Standard Clinical Outcomes With a New Low Addition Trifocal Intraocular Lens

被引:14
|
作者
Fernandez, Joaquin [1 ,2 ]
Rodriguez-Vallejo, Manuel [1 ]
Martinez, Javier [1 ]
Tauste, Ana [1 ]
Pinero, David P. [3 ,4 ]
机构
[1] Vithas Virgen del Mar Hosp, Dept Ophthalmol Qvis, Almeria, Spain
[2] Torrecardenas Hosp Complex, Dept Ophthalmol, Almeria, Spain
[3] Univ Alicante, Dept Opt Pharmacol & Anat, Alicante, Spain
[4] Vithas Medimar Int Hosp, Dept Ophthalmol, Alicante, Spain
关键词
VISUAL OUTCOMES; EXTENDED DEPTH; IMPLANTATION; PERFORMANCE; ACCURACY; SURGERY; QUALITY; VF-14;
D O I
10.3928/1081597X-20190306-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the standard clinical outcomes, defocus curves, and satisfaction obtained with a new diffractive low addition trifocal intraocular lens (IOL). METHODS: Thirty patients who were implanted with the Versario Multifocal 3F IOL (Valeant Med Sp.zo.o., Warsaw, Poland) were recruited for a prospective observational study at Qvision, Vithas Virgen del Mar Hospital, Almeria, Spain. Variables for reporting standard outcomes were collected at the 1-month visit for monocular vision and the 3-month visit for binocular vision, including best spectacle refraction and corrected and uncorrected visual acuities at far, intermediate (67 cm), and near (40 cm) distances. In addition, monocular and binocular visual acuity defocus curves were measured and questionnaires for grading subjective visual quality, satisfaction, and visual function were supplied at the end of the follow-up. RESULTS: Monocular corrected distance visual acuity decreased progressively from far (-0.05 logMAR) to near (0.25 logMAR) and improved approximately -0.1 logMAR along the defocus curve in binocular vision. The mean residual spherical equivalent (SE) was 0.15 +/- 0.47 diopters (D), with 79% of eyes within +/- 0.50 D and 97% within +/- 1.00 D with the SRK/T formula. All of the visual function tasks improved after surgery, especially driving at night, which increased from 58 to 79 (P < .05). Of 27 patients, 84.4% were satisfied or very satisfied with their general vision. CONCLUSIONS: This new lens was similar in terms of visual performance and satisfaction to other trifocal IOLs. It can be classified as a trifocal extended depth of focus IOL because of the performance between extended depth of focus IOLs and medium-high addition trifocal IOLs.
引用
收藏
页码:214 / +
页数:9
相关论文
共 50 条
  • [21] Clinical outcomes of trifocal toric intraocular lenses
    Tana-Rivero, Pedro
    Rodriguez-Carrillo Maria, Dolores
    Tana-Sanz, Pedro
    Ruiz-Santos, Maria
    Tana-Sanz, Santiago
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (05) : 1773 - 1785
  • [22] Clinical outcomes of new toric trifocal diffractive intraocular lens in patients with cataract and stable keratoconus Six months follow-up
    Farideh, Doroodgar
    Azad, Sanginabadi
    Feizollah, Niazi
    Sana, Niazi
    Cyrus, Alinia
    Mohammad, Ghoreishi
    Alireza, Baradaran-rafii
    MEDICINE, 2017, 96 (12)
  • [23] Clinical outcome of a quadrifocal (trifocal) intraocular lens in Chinese patients: prospective, observational case series
    Chang, John S. M.
    Liu, Sylvia C. T.
    Ma, Nadine T. C.
    Ng, Jack C. M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (03) : 246 - 252
  • [24] AcrySof IQ PanOptix Intraocular Lens Versus Extended Depth of Focus Intraocular Lens and Trifocal Intraocular Lens: A Clinical Overview
    Sudhir, Rachapalle Reddi
    Dey, Arindam
    Bhattacharrya, Shovan
    Bahulayan, Amit
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2019, 8 (04): : 335 - 349
  • [25] Laboratory and Clinical Experience With a Diffractive Trifocal Intraocular Lens Sutured to an Artificial Iris
    Mayer, Christian S.
    Son, Hyeck-Soo
    Labuz, Grzegorz
    Baur, Isabella D.
    Yildirim, Timur M.
    Auffarth, Gerd U.
    Khoramnia, Ramin
    JOURNAL OF REFRACTIVE SURGERY, 2022, 38 (01) : 61 - +
  • [26] Clinical outcomes of a diffractive trifocal intraocular lens with femtosecond laser, digital tracking, and intraoperative aberrometry
    Blaylock, John F.
    Hall, Brad
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2022, 57 (05): : 291 - 296
  • [27] Visual outcomes and subjective experience after bilateral implantation of a new diffractive trifocal intraocular lens
    Sheppard, Amy L.
    Shah, Sunil
    Bhatt, Uday
    Bhogal, Gurpreet
    Wolffsohn, James S.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (03) : 343 - 349
  • [28] Comparison of clinical outcomes of trifocal intraocular lens (AT LISA, Eyecryl SERT trifocal) versus extended depth of focus intraocular lens (Eyhance, Eyecryl SERT EDOF)
    Karuppiah, Preethi
    Varman, N. V. Arulmozhi
    Varman, Aadithreya
    Balakumar, Dinesh
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (08) : 2867 - 2871
  • [29] A comparative study of the visual outcomes between a new trifocal and an extended depth of focus intraocular lens
    Ruiz-Mesa, Ramon
    Abengozar-Vela, Antonio
    Ruiz-Santos, Maria
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2018, 28 (02) : 182 - 187
  • [30] Clinical Comparison of a Trifocal and a Trifocal-Toric Intraocular Lens Based on the Same Diffractive Platform
    Gerl, M.
    Breyer, D. R. H.
    Hagen, P.
    Koss, M. J.
    Mueller, M.
    Al Saad, M.
    Gerl, R. H.
    Kaymak, H.
    Klabe, K.
    Kretz, F. T. A.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2017, 234 (10) : 1276 - 1282