Characterization of a SPECT pinhole collimator for optimal detector usage (the lofthole)

被引:23
作者
Deprez, Karel [1 ]
Pato, Lara R. V. [1 ]
Vandenberghe, Stefaan [1 ]
Van Holen, Roel [1 ]
机构
[1] Univ Ghent, IMinds IBiTech, Dept Elect & Informat Syst, MEDISIP, B-9000 Ghent, Belgium
关键词
SMALL-ANIMAL SPECT; ANALYTIC DETERMINATION; GAMMA-CAMERA; RESOLUTION; DESIGN; SYSTEM; RECONSTRUCTION; SENSITIVITY; RAY; FASTSPECT;
D O I
10.1088/0031-9155/58/4/859
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In single-photon emission computed tomography (SPECT), multi-pinhole collimation is often employed nowadays. Most multi-pinhole collimators avoid overlap (multiplexing) of the projections on the detector. This can be done by using additional shielding or by spacing the pinholes far enough apart. Using additional shielding has the drawback that it increases weight, design complexity and cost. Spacing the pinholes far enough apart results in suboptimal detector usage, the valuable detector area is not entirely used. This is due to the circular projections of pinholes on the detector; these ellipses can not be tiled with high detector coverage. To overcome this we designed a new pinhole geometry, the lofthole, that has a rectangular projection on the detector. The lofthole has a circular aperture and a rectangular entrance/exit opening. Sensitivity formulae have been derived for pinholes and loftholes. These formulae take the penumbra effect into account; the proposed formulae do not take penetration into account. The derived formulae are valid for geometries where the field-of-view and the sensitivity of the aperture are solely limited by the exit window. A flood map measurement was performed to compare the rectangular projection of a lofthole with the circular projection of a pinhole. Finally, measurements were done to compare the amount of penetration of pinholes with the amount of penetration of a lofthole. A square lofthole collimator has less penetration than a knife-edge pinhole collimator that irradiates the same rectangular detector area with full coverage. A multi-lofthole collimator allows high detector coverage without using additional shielding. An additional advantage is the lower amount of penetration.
引用
收藏
页码:859 / 885
页数:27
相关论文
共 37 条
[1]   Analytic determination of the resolution-equivalent effective diameter of a pinhole collimator [J].
Accorsi, R ;
Metzler, SD .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (06) :750-763
[2]  
Anger H.O., 1967, INSTRUMENTATION NUCL, V1, P485
[3]  
Anger H.O., 1959, Proceedings of a Symposium held by I.A.E.A. and W.H.O. in Vienna, P59
[4]  
Barett H H, 1996, RADIOLOGICAL IMAGING
[5]   A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential [J].
Bocher, Moshe ;
Blevis, Ira M. ;
Tsukerman, Leonid ;
Shrem, Yigal ;
Kovalski, Gil ;
Volokh, Lana .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (10) :1887-1902
[6]   Rapid additive manufacturing of MR compatible multipinhole collimators with selective laser melting of tungsten powder [J].
Deprez, Karel ;
Vandenberghe, Stefaan ;
Van Audenhaege, Karen ;
Van Vaerenbergh, Jonas ;
Van Holen, Roel .
MEDICAL PHYSICS, 2013, 40 (01)
[7]  
Deprez K, 2010, IEEE NUCL SCI CONF R, P3100, DOI 10.1109/NSSMIC.2010.5874371
[8]   A multipinhole small animal SPECT system with submillimeter spatial resolution [J].
Funk, Tobias ;
Despres, Philippe ;
Barber, William C. ;
Shah, Kanai S. ;
Hasegawa, Bruce H. .
MEDICAL PHYSICS, 2006, 33 (05) :1259-1268
[9]   FastSPECT II: A second-generation high-resolution dynamic SPECT imager [J].
Furenlid, LR ;
Wilson, DW ;
Chen, YC ;
Kim, H ;
Pietraski, PJ ;
Crawford, MJ ;
Barrett, HH .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (03) :631-635
[10]   Theoretical analysis of full-ring multi-pinhole brain SPECT [J].
Goorden, M. C. ;
Rentmeester, M. C. M. ;
Beekman, F. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (21) :6593-6610