Management of radiation oncology patients with a pacemaker or ICD: A new comprehensive practical guideline in The Netherlands

被引:143
作者
Hurkmans, Coen W. [1 ,8 ]
Knegjens, Joost L. [2 ,8 ]
Oei, Bing S. [3 ,8 ]
Maas, Ad J. J. [4 ,9 ]
Uiterwaal, G. J. [5 ,9 ]
van der Borden, Arnoud J. [6 ,10 ]
Ploegmakers, Marleen M. J. [11 ]
van Erven, Lieselot [7 ,12 ]
机构
[1] Catharina Hosp, Dept Radiat Oncol, Eindhoven, Netherlands
[2] Antoni Van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Radiat Oncol, Amsterdam, Netherlands
[3] Verbeeten Inst, Dept Radiat Oncol, Tilburg, Netherlands
[4] Jeroen Bosch Ziekenhuis, Dept Clin Phys, sHertogenbosch, Netherlands
[5] Flevoziekenhuis, Dept Cardiol, Almere, Netherlands
[6] Univ Groningen, Univ Med Ctr Groningen, Dept Radiat Oncol, NL-9713 AV Groningen, Netherlands
[7] Leiden Univ, Med Ctr, Dept Cardiol, Leiden, Netherlands
[8] Dutch Soc Radiotherapy & Oncol NVRO, Utrecht, Netherlands
[9] Dutch Soc Specialists Invas Heart Stimulat VITHaS, Utrecht, Netherlands
[10] Dutch Soc Clin Phys NVKF, Utrecht, Netherlands
[11] OMS, Utrecht, Netherlands
[12] Dutch Soc Cardiol NVCC, Utrecht, Netherlands
关键词
Pacemaker; Implantable cardioverter defibrillator; Guideline; CIED; Risk management; IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS; CARDIAC-PACEMAKERS; LATEST GENERATION; ELECTROMAGNETIC-INTERFERENCE; POSTTRAUMATIC STRESS; RADIOTHERAPY; IRRADIATION; THERAPY; REPLACEMENT; DEVICES;
D O I
10.1186/1748-717X-7-198
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Current clinical guidelines for the management of radiotherapy patients having either a pacemaker or implantable cardioverter defibrillator (both CIEDs: Cardiac Implantable Electronic Devices) do not cover modern radiotherapy techniques and do not take the patient's perspective into account. Available data on the frequency and cause of CIED failure during radiation therapy are limited and do not converge. The Dutch Society of Radiotherapy and Oncology (NVRO) initiated a multidisciplinary task group consisting of clinical physicists, cardiologists, radiation oncologists, pacemaker and ICD technologists to develop evidence based consensus guidelines for the management of CIED patients. CIED patients receiving radiotherapy should be categorised based on the chance of device failure and the clinical consequences in case of failure. Although there is no clear cut-off point nor a clear linear relationship, in general, chances of device failure increase with increasing doses. Clinical consequences of device failures like loss of pacing, carry the most risks in pacing dependent patients. Cumulative dose and pacing dependency have been combined to categorise patients into low, medium and high risk groups. Patients receiving a dose of less than 2 Gy to their CIED are categorised as low risk, unless pacing dependent since then they are medium risk. Between 2 and 10 Gy, all patients are categorised as medium risk, while above 10 Gy every patient is categorised as high risk. Measures to secure patient safety are described for each category. This guideline for the management of CIED patients receiving radiotherapy takes into account modern radiotherapy techniques, CIED technology, the patients' perspective and the practical aspects necessary for the safe management of these patients. The guideline is implemented in The Netherlands in 2012 and is expected to find clinical acceptance outside The Netherlands as well.
引用
收藏
页数:10
相关论文
共 54 条
[1]   Recurrent Implantable Cardioverter-Defibrillator Replacement Is Associated with an Increasing Risk of Pocket-Related Complications [J].
Borleffs, C. Jan Willem ;
Thijssen, Joep ;
de Bie, Mihaly K. ;
van Rees, Johannes B. ;
van Welsenes, Guido H. ;
van Erven, Lieselot ;
Bax, Jeroen J. ;
Cannegieter, Suzanne C. ;
Schalij, Martin J. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2010, 33 (08) :1013-1019
[2]  
Boston Scientific, 2008, THER RAD IMPL PAC DE
[3]   An Updated Review of Implantable Cardioverter/Defibrillators, Induced Anxiety, and Quality of Life [J].
Bostwick, J. Michael ;
Sola, Christopher L. .
HEART FAILURE CLINICS, 2011, 7 (01) :101-+
[4]   Avoiding Mastectomy: Accelerated Partial Breast Irradiation for Breast Cancer Patients with Pacemakers or Defibrillators [J].
Croshaw, Randal ;
Kim, Yongbok ;
Lappinen, Erik ;
Julian, Thomas ;
Trombetta, Mark .
ANNALS OF SURGICAL ONCOLOGY, 2011, 18 (12) :3500-3505
[5]  
Crossley GH, 2011, HEART RHYTHM, V8, P1114, DOI 10.1016/j.hrthm.2010.12.023
[6]   Cardiac device infections are associated with a significant mortality risk [J].
de Bie, Mihaly K. ;
van Rees, Johannes B. ;
Thijssen, J. ;
Borleffs, C. Jan Willem ;
Trines, Serge A. ;
Cannegieter, Suzanne C. ;
Schalij, Martin J. ;
van Erven, Lieselot .
HEART RHYTHM, 2012, 9 (04) :494-498
[7]  
Diederich S, 2000, CANCER, V89, P2457, DOI 10.1002/1097-0142(20001201)89:11+<2457::AID-CNCR22>3.0.CO
[8]  
2-7
[9]   Irradiation of pacemakers and cardio-defibrillators in patients submitted to radiotherapy: a clinical experience [J].
Ferrara, Teresa ;
Baiotto, Barbara ;
Malinverni, Giuseppe ;
Caria, Nicola ;
Garibaldi, Elisabetta ;
Barboni, Gilberto ;
Stasi, Michele ;
Gabriele, Pietro .
TUMORI, 2010, 96 (01) :76-83
[10]  
Franco L, 2005, SEUS COMMERCIAL SRAM