The role of ICP-MS in inorganic chemical metrology

被引:26
作者
Sargent, M. [1 ]
Goenaga-Infante, H. [2 ]
Inagaki, K. [3 ]
Ma, L. [4 ]
Meija, J. [5 ]
Pramann, A. [6 ]
Rienitz, O. [6 ]
Sturgeon, R. [5 ]
Vogl, J. [7 ]
Wang, J. [4 ]
Yang, L. [5 ]
机构
[1] Sudell House Upper Brighton Rd, Surbiton KT6 6LB, England
[2] LGC Ltd, Queens Rd, Teddington TW11 0LY, Middx, England
[3] Natl Metrol Inst Japan, 1-1-1 Umezono, Tsukuba, Ibaraki 3058563, Japan
[4] Natl Inst Metrol, 18 Bei San Huan Dong Lu, Beijing 100029, Peoples R China
[5] Natl Res Council Canada, 1200 Montreal Rd, Ottawa, ON K1A 0R6, Canada
[6] PTB, Bundesallee 100, D-38116 Braunschweig, Germany
[7] Bundesanstalt Mat Forsch & Prufung BAM, Richard Willstatter Str 11, D-12489 Berlin, Germany
关键词
CCQM; metrology; interlaboratory comparison; ICP-MS; mass spectrometry; hyphenated; isotope ratio; INDUCTIVELY-COUPLED PLASMA; DILUTION MASS-SPECTROMETRY; STANDARD ADDITION EXPERIMENTS; AMOUNT RATIO MEASUREMENTS; LASER-ABLATION; ISOTOPE-RATIO; TRACE-METALS; ION-SOURCE; MEASUREMENT UNCERTAINTY; ANALYTICAL-CHEMISTRY;
D O I
10.1088/1681-7575/ab0eac
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
ICP-MS has played a key role in inorganic chemical metrology for 25 years, from the 1993 CIPM feasibility study which led to establishment of the CCQM. Since that time, the Inorganic Analysis Working Group of the CCQM has organised 56 international comparisons involving measurements by ICP-MS and, in a recent comparison, 16 different national institutes submitted their results using the technique. Metrological applications of ICP-MS currently address an enormous range of measurements using a wide variety of instrumentation, calibration strategies and methodologies. This review provides an overview of the ICP-MS field with an emphasis on developments which are of particular relevance to chemical metrology. Examples from CCQM comparisons and the services available from the participants are used to illustrate how the capability and scope of ICP-MS methods have expanded far beyond the expectations of 1993. This is due in part to the research and development programmes of the national institutes which participate in the CCQM. They have played a key role in advancing new instrumentation and applications for elemental analysis, isotope dilution mass spectrometry, determination of isotopic ratio or composition, and speciation of organometallic compounds. These developments are continuing today, as demonstrated by work in new fields such as heteroatom quantitation of proteins, characterisation and counting of nanoparticles using spICP-MS, and LA-ICP-MS analysis of solid materials.
引用
收藏
页数:31
相关论文
共 193 条
[1]   Determination of trace sulfur in biodiesel and diesel standard reference materials by isotope dilution sector field inductively coupled plasma mass spectrometry [J].
Amais, Renata S. ;
Long, Stephen E. ;
Nobrega, Joaquim A. ;
Christopher, Steven J. .
ANALYTICA CHIMICA ACTA, 2014, 806 :91-96
[2]  
[Anonymous], 2004, DEANS ANAL CHEM HDB
[3]  
[Anonymous], 2008, EVALUATION MEASUREME
[4]  
[Anonymous], 2008, Evaluation of Measurement Data-Guide to the Expression of Uncertainty in Measurement. JCGM 100:2008 (GUM 1995 with Minor Corrections)
[5]   CCQM-K24 key comparison. Cadmium amount content in rice [J].
Aregbe, Y. ;
Taylor, P. .
METROLOGIA, 2003, 40
[6]   Not Normal: the uncertainties of scientific measurements [J].
Bailey, David C. .
ROYAL SOCIETY OPEN SCIENCE, 2017, 4 (01)
[7]   Inductively coupled plasma - Tandem mass spectrometry (ICP-MS/MS): A powerful and universal tool for the interference-free determination of (ultra) trace elements - A tutorial review [J].
Balcaen, Lieve ;
Bolea-Fernandez, Eduardo ;
Resano, Martin ;
Vanhaecke, Frank .
ANALYTICA CHIMICA ACTA, 2015, 894 :7-19
[8]   A dynamic reaction cell for inductively coupled plasma mass spectrometry (ICP-DRC-MS) - Part 1. The rf-field energy contribution in thermodynamics of ion-molecule reactions [J].
Baranov, VI ;
Tanner, SD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (08) :1133-1142
[9]   Force calibration using errors-in-variables regression and Monte Carlo uncertainty evaluation [J].
Bartel, Thomas ;
Stoudt, Sara ;
Possolo, Antonio .
METROLOGIA, 2016, 53 (03) :965-980
[10]   IDENTIFICATION AND QUANTITATION OF ARSENIC SPECIES IN A DOGFISH MUSCLE REFERENCE MATERIAL FOR TRACE-ELEMENTS [J].
BEAUCHEMIN, D ;
BEDNAS, ME ;
BERMAN, SS ;
MCLAREN, JW ;
SIU, KWM ;
STURGEON, RE .
ANALYTICAL CHEMISTRY, 1988, 60 (20) :2209-2212