A methodology of design for seismic performance enhancement of buildings using viscous fluid dampers

被引:33
作者
Raju, K. Rama [1 ]
Ansu, M. [1 ]
Iyer, Nagesh R. [1 ]
机构
[1] CSIR Campus, Struct Engn Res Ctr, Madras 600113, Tamil Nadu, India
关键词
buildings; viscous fluid dampers; damper configurations; optimum distribution of dampers; energy dissipation devices; chevron; toggle brace and scissor jack mechanisms; steel moment resistant frame; ENERGY-DISSIPATION; PLACEMENT; OPTIMIZATION;
D O I
10.1002/stc.1568
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A methodology of design for seismic performance enhancement of buildings by using linear viscous fluid dampers (VFDs) is proposed. It also gives the procedure for arriving at an efficient distribution of VFDs in the building. The peak base shear and inter-storey drifts determined from a time history analysis of the building subjected to design basis earthquake (DBE) are used for satisfying the Uniform Building Code 1997 specified target performance criteria for base shear and inter-storey drifts. The methodology proposed is used for designing the linear VFDs to increase the effective damping with chevron, upper toggle, and scissor jack mechanisms in a 20-storey benchmark building subjected to DBE to meet the performance criteria. The time histories of the N-S component of El Centro, N-S component of Kobe, N-S component of Northridge, and S-E component of Taft scaled to a PGA of 0.2g are considered to be representatives of DBE for the place where the 20-storey benchmark building is located. It is observed that the optimum location of the dampers with different mechanisms in the building is the ground floor or the first few storeys from the ground floor. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:342 / 355
页数:14
相关论文
共 32 条
[1]   Integrated Design of Controlled Linear Structural Systems [J].
Cimellaro, G. P. ;
Soong, T. T. ;
Reinhorn, A. M. .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2009, 135 (07) :853-862
[2]   Simultaneous stiffness-damping optimization of structures with respect to acceleration, displacement and base shear [J].
Cimellaro, Gian Paolo .
ENGINEERING STRUCTURES, 2007, 29 (11) :2853-2870
[3]   Optimal softening and damping design for buildings [J].
Cimellaro, Gian Paolo ;
Retamales, Rodrigo .
STRUCTURAL CONTROL & HEALTH MONITORING, 2007, 14 (06) :831-857
[4]   Design of passive systems for control of inelastic structures [J].
Cimellaro, Gian Paolo ;
Lavan, Oren ;
Reinhorn, Andrei M. .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2009, 38 (06) :783-804
[5]  
Constantinou M.C., 1998, PASSIVE ENERGY DISSI
[6]   Toggle-brace-damper seismic energy dissipation systems [J].
Constantinou, MC ;
Tsopelas, P ;
Hammel, W ;
Sigaher, AN .
JOURNAL OF STRUCTURAL ENGINEERING, 2001, 127 (02) :105-112
[7]  
Federal Emergency Management Agency (FEMA), 273274 FEMA BUILD SA
[8]  
FEMA, FEMA 356
[9]   EFFECTS OF ADDED-DAMPER DISTRIBUTION ON THE SEISMIC RESPONSE OF BUILDINGS [J].
HAHN, GD ;
SATHIAVAGEESWARAN, KR .
COMPUTERS & STRUCTURES, 1992, 43 (05) :941-950
[10]  
Hanson RD, 2001, EERI