Pyroelectric Composite Film for X-ray Intensity Detection

被引:3
|
作者
Sakamoto, Walter Katsumi [1 ]
Estevam, Giuliano Pierre [2 ]
de Carvalho, Aparecido Augusto [3 ]
Pontes, Wesley [2 ]
de Paula, Mauro Henrique [4 ]
机构
[1] Univ Estadual Paulista UNESP, Grp Polimeros, Dept Quim & Fis, Fac Engn, BR-15385000 Ilha Solteira, Sp, Brazil
[2] Fac Tecnol FATEC Aracatuba, BR-16052045 Aracatuba, SP, Brazil
[3] Univ Estadual Paulista UNESP, Dept Engn Eletr, Fac Engn, BR-15385000 Ilha Solteira, SP, Brazil
[4] Univ Fed Mato Grosso Sul UFMS, Dept Fis, BR-79070900 Campo Grande, MS, Brazil
来源
MATERIALS RESEARCH-IBERO-AMERICAN JOURNAL OF MATERIALS | 2012年 / 15卷 / 02期
基金
巴西圣保罗研究基金会;
关键词
composite; pyroelectricity; X-ray radiation sensor; RADIATION;
D O I
10.1590/S1516-14392012005000030
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Composite material obtained with modified lead titanate (Pz34) ferroelectric ceramic and polyether-ether-ketone (PEEK) polymer matrix was used as sensitive component to measure X-ray intensity in a novel detection system. The sensing element works as a thermal transducer, converting a non-quantified thermal flux into an output measurable quantity of electrical voltage. The samples were obtained up to 60 vol.% of ceramic, by hot pressing the mixture of Pz34 and PEEK powders at 368 degrees C and applying 12 MPa pressure for 2.0 hours. The sensor response varies from 2.70 to 0.80 V in the energy fluence rate range of 6.30 to 37.20 W.m(-2). The absorbed incident energy was analyzed as a function of the ionizing energy. Furthermore, by measuring the pyroelectric activity of the composite film it was observed that there is no degradation of the sensor after the irradiation.
引用
收藏
页码:198 / 203
页数:6
相关论文
共 50 条
  • [1] PYROELECTRIC DETECTION OF X-RAY ABSORPTION BY TOURMALINE
    BOSE, DN
    HENISCH, HK
    TOOLE, JM
    SOLID-STATE ELECTRONICS, 1969, 12 (02) : 65 - &
  • [2] PYROELECTRIC X-RAY GENERATOR
    BROWNRIDGE, JD
    NATURE, 1992, 358 (6384) : 287 - 288
  • [3] X-ray fluorescence analysis with a pyroelectric x-ray generator
    Kawai, J
    Ida, H
    Murakami, H
    Koyama, T
    X-RAY SPECTROMETRY, 2005, 34 (06) : 521 - 524
  • [4] Portable x-ray fluorescence spectrometer with a pyroelectric x-ray generator
    Ida, H
    Kawai, J
    X-RAY SPECTROMETRY, 2005, 34 (03) : 225 - 229
  • [5] Pyroelectric X-ray application to X-ray absorption and emission spectroscopies
    Kawai, Jun
    Ishii, Hideshi
    Ida, Hiroyuki
    X-RAY SPECTROMETRY, 2012, 41 (04) : 216 - 218
  • [6] PYROELECTRIC X-RAY-DETECTORS AND X-RAY PYROMETERS
    WANG, CL
    AUERBACH, JM
    ECKELS, JD
    KOO, JC
    KORNBLUM, HN
    PRICE, DF
    SMITH, JA
    STOTLAR, SC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1986, 57 (08): : 2177 - 2178
  • [7] Optimization of Pyroelectric X-Ray Sources
    Klopfer, M.
    Wolowiec, T.
    Alivov, Y.
    Satchouk, V.
    Molloi, S.
    MEDICAL PHYSICS, 2012, 39 (06) : 3896 - 3896
  • [8] Identification of steel by X-ray fluorescence analysis with a pyroelectric X-ray generator
    Ida, H
    Kawai, J
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (04) : 735 - 738
  • [9] Spatially resolved X-ray fluorescence analysis with a pyroelectric X-ray emitter
    Hatakeyama, So
    Kunimura, Shinsuke
    Sasaki, Nobuharu
    Yamamoto, Takashi
    Kawai, Jun
    ANALYTICAL SCIENCES, 2008, 24 (07) : 847 - 850
  • [10] Improved pyroelectric X-ray generator for planetary active X-ray spectroscopy
    Naito, Masayuki
    Hasebe, Nobuyuki
    Nagaoka, Hiroshi
    Oshima, Yusuke
    Mizone, Miho
    Shibamura, Eido
    Kuno, Haruyoshi
    Kim, Kyeong J.
    Matias-Lopes, Jose A.
    Martinez-Frias, Jesus
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XIX, 2017, 10392