Validated RP-TLC Method with Densitometry for Assay of Finasteride in Simple Pharmaceutical Dosage Form

被引:3
作者
Dolowy, Malgorzata [1 ]
Piontek, Agata [2 ]
Pyka-Pajak, Alina [1 ]
机构
[1] Med Univ Silesia, Sch Pharm, Div Lab Med Sosnowiec, Dept Analyt Chem, 4 Jagielloriska St, PL-41200 Katowice, Poland
[2] Med Univ Silesia, Div Lab Med Sosnowiec, Sch Pharm, Student Res Grp,Dept Analyt Chem, Katowice, Poland
关键词
Finasteride; steroids; chromatography; RP-TLC; densitometry; validation; HUMAN PLASMA; LIQUID-CHROMATOGRAPHY; PROSTATE-CANCER; UPLC METHOD; PREVENTION; TABLETS; MS/MS;
D O I
10.2174/1573412913666170608100215
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: Finasteride is a medically important compound belonging to 4-azasteroids which are widely used in the treatment of benign prostatic hypertrophy. Therefore, there is a need to find a simple, cost effective and sensitive method for the determination of finasteride in commercially available tablet dosage form. Objective: To develop and validate a rapid and simple RP-TLC method combined with densitometry for the quantification of finasteride in tablet dosage form containing 5 mg of active substance alone. Method: Chromatographic analysis was performed on aluminum plates precoated with silica gel 60 RP18F(254) using mobile phase consisting of 1,4-dioxane-water in volume composition 35: 15. Densitometric scanning was done in the absorbance mode at 212 nm. Validation of proposed RP-TLC method was carried out according to the ICH guidelines. Results: Validation data indicated that the proposed RP-TLC method was accurate and precise with coefficient of variation CV, to be less than 2% in both cases. The method was linear over the range of 1.00 divided by 4.00 mu g/spot with correlation coefficient equal to 0.9981. The LOD and LOQ were found to be 0.24 and 0.74 mu g/spot, respectively. Assay results of finasteride in marketed tablets using this method were in agreement with label claim and also with pharmacopoeial requirements. Conclusion: A new, simple and economical RP-TLC method with densitometry developed in this study can be found to be suitable for routine analysis of finasteride in simple tablet dosage form containing this active substance.
引用
收藏
页码:298 / 305
页数:8
相关论文
共 27 条
[1]  
Ahmed S. M, 2015, J ANAL BIOANAL TECH, V6, P247
[2]  
Amin Alaa S, 2012, Pharm Methods, V3, P48, DOI 10.4103/2229-4708.97726
[3]  
[Anonymous], 2014, POL PHARM SOC
[4]  
[Anonymous], 2005, ICH Harmonised Tripartite Guideline: Validation of Analytical Procedures: Text and Methodology
[5]  
Belal TS., 2014, ANAL CHEM RES, V1, P23, DOI [DOI 10.1016/J.ANCR.2014.06.004, 10.1016/j.ancr.2014.06.004]
[6]   Development and validation of an LC-MS assay for finasteride and its application to prostate cancer prevention trial sample analysis [J].
Chen, Xiaohong ;
Gardner, Erin R. ;
Price, Douglas K. ;
Figg, William D. .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2008, 46 (04) :356-361
[7]   Determination of finasteride in the tablet form by liquid chromatography and its analytical method validation [J].
Demir, H ;
Cucu, A ;
Sakarya, S .
ANALYTICA CHIMICA ACTA, 2006, 557 (1-2) :252-255
[8]   Validated UPLC method for the fast and sensitive determination of steroid residues in support of cleaning validation in formulation area [J].
Fekete, Szabolcs ;
Fekete, Jeno ;
Ganzler, Katalin .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 49 (03) :833-838
[9]   A rapid, simple, specific liquid chromatographic-electrospray mass spectrometry method for the determination of finasteride in human plasma and its application to pharmacokinetic study [J].
Guo, Fanc-Qiu ;
Huang, Lan-Fang ;
Wong, Kin Ping ;
Dai, Yun-Hui ;
Li, Ya-Wen ;
Liang, Yi-Zeng ;
Huang, Ke-Long ;
Zhong, Ke-Jun ;
Wu, Ming-Han .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (04) :1507-1513
[10]  
Khan Masood A, 2004, Rev Urol, V6, P97