Recording scapular motion using an acromion marker cluster

被引:134
作者
van Andel, Carolien [1 ,2 ]
van Hutten, Kim [2 ]
Eversdijk, Marielle [2 ]
Veeger, DirkJan [2 ,3 ]
Harlaar, Jaap [1 ,2 ]
机构
[1] Vrije Univ Amsterdam Med Ctr, Dept Rehabil Med, Res Inst MOVE, NL-1007 MB Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Fac Human Movement Sci, Res Inst MOVE, Amsterdam, Netherlands
[3] Delft Univ Technol, NL-2600 AA Delft, Netherlands
关键词
3D kinematics; Scapula; Acromion; Dynamic; Validation; ELECTROMAGNETIC TRACKING DEVICE; IN-VIVO; SHOULDER IMPINGEMENT; KINEMATICS; MOVEMENT; RELIABILITY; ORIENTATION; VALIDATION; REGRESSION; POSITION;
D O I
10.1016/j.gaitpost.2008.07.012
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Disorders of the shoulder complex can be accompanied by changes in the movement pattern of the scapula. However, scapular motion is difficult to measure. A possible non-invasive method for dynamic three-dimensional kinematic measurement of the human scapula is the use of a marker cluster placed on the flat part of the acromion. A small light-weight acromion market cluster (AMC) is presented in this study. In order to assess validity, kinematics obtained with the AMC were compared to simultaneous scapula locator (SL) recordings in a series Of Postures. The test/retest variability of replacement of the AMC, was also assessed. Measurement errors appeared to be sensitive for the plane of movement, the degree of humerus elevation, and replacement of the AMC. The AMC generally under-estimated scapula motion, compared to the SL. Some significant differences were found between the two methods, although the absolute differences were small (maximum mean difference 8.4 degrees in extreme position). in humerus forward flexion and abduction the maximum mean differences were 6 degrees or lower. in conclusion, the AMC is a valid method of measuring scapular movement during arm elevation that could be used in shoulder pathologies. Placement and planes of movement should be carefully considered and elevation of the humerus should not exceed 100 degrees. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:123 / 128
页数:6
相关论文
共 25 条
  • [1] The measurement of three dimensional scapulohumeral kinematics - a study of reliability
    Barnett, ND
    Duncan, RDD
    Johnson, GR
    [J]. CLINICAL BIOMECHANICS, 1999, 14 (04) : 287 - 290
  • [2] Validation of a new model-based tracking technique for measuring three-dimensional, in vivo glenohumeral joint kinematics
    Bey, Michael J.
    Zauel, Roger
    Brock, Stephanie K.
    Tashman, Scott
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (04): : 604 - 609
  • [3] BRACKBILL E, 2007, P 12 ANN GCMAS M
  • [4] A three-dimensional regression model of the shoulder rhythm
    de Groot, JH
    Brand, R
    [J]. CLINICAL BIOMECHANICS, 2001, 16 (09) : 735 - 743
  • [5] A METHOD FOR THE MEASUREMENT OF 3-DIMENSIONAL SCAPULAR MOVEMENT
    JOHNSON, GR
    STUART, PR
    MITCHELL, S
    [J]. CLINICAL BIOMECHANICS, 1993, 8 (05) : 269 - 273
  • [6] Dynamic measurements of three-dimensional scapular kinematics: A validation study
    Karduna, AR
    McClure, PW
    Michener, LA
    Sennett, B
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (02): : 184 - 190
  • [7] Alterations in shoulder kinematics and associated muscle activity in people with symptoms of shoulder impingement
    Ludewig, PM
    Cook, TM
    [J]. PHYSICAL THERAPY, 2000, 80 (03): : 276 - 291
  • [8] Comparison of 3-dimensional scapular position and orientation between subjects with and without shoulder impingement
    Lukasiewicz, AC
    McClure, P
    Michener, L
    Pratt, N
    Sennett, B
    [J]. JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1999, 29 (10) : 574 - 583
  • [9] Digital fluoroscopic assessment of the scapulohumeral rhythmÉvaluation du rythme scapulohuméral en radioscopie digitalisée
    D. G. Mandalidis
    B. S. Mc Glone
    R. F. Quigley
    D. McInerney
    M. O'Brien
    [J]. Surgical and Radiologic Anatomy, 1999, 21 (Suppl 4) : 241 - 246
  • [10] The unstable shoulder in arm elevation: A three-dimensional and electromyographic study in subjects with glenohumeral instability
    Matias, R
    Pascoal, AG