Efficacy of a pedicled pericardial fat pad fixed with fibrin glue on postoperative alveolar air leakage

被引:5
作者
Yoshimura, M [1 ]
Tsubota, N [1 ]
Matsuoka, H [1 ]
Sakamoto, T [1 ]
机构
[1] Hyogo Med Ctr Adults, Dept Thorac Surg, Akashi, Hyogo 6738558, Japan
关键词
air leak; pericardial fat pad; fibrin glue; postoperative complication; lung surgery;
D O I
10.1007/s595-002-8108-z
中图分类号
R61 [外科手术学];
学科分类号
摘要
The purpose of this randomized trail was to investigate the effect of using a pedicled pericardial fat pad fixed with fibrin glue on postoperative alveolar air leakage. Thirty consecutive patients with lung cancer, who had moderate alveolar air leaks after pulmonary resection, were randomized into two groups: in group A fibrin glue was applied onto the surface of the leaking raw lung and in group B, after applying fibrin glue in the same manner as in group A, a pedicted pericardial fat pad was immediately fixed to the leaking lung surface with fibrin glue. The duration of the postoperative air leakage and chest tube drainage was recorded. In 6 of 15 patients in group B the air leakage ceased within the first 24 h after pulmonary resection, while in group A only 1 of 15 patients showed a cessation of the air leakage, and a significant difference was noticed between the two groups (P = 0.0309). The duration of the postoperative air leakage was 4.8 +/- 4.6 days in group A and 3.6 +/- 3.4 days in group B. The pedicled pericardial fat pad fixed onto the surface of the leaking raw lung using fibrin glue was found to reduce alveolar air leakage after pulmonary resection.
引用
收藏
页码:26 / 28
页数:3
相关论文
共 9 条
[1]   Prolonged air leak following radical upper lobectomy - An analysis of incidence and possible risk factors [J].
Abolhoda, A ;
Liu, D ;
Brooks, A ;
Burt, M .
CHEST, 1998, 113 (06) :1507-1510
[2]   FIBRIN SEAL - AN ALTERNATIVE TO SUTURE REPAIR IN EXPERIMENTAL PULMONARY SURGERY [J].
BERGSLAND, J ;
KALMBACH, T ;
BALU, D ;
FELDMAN, MJ ;
CARUANA, JA ;
GAGE, AA .
JOURNAL OF SURGICAL RESEARCH, 1986, 40 (04) :340-345
[3]  
BREWER LA, 1953, J THORAC SURG, V26, P507
[4]   EFFECT OF ROUTINE FIBRIN GLUE USE ON THE DURATION OF AIR LEAKS AFTER LOBECTOMY [J].
FLEISHER, AG ;
EVANS, KG ;
NELEMS, B ;
FINLEY, RJ .
ANNALS OF THORACIC SURGERY, 1990, 49 (01) :133-134
[5]   ELECTIVE PULMONARY LOBECTOMY - FACTORS ASSOCIATED WITH MORBIDITY AND OPERATIVE MORTALITY [J].
KEAGY, BA ;
LORES, ME ;
STAREK, PJK ;
MURRAY, GF ;
LUCAS, CL ;
WILCOX, BR .
ANNALS OF THORACIC SURGERY, 1985, 40 (04) :349-352
[6]  
KIRSH MM, 1975, ANN THORAC SURG, V20, P216
[7]  
MACARTHY PM, 1988, ANN THORAC SURG, V45, P203
[8]   THE EFFECT OF FIBRIN GLUING TO SEAL BRONCHIAL AND ALVEOLAR LEAKAGES AFTER PULMONARY RESECTIONS AND DECORTICATIONS [J].
MOURITZEN, C ;
DROMER, M ;
KEINECKE, HO .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1993, 7 (02) :75-80
[9]   Effect of fibrin glue in the reduction of postthoracotomy alveolar air leak [J].
Wong, K ;
Goldstraw, P .
ANNALS OF THORACIC SURGERY, 1997, 64 (04) :979-981