Selenium determination by electrothermal atomic absorption spectrometry in petroleum refinery aqueous streams containing volatile organic compounds

被引:20
作者
Cassella, RJ
de Sant'Ana, OD
Rangel, AT
de Carvalho, MDB
Santelli, R
机构
[1] CEFETEQ RJ, BR-20270021 Rio De Janeiro, Brazil
[2] Univ Fed Fluminense, Dept Geoquim, BR-24020007 Niteroi, RJ, Brazil
[3] Petrobras SA, CENPES, PDEAB QM, Rio De Janeiro, Brazil
关键词
selenium determination; petroleum refinery aqueous streams; electrothermal atomic absorption spectrometry;
D O I
10.1016/S0026-265X(01)00110-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrothermal atomic absorption spectrometry (ETAAS) with polarized Zeeman background correction was used for determining selenium in petroleum refinery aqueous streams containing large amounts of volatile unknown organic compounds. Some parameters that might affect the measurement were investigated such as the amount of matrix modifier added, the temperature program and the calibration mode employed. Obtained results indicate that, in this kind of sample, selenium must be determined by standard addition procedure with a careful control of the dry step temperature and ramp pattern. Also, the results show that 2.5 mug of Pd must be added as matrix modifier to stabilize the analyte in the range of 2-20 ng Se. In order to evaluate the accuracy of the procedure, selenium was determined in 18 samples by ETAAS and hydride generation atomic absorption spectrometry (HGAAS) (as reference methodology). In both techniques the results agreed well. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:21 / 28
页数:8
相关论文
共 19 条
[1]   DETERMINATION OF TRACE AMOUNTS OF SELENIUM AND TELLURIUM IN NICKEL-BASED HEAT-RESISTING SUPERALLOYS, STEELS AND SEVERAL METALS BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY AFTER REDUCTIVE COPRECIPITATION WITH PALLADIUM USING ASCORBIC-ACID [J].
ASHINO, T ;
TAKADA, K .
ANALYTICA CHIMICA ACTA, 1995, 312 (02) :157-163
[2]  
ASTM D1559, 1998, D1559 ASTM, P1
[3]   Selenium and cadmium induced pulmonary functional impairment and cytotoxicity [J].
Bell, RR ;
Soliman, MMRI ;
Nonavinakere, VK ;
Hammerbeck, DM ;
Early, JL .
TOXICOLOGY LETTERS, 1997, 90 (2-3) :107-114
[4]  
Bronzetti Georgio, 1993, Journal of Environmental Pathology Toxicology and Oncology, V12, P59
[5]   Direct determination of selenium in serum by electrothermal atomic absorption spectrometry using automated ultrasonic slurry sampling [J].
Chen, WK ;
Yen, CC ;
Wei, BL ;
Hu, CC ;
Yu, JJ ;
Chung, C ;
Kuo, SC .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (01) :131-138
[6]  
D'Ulivo A, 1997, ANALYST, V122, p117R, DOI 10.1039/a704759b
[7]  
GERHARDT MB, 1992, REMOVAL SELENIUM PET, P2
[8]   DETERMINATION OF SELENIUM IN HUMAN HAIR AND NAIL BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
HARRISON, I ;
LITTLEJOHN, D ;
FELL, GS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (03) :215-219
[9]   SUBCHRONIC HEPATOTOXICITY OF SELENOMETHIONINE INGESTION IN MALLARD DUCKS [J].
HOFFMAN, DJ ;
HEINZ, GH ;
LECAPTAIN, LJ ;
BUNCK, CM ;
GREEN, DE .
JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH, 1991, 32 (04) :449-464
[10]  
Jaganathan J, 1998, AM J ENOL VITICULT, V49, P115