Analysis of thermal and electrical performance of a hybrid (PV/T) air based solar collector for Iraq

被引:101
作者
Amori, Karima E. [1 ]
Al-Najjar, Hussein M. Taqi [2 ]
机构
[1] Univ Baghdad, Mech Eng Dept, Baghdad, Iraq
[2] Univ Baghdad, Energy Eng Dept, Baghdad, Iraq
关键词
Solar energy; Hybrid collector; PV/T; Thermal; Electrical; Performance; SYSTEM;
D O I
10.1016/j.apenergy.2012.03.061
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The electrical and thermal performance of a typical single pass hybrid photovoltaic/thermal (PV/T) air collector is modeled, simulated and analyzed for two selected case studies in Iraq. An improved mathematical thermo-electrical model is derived in terms of design, operating and climatic parameters of the hybrid solar collector to evaluate its important characteristics: collector flow and heat removal factors, PV maximum power point and its temperature coefficient, and overall power and efficiency. Unlike previous PV/T thermal models, the present model is obtained with some additions and corrections in radiation and convection heat coefficients for the top loss and for the air duct with more applicable sky temperature correlation. The well-known 5-parameter electrical model of PV module is solved using improved boundary conditions and translation equations for better convergence and accuracy. The voltage temperature coefficient of the PV module is included in the boundary conditions for convergence stability. The module parameters are taken to be dependent on solar radiation and PV cell temperature for improved accuracy. A Matlab computer simulation program is developed to solve the thermo-electrical model. The developed model is verified with previously published experimental results and theoretical simulations; it is proved to be most accurate in respect to percentage errors and correlation coefficients. Different parameters of the PV/T collector such as cell and air temperatures, thermal gain. PV current and voltage, and fill factor have been investigated. The results identified the effects of most important operating conditions such as sky, inlet and cell temperatures, air flow rate and incident solar radiation on the performance of the hybrid collector. The approved model is applied for a winter day (22 January 2011) in Baghdad city and for a summer day (20 May 2011) in Fallujah city. It is found that the electrical, thermal and overall collector efficiencies for the two case studies were 12.3%, 19.4% and 53.6% respectively for the winter day, while that for the summer day were 9%, 22.8% and 47.8%. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:384 / 395
页数:12
相关论文
共 23 条
[1]  
Ali Alfegi Ebrahim M., 2009, American Journal of Environmental Sciences, V5, P592, DOI 10.3844/ajessp.2009.592.598
[2]   Statistical thermodynamic foundation for photovoltaic and photothermal conversion III: Application to hybrid solar converters [J].
Badescu, V ;
Landsberg, PT ;
DeVos, A .
JOURNAL OF APPLIED PHYSICS, 1997, 81 (08) :3692-3699
[3]   Thermal modeling of a combined system of photovoltaic thermal (PV/T) solar water heater [J].
Dubey, Swapnil ;
Tiwari, G. N. .
SOLAR ENERGY, 2008, 82 (07) :602-612
[4]   Analytical expression for electrical efficiency of PV/T hybrid air collector [J].
Dubey, Swapnil ;
Sandhu, G. S. ;
Tiwari, G. N. .
APPLIED ENERGY, 2009, 86 (05) :697-705
[5]  
Duffie J.A., 2006, Sol. Eng. Thermal Proces.
[6]   System performance studies on a photovoltaic/thermal (PV/T) air heating collector [J].
Garg, HP ;
Adhikari, RS .
RENEWABLE ENERGY, 1999, 16 (1-4) :725-730
[7]   Conventional hybrid photovoltaic/thermal (PV/T) air heating collectors: Steady-state simulation [J].
Garg, HP ;
Adhikari, RS .
RENEWABLE ENERGY, 1997, 11 (03) :363-385
[8]  
Goh Li Jin, 2010, American Journal of Applied Sciences, V7, P277, DOI 10.3844/ajassp.2010.277.282
[9]   Comparative study of the performances of four photovoltaic/thermal solar air collectors [J].
Hegazy, AA .
ENERGY CONVERSION AND MANAGEMENT, 2000, 41 (08) :861-881
[10]  
Holman J.P., 2008, Heat Transfer