Ultra stable, inkjet-printed pseudo reference electrodes for lab-on-chip integrated electrochemical biosensors

被引:18
作者
Papamatthaiou, Sotirios [1 ,2 ]
Zupancic, Uros [1 ,2 ]
Kalha, Curran [3 ]
Regoutz, Anna [3 ]
Estrela, Pedro [1 ,2 ]
Moschou, Despina [1 ,2 ]
机构
[1] Univ Bath, Ctr Biosensors Bioelect & Biodevices C3Bio, Bath BA2 7AY, Avon, England
[2] Univ Bath, Dept Elect & Elect Engn, Bath BA2 7AY, Avon, England
[3] UCL, Dept Chem, London WC1H 0AJ, England
关键词
TRANSISTORS;
D O I
10.1038/s41598-020-74340-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Lab-on-Chip technology comprises one of the most promising technologies enabling the widespread adoption of Point-of-Care testing in routine clinical practice. However, until now advances in Lab-on-Chip have not been translated to the anticipated degree to commercialized tools, with integrated device mass manufacturing cost still not at a competitive level for several key clinical applications. Lab-on-PCB is currently considered as a candidate technology addressing this issue, owing to its intuitive compatibility with electronics, seamless integration of electrochemical biosensors and the extensive experience regarding industrial manufacturing processes. Inkjet-printing in particular is a compatible fabrication method, widening the range of electronic materials available and thus enabling seamlessly integrated ultrasensitive electronic detection. To this end, in this work stable pseudo-reference electrodes are fabricated for the first time by means of commercial inkjet-printing on a PCB-integrated electrochemical biosensing platform. SEM and XPS analysis are employed to characterize the electrodes' structure and composition and identify any special characteristics, compared to published work on alternative substrates. Additionally, this paper analyzes integrated reference electrodes from a new perspective, focusing mainly on their characteristics in real-life operation: chemical sintering as opposed to high budget thermal one, stability under continuous flow, pH dependency and bias stress effects on electrode instability, a parameter often overlooked in electrochemical biosensors.
引用
收藏
页数:10
相关论文
共 26 条
[1]   Recent progress in lab-on-a-chip for pharmaceutical analysis and pharmacological/toxicological test [J].
Ai, Yongjian ;
Zhang, Feng ;
Wang, Chenlong ;
Xie, Ruoxiao ;
Liang, Qionglin .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2019, 117 :215-230
[2]   A cytokine immunosensor for Multiple Sclerosis detection based upon label-free electrochemical impedance spectroscopy using electroplated printed circuit board electrodes [J].
Bhavsar, Kinjal ;
Fairchild, Aaron ;
Alonas, Eric ;
Bishop, Daniel K. ;
La Belle, Jeffrey T. ;
Sweeney, James ;
Alford, T. L. ;
Joshi, Lokesh .
BIOSENSORS & BIOELECTRONICS, 2009, 25 (02) :506-509
[3]   Commercialization of microfluidic point-of-care diagnostic devices [J].
Chin, Curtis D. ;
Linder, Vincent ;
Sia, Samuel K. .
LAB ON A CHIP, 2012, 12 (12) :2118-2134
[4]   Graphene Solution-Gated Field-Effect Transistor Array for Sensing Applications [J].
Dankerl, Markus ;
Hauf, Moritz V. ;
Lippert, Andreas ;
Hess, Lucas H. ;
Birner, Stefan ;
Sharp, Ian D. ;
Mahmood, Ather ;
Mallet, Pierre ;
Veuillen, Jean-Yves ;
Stutzmann, Martin ;
Garrido, Jose A. .
ADVANCED FUNCTIONAL MATERIALS, 2010, 20 (18) :3117-3124
[5]   Microfluidic Devices for Label-Free DNA Detection [J].
Dutta, Gorachand ;
Rainbow, Joshua ;
Zupancic, Uros ;
Papamatthaiou, Sotirios ;
Estrela, Pedro ;
Moschou, Despina .
CHEMOSENSORS, 2018, 6 (04)
[6]   Simple On-Plastic/Paper Inkjet-Printed Solid-State Ag/AgCI Pseudoreference Electrode [J].
Geroncio da Silva, Everson Thiago Santos ;
Miserere, Sandrine ;
Kubota, Lauro Tatsuo ;
Merkoci, Arben .
ANALYTICAL CHEMISTRY, 2014, 86 (21) :10531-10534
[7]   Conductive Inks with a "Built-In" Mechanism That Enables Sintering at Room Temperature [J].
Grouchko, Michael ;
Kamyshny, Alexander ;
Mihailescu, Cristina Florentina ;
Anghel, Dan Florin ;
Magdassi, Shlomo .
ACS NANO, 2011, 5 (04) :3354-3359
[8]   Carbon nanotube transistors for biosensing applications [J].
Gruner, G .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 384 (02) :322-335
[9]  
Inzelt G., 2013, HDB REFERENCE ELECTR, DOI [10.1007/978-3-642-36188-3, DOI 10.1007/978-3-642-36188-3_14, 10.1007/978-3-642-36188-314]
[10]   Fabrication of high-performance fully depleted silicon-on-insulator based dual-gate ion-sensitive field-effect transistor beyond the Nernstian limit [J].
Jang, Hyun-June ;
Cho, Won-Ju .
APPLIED PHYSICS LETTERS, 2012, 100 (07)