The role of ICP-MS in inorganic chemical metrology

被引:23
|
作者
Sargent, M. [1 ]
Goenaga-Infante, H. [2 ]
Inagaki, K. [3 ]
Ma, L. [4 ]
Meija, J. [5 ]
Pramann, A. [6 ]
Rienitz, O. [6 ]
Sturgeon, R. [5 ]
Vogl, J. [7 ]
Wang, J. [4 ]
Yang, L. [5 ]
机构
[1] Sudell House Upper Brighton Rd, Surbiton KT6 6LB, England
[2] LGC Ltd, Queens Rd, Teddington TW11 0LY, Middx, England
[3] Natl Metrol Inst Japan, 1-1-1 Umezono, Tsukuba, Ibaraki 3058563, Japan
[4] Natl Inst Metrol, 18 Bei San Huan Dong Lu, Beijing 100029, Peoples R China
[5] Natl Res Council Canada, 1200 Montreal Rd, Ottawa, ON K1A 0R6, Canada
[6] PTB, Bundesallee 100, D-38116 Braunschweig, Germany
[7] Bundesanstalt Mat Forsch & Prufung BAM, Richard Willstatter Str 11, D-12489 Berlin, Germany
关键词
CCQM; metrology; interlaboratory comparison; ICP-MS; mass spectrometry; hyphenated; isotope ratio; INDUCTIVELY-COUPLED PLASMA; DILUTION MASS-SPECTROMETRY; STANDARD ADDITION EXPERIMENTS; AMOUNT RATIO MEASUREMENTS; LASER-ABLATION; ISOTOPE-RATIO; TRACE-METALS; ION-SOURCE; MEASUREMENT UNCERTAINTY; ANALYTICAL-CHEMISTRY;
D O I
10.1088/1681-7575/ab0eac
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
ICP-MS has played a key role in inorganic chemical metrology for 25 years, from the 1993 CIPM feasibility study which led to establishment of the CCQM. Since that time, the Inorganic Analysis Working Group of the CCQM has organised 56 international comparisons involving measurements by ICP-MS and, in a recent comparison, 16 different national institutes submitted their results using the technique. Metrological applications of ICP-MS currently address an enormous range of measurements using a wide variety of instrumentation, calibration strategies and methodologies. This review provides an overview of the ICP-MS field with an emphasis on developments which are of particular relevance to chemical metrology. Examples from CCQM comparisons and the services available from the participants are used to illustrate how the capability and scope of ICP-MS methods have expanded far beyond the expectations of 1993. This is due in part to the research and development programmes of the national institutes which participate in the CCQM. They have played a key role in advancing new instrumentation and applications for elemental analysis, isotope dilution mass spectrometry, determination of isotopic ratio or composition, and speciation of organometallic compounds. These developments are continuing today, as demonstrated by work in new fields such as heteroatom quantitation of proteins, characterisation and counting of nanoparticles using spICP-MS, and LA-ICP-MS analysis of solid materials.
引用
收藏
页数:31
相关论文
共 50 条
  • [21] Evaluation of semiquantitative analysis mode in ICP-MS
    Chen, Heidi
    Dabek-Zlotorzynska, Ewa
    Rasmussen, Pat E.
    Hassan, Nouri
    Lanouette, Monique
    TALANTA, 2008, 74 (05) : 1547 - 1555
  • [22] Analysis of Wastewater by ICP-MS
    P. V. Yakimovich
    A. V. Alekseev
    Metallurgist, 2018, 62 : 3 - 9
  • [23] Applications of magnetic sector ICP-MS in geochemistry
    Gäbler, HE
    JOURNAL OF GEOCHEMICAL EXPLORATION, 2002, 75 (1-3) : 1 - 15
  • [24] ICP-MS for specific detection in capillary electrophoresis
    Alvarez-Llamas, G
    de laCampa, MD
    Sanz-Medel, A
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (01) : 28 - 36
  • [25] Analysis of Wastewater by ICP-MS
    Yakimovich, P. V.
    Alekseev, A. V.
    METALLURGIST, 2018, 62 (1-2) : 3 - 9
  • [26] Lanthanum metal by ICP-MS
    Liu, PY
    JOURNAL OF RARE EARTHS, 2000, 18 (03) : 109 - 112
  • [27] Single-cell ICP-MS to address the role of trace elements at a cellular level
    Silva, Ana Beatriz Santos da
    Arruda, Marco Aurelio Zezzi
    JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY, 2023, 75
  • [28] Elemental analysis of white cotton fiber evidence using solution ICP-MS and laser ablation ICP-MS (LA-ICP-MS)
    Gallo, Jenny M.
    Almirall, Jose R.
    FORENSIC SCIENCE INTERNATIONAL, 2009, 190 (1-3) : 52 - 57
  • [29] Determination of inorganic elements in rat serum, and vegetable and fruit ferment liquid by ICP-MS
    Li Xiang-yun
    Lian Hong-zhen
    Chen Yi-jun
    Hu Xin
    Mao Li
    Lu Ming
    Cai Yun-qing
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (09) : 2181 - 2186
  • [30] Isotopic measurements using ICP-MS: a tutorial review
    Alvarez Penanes, Pelayo
    Reguera Galan, Aida
    Huelga-Suarez, Gonzalo
    Angel Rodriguez-Castrillon, J.
    Moldovan, Mariella
    Garcia Alonso, J. Ignacio
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (04) : 701 - 726