A COTS-Based Portable System to Conduct Accurate Substance Concentration Measurements

被引:10
作者
Aznar-Poveda, Juan [1 ]
Antonio Lopez-Pastor, Jose [1 ]
Garcia-Sanchez, Antonio-Javier [1 ]
Garcia-Haro, Joan [1 ]
Fernandez Otero, Toribio [2 ]
机构
[1] Tech Univ Cartagena, Dept Informat & Commun Technol TIC, ETSIT, Campus Muralla Mar, E-30202 Cartagena, Spain
[2] Tech Univ Cartagena, Ctr Electrochem & Intelligent Mat CEMI, ETSII, Campus Alfonso XIII, E-30203 Cartagena, Spain
关键词
screen-printed electrode; potentiostat; cyclic voltammetry; ASCORBIC-ACID; VITAMIN-C; HPLC; DIAGNOSIS; SAMPLES;
D O I
10.3390/s18020539
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Traditionally, electrochemical procedures aimed at determining substance concentrations have required a costly and cumbersome laboratory environment. Specialized equipment and personnel obtain precise results under complex and time-consuming settings. Innovative electrochemical-based sensors are emerging to alleviate this difficulty. However, they are generally scarce, proprietary hardware and/or software, and focused only on measuring a restricted range of substances. In this paper, we propose a portable, flexible, low-cost system, built from commercial off-the-shelf components and easily controlled, using open-source software. The system is completed with a wireless module, which enables the transmission of measurements to a remote database for their later processing. A well-known PGSTAT100 Autolab device is employed to validate the effectiveness of our proposal. To this end, we select ascorbic acid as the substance under consideration, evaluating the reliability figure and obtaining the calibration curves for both platforms. The final outcomes are shown to be feasible, accurate, and repeatable.
引用
收藏
页数:15
相关论文
共 23 条
[1]   Determination of low-molecular-weight organic acid concentrations in seawater and pore-water samples via HPLC [J].
Albert, DB ;
Martens, CS .
MARINE CHEMISTRY, 1997, 56 (1-2) :27-37
[2]   Detection of postharvest changes of ascorbic acid in fresh-cut melon, kiwi, and pineapple, by using a low cost telemetric system [J].
Barberis, Antonio ;
Fadda, Angela ;
Schirra, Mario ;
Bazzu, GianFranco ;
Serra, Pier Andrea .
FOOD CHEMISTRY, 2012, 135 (03) :1555-1562
[3]  
Conte L.S, 2011, CHROMATOGR SCI SER, V101, P561
[4]   A low-cost miniaturized potentiostat for point-of-care diagnosis [J].
Cruz, Andres Felipe Diaz ;
Norena, Nicolas ;
Kaushik, Ajeet ;
Bhansali, Shekhar .
BIOSENSORS & BIOELECTRONICS, 2014, 62 :249-254
[5]  
DEUTSCH MJ, 1965, J ASSOC OFF AGR CHEM, V48, P1248
[6]   DStat: A Versatile, Open-Source Potentiostat for Electroanalysis and Integration [J].
Dryden, Michael D. M. ;
Wheeler, Aaron R. .
PLOS ONE, 2015, 10 (10)
[7]   Development and validation of an HPLC-DAD method for simultaneous determination of cocaine, benzoic acid, benzoylecgonine and the main adulterants found in products based on cocaine [J].
Floriani, Gisele ;
Gasparetto, Joao Cleverson ;
Pontarolo, Roberto ;
Goncalves, Alan Guilherme .
FORENSIC SCIENCE INTERNATIONAL, 2014, 235 :32-39
[8]  
Harris D.C., 2007, Quantitative Chemical Analysis, V42
[9]   Accuracy of Self Monitoring Blood Glucose Systems in a Clinical Setting: Application of New Planned ISO-Standards [J].
Hasslacher, Christoph ;
Kulozik, Felix ;
Platten, Isabel .
CLINICAL LABORATORY, 2013, 59 (7-8) :727-733
[10]   Voltammetric study of polyviologen and the application of polyviologen-modified glassy carbon electrode in amperometric detection of vitamin C [J].
Hsu, P. -F. ;
Ciou, W. -L. ;
Chen, P. -Y. .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 2008, 38 (09) :1285-1292