Validity and Reliability of Short-Term Heart-Rate Variability from the Polar S810

被引:237
作者
Nunan, David [1 ]
Donovan, Gay [1 ]
Jakovljevic, Djordje G. [1 ]
Hodges, Lynette D. [2 ]
Sandercock, Gavin R. H. [3 ]
Brodie, David A. [1 ]
机构
[1] Buckinghamshire New Univ, Res Ctr Soc & Hlth, Chalfont St Giles HP8 4AD, Bucks, England
[2] Univ Bedfordshire, Dept Sport & Exercise Sci, Bedford, England
[3] Univ Essex, Ctr Sports & Exercise Sci, Colchester CO4 3SQ, Essex, England
关键词
CONCURRENT VALIDITY; REPRODUCIBILITY; TECHNICAL ERROR; NOISE; OVERTRAINED; SPECTRAL-ANALYSIS; REPRODUCIBILITY; EXERCISE; AGE; INSTRUMENTS; AGREEMENT;
D O I
10.1249/MSS.0b013e318184a4b1
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
NUNAN, D., G. DONOVAN, D. G. JAKOVLJEVIC, L. D. HODGES, G. R. H. SANDEROCK, and D. A. BRODIE. Validity and Reliability of Short-Term Heart-Rate Variability from the Polar S810. Med. Sci. Sports Exerc., Vol. 41, No. 1, pp. 243-250, 2009. Purpose: To assess the validity and the reliability of short-term resting heart-rate variability (HRV) measures obtained using the Polar S810 heart-rate monitor and accompanying software. Methods: Measures of HRV were obtained from 5-min R to R wave (RR) interval data for 19 males and 14 females during 10 min of quiet rest on three separate occasions at 1-wk intervals using the Polar S810. Criterion measures of HRV were obtained simultaneously using the CardioPerfect (CP; Medical Graphics Corporation, St Paul, MN) 12-lead ECG module. Measures of validity of the Polar S810 were estimated by regression analysis, and measures of reliability of both devices were estimated by analysis of change scores. Measures of the SD of normal-to-normal intervals (SDNN), the root mean square of successive differences (RMSSD), and the low-frequency (LF) and the high-frequency (I-IF) spectral power and their ratio (LF/HF) were analyzed after log transformation, whereas mean RR and LF and HF in normalized units were analyzed without transformation. Results: There were marginal differences between the Polar and the CP mean measures of HRV, and the uncertainty in the differences was small. The Polar S810 demonstrated high correlations (0.85-0.99) with CP for all measures of HRV indicating good to near-perfect validity. Except for the low- and the high-frequency normalized units, Polar S810 did not add ally Substantial technical error to the within-subject variability in the repeated measurements of HRV. Conclusion: HRV measures obtained with the Polar S810 and accompanying software have no appreciable bias or additional random error in comparison with criterion measures, but the measures are inherently unreliable over a 1-wk interval. Reliability of HRV from longer (e.g., 10 min) and/or consecutive 5-min RR recordings needs to be investigated with the Polar and criterion instruments.
引用
收藏
页码:243 / 250
页数:8
相关论文
共 42 条
[1]  
[Anonymous], MEASUREMENT CONCEPTS
[2]  
[Anonymous], 1988, STAT POWER ANAL BEHA
[3]   Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[4]   THE ABILITY OF SEVERAL SHORT-TERM MEASURES OF RR VARIABILITY TO PREDICT MORTALITY AFTER MYOCARDIAL-INFARCTION [J].
BIGGER, JT ;
FLEISS, JL ;
ROLNITZKY, LM ;
STEINMAN, RC .
CIRCULATION, 1993, 88 (03) :927-934
[5]  
Bürklein M, 2005, DEUT Z SPORTMED, V56, P415
[6]  
Camm AJ, 1996, CIRCULATION, V93, P1043
[7]  
Carrasco S., 2003, Journal of Medical Engineering & Technology, V27, P241, DOI 10.1080/0309190031000111380
[8]   Recent advances in heart rate variability signal processing and interpretation [J].
Cerutti, S ;
Goldberger, AL ;
Yamamoto, Y .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (01) :1-3
[9]   Comparison of fast Fourier transform and autoregressive spectral analysis for the study of heart rate variability in diabetic patients [J].
Chemla, D ;
Young, J ;
Badilini, F ;
Malson-Blanche, P ;
Affres, H ;
Lecarpentier, Y ;
Chanson, P .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2005, 104 (03) :307-313
[10]   Ventilatory thresholds assessment from heart rate variability during an incremental exhaustive running test [J].
Cottin, F. ;
Medigue, C. ;
Lopes, P. ;
Lepretre, P.-M. ;
Heubert, R. ;
Billat, V. .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2007, 28 (04) :287-294