrophilic interaction columns for separation of 2-pyridylamino derivatives of neutral and sialylated N-glycans [J].
Deguchi, Kisaburo ;
Keira, Takuro ;
Yamada, Kuriko ;
Ito, Hiroki ;
Takegawa, Yasuhiro ;
Nakagawa, Hiroaki ;
Nishimura, Shin-Ichiro .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1189 (1-2) :169-174
[8]   The application of structure-based assessment to support safety and chemistry diligence to manage genotoxic impurities in active pharmaceutical ingredients during drug development [J].
Dobo, KL ;
Greene, N ;
Cyr, MO ;
Caron, S ;
Ku, WW .
REGULATORY TOXICOLOGY AND PHARMACOLOGY, 2006, 44 (03) :282-293
[9]   Orthogonality of separation in two-dimensional liquid chromatography [J].
Gilar, M ;
Olivova, P ;
Daly, AE ;
Gebler, JC .
ANALYTICAL CHEMISTRY, 2005, 77 (19) :6426-6434
[10]   Universal response in liquid chromatography using charged aerosol detection [J].
Gorecki, Tadeusz ;
Lynen, Frederic ;
Szucs, Roman ;
Sandra, Pat .
ANALYTICAL CHEMISTRY, 2006, 78 (09) :3186-3192