Analysis of the emission pattern from optical diffuser tips is vital to their usage in biomedical applications, especially as they find growing functionality beyond established phototherapy techniques. The use of ultraviolet radiation with diffuser tips increases the need to accurately characterize these devices, both for effective application and to avoid potentially dangerous exposure conditions. This study presents a new method to capture the diffusion pattern at a high resolution through the use of radiochromic film. The film is positioned in a cylinder around the diffuser, light is emitted from the diffuser onto the film and the film expresses a color change relative to the exposure amount. The resulting emission map shows the distribution of power from the diffuser in all direction. This method, which is both quick and inexpensive, generates high-resolution data much simpler than previously published works which required precise goniometric positioning.
引用
收藏
页码:1509 / 1512
页数:4
相关论文
共 20 条
[1]   Gafchromic EBT2 dosimetry via robust optimization [J].
Alves, Victor G. L. ;
Cardoso, Simone C. ;
da Silva, Ademir X. .
COMPUTER PHYSICS COMMUNICATIONS, 2013, 184 (07) :1708-1716
[2]   Germicidal Efficacy and Mammalian Skin Safety of 222-nm UV Light [J].
Buonanno, Manuela ;
Ponnaiya, Brian ;
Welch, David ;
Stanislauskas, Milda ;
Randers-Pehrson, Gerhard ;
Smilenov, Lubomir ;
Lowy, Franklin D. ;
Owens, David M. ;
Brenner, David J. .
RADIATION RESEARCH, 2017, 187 (04) :483-491
[3]   207-nm UV Light-A Promising Tool for Safe Low-Cost Reduction of Surgical Site Infections. II: In-Vivo Safety Studies [J].
Buonanno, Manuela ;
Stanislauskas, Milda ;
Ponnaiya, Brian ;
Bigelow, Alan W. ;
Randers-Pehrson, Gerhard ;
Xu, Yanping ;
Shuryak, Igor ;
Smilenov, Lubomir ;
Owens, David M. ;
Brenner, David J. .
PLOS ONE, 2016, 11 (06)
[4]   207-nm UV Light - A Promising Tool for Safe Low-Cost Reduction of Surgical Site Infections. I: In Vitro Studies [J].
Buonanno, Manuela ;
Randers-Pehrson, Gerhard ;
Bigelow, Alan W. ;
Trivedi, Sheetal ;
Lowy, Franklin D. ;
Spotnitz, Henry M. ;
Hammer, Scott M. ;
Brenner, David J. .
PLOS ONE, 2013, 8 (10)
[5]   Ultraviolet-C Irradiation for Prevention of Central Venous Catheter-related Infections: An In Vitro Study [J].
Dai, Tianhong ;
Tegos, George P. ;
St. Denis, Tyler G. ;
Anderson, Don ;
Sinofsky, Ed ;
Hamblin, Michael R. .
PHOTOCHEMISTRY AND PHOTOBIOLOGY, 2011, 87 (01) :250-255
[6]  
Drobny J. G, 2010, RAD TECHNOLOGY POLYM, P215
[7]  
KEISER G, 2014, BIOMEDO, V19, DOI DOI 10.1117/1.JBO.19.8.080902
[8]   3-DIMENSIONAL CHARACTERIZATION OF THE LIGHT-DISTRIBUTION FROM DIFFUSING CYLINDRICAL OPTICAL-FIBER TIPS [J].
KOZODOY, RL ;
LUNDAHL, SL ;
BELL, D ;
HARRINGTON, JA .
APPLIED OPTICS, 1994, 33 (28) :6674-6682
[9]   Angular dependence of the efficiency of the UV sensor polysulphone film [J].
Krins, A ;
Bolsée, D ;
Dörschel, B ;
Gillotay, D ;
Knuschke, P .
RADIATION PROTECTION DOSIMETRY, 2000, 87 (04) :261-266
[10]   Thin cylindrical diffusers in multimode Ge-doped silica fibers [J].
Lilge, L ;
Vesselov, L ;
Whittington, W .
LASERS IN SURGERY AND MEDICINE, 2005, 36 (03) :245-251