Radioactive bone cement for the treatment of spinal metastases: a dosimetric analysis of simulated clinical scenarios

被引:6
作者
Kaneko, T. S. [1 ]
Sehgal, V. [2 ]
Skinner, H. B. [3 ]
Al-Ghazi, M. S. A. L. [2 ]
Ramsinghani, N. S. [2 ]
Marquez Miranda, M. [1 ,4 ]
Keyak, J. H. [5 ,6 ,7 ,8 ]
机构
[1] Univ Calif Irvine, Dept Radiol Sci, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Med Ctr, Dept Radiat Oncol, Orange, CA 92868 USA
[3] St Jude Heritage Med Grp, Fullerton, CA 92835 USA
[4] Technol Univ Mixteca, Postgrad Studies Div, Huajuapan De Leon 69000, Oaxaca, Mexico
[5] Univ Calif Irvine, Chao Family Comprehens Canc Ctr, Irvine, CA 92697 USA
[6] Univ Calif Irvine, Dept Radiol Sci, Irvine, CA 92697 USA
[7] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
[8] Univ Calif Irvine, Dept Mech & Aerosp Engn, Irvine, CA 92697 USA
关键词
PERCUTANEOUS VERTEBROPLASTY; VERTEBRAL METASTASES; MECHANICAL-PROPERTIES; RADIATION; AUGMENTATION; KYPHOPLASTY; THERAPY; RADIOISOTOPES; FRACTURES; ABLATION;
D O I
10.1088/0031-9155/57/13/4387
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Vertebral metastases are a common manifestation of many cancers, potentially leading to vertebral collapse and neurological complications. Conventional treatment often involves percutaneous vertebroplasty/kyphoplasty followed by external beam radiation therapy. As a more convenient alternative, we have introduced radioactive bone cement, i.e. bone cement incorporating a radionuclide. In this study, we used a previously developed Monte Carlo radiation transport modeling method to evaluate dose distributions from phosphorus-32 radioactive cement in simulated clinical scenarios. Isodose curves were generally concentric about the surface of bone cement injected into cadaveric vertebrae, indicating that dose distributions are relatively predictable, thus facilitating treatment planning (cement formulation and dosimetry method are patent pending). Model results indicated that a therapeutic dose could be delivered to tumor/bone within similar to 4 mm of the cement surface while maintaining a safe dose to radiosensitive tissue beyond this distance. This therapeutic range should be sufficient to treat target volumes within the vertebral body when tumor ablation or other techniques are used to create a cavity into which the radioactive cement can be injected. With further development, treating spinal metastases with radioactive bone cement may become a clinically useful and convenient alternative to the conventional two-step approach of percutaneous strength restoration followed by radiotherapy.
引用
收藏
页码:4387 / 4401
页数:15
相关论文
共 42 条
[1]   The effect of pre-vertebroplasty tumor ablation using laser-induced thermotherapy on biomechanical stability and cement fill in the metastatic spine [J].
Ahn, Henry ;
Mousavi, Payam ;
Chin, Lee ;
Roth, Sandra ;
Finkelstein, Joel ;
Vitken, Alex ;
Whyne, Cari .
EUROPEAN SPINE JOURNAL, 2007, 16 (08) :1171-1178
[2]   COMPRESSIVE MECHANICAL-PROPERTIES OF HUMAN CANCELLOUS BONE AFTER GAMMA-IRRADIATION [J].
ANDERSON, MJ ;
KEYAK, JH ;
SKINNER, HB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (05) :747-752
[3]  
[Anonymous], 2006, SEER CANC STAT REV 1
[4]   PHASE I TRIAL OF VERTEBRAL INTRACAVITARY CEMENT AND SAMARIUM (VICS): NOVEL TECHNIQUE FOR TREATMENT OF PAINFUL VERTEBRAL METASTASIS [J].
Ashamalla, Hani ;
Cardoso, Erico ;
Macedon, Mark ;
Guirguis, Adel ;
Weng, Lijun ;
Ali, Shamsah ;
Mokhtar, Bahaa ;
Ashamalla, Michael ;
Panigrahi, Nokul .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03) :836-842
[5]   Percutaneous vertebroplasty for pain relief and spinal stabilization [J].
Barr, JD ;
Barr, MS ;
Lemley, TJ ;
McCann, RM .
SPINE, 2000, 25 (08) :923-928
[6]  
Bass B G, 1999, Cardiovasc Radiat Med, V1, P297, DOI 10.1016/S1522-1865(99)00019-0
[7]  
Bouchet LG, 1999, J NUCL MED, V40, P1947
[8]   Percutaneous tumor curettage and interstitial delivery of samarium-153 coupled with kyphoplasty for treatment of vertebral metastases Technical note [J].
Cardoso, Erico R. ;
Ashamalla, Hani ;
Weng, Lijun ;
Mokhtar, Bahaa ;
Ali, Shamsah ;
Macedon, Mark ;
Guirguis, Adel .
JOURNAL OF NEUROSURGERY-SPINE, 2009, 10 (04) :336-342
[9]   Stereotactic radiosurgery for spinal metastases: Case report and review of treatment options [J].
Chawla, Sheema ;
Abu-Aita, Rami ;
Philip, Abraham ;
Lundquist, Tom ;
Okunieff, Paul ;
Milano, Michael T. .
BONE, 2009, 45 (04) :817-821
[10]   Gamma radiation effects on the glass transition temperature and mechanical properties of PMMA/soot nanocomposites [J].
Clayton, LM ;
Gerasimov, TG ;
Cinke, M ;
Meyyappan, M ;
Harmon, JP .
POLYMER BULLETIN, 2004, 52 (3-4) :259-266