Comprehensive study on solar air heater with circular and V-type turbulators attached on absorber plate

被引:91
作者
Rajaseenivasan, T. [1 ]
Srinivasan, S. [1 ]
Srithar, K. [1 ]
机构
[1] Thiagarajar Coll Engn, Dept Mech Engn, Madurai 625015, Tamil Nadu, India
关键词
Solar air heater; Circular turbulator; V-shape turbulator; Exergy analysis; Thermal enhancement factor; Performance study; EXERGETIC PERFORMANCE EVALUATION; THERMAL PERFORMANCE; RIB ROUGHNESS; THERMOHYDRAULIC PERFORMANCE; FLOW CHARACTERISTICS; TRANSFER ENHANCEMENT; DOWN RIB; FRICTION; CHANNEL; SINGLE;
D O I
10.1016/j.energy.2015.07.020
中图分类号
O414.1 [热力学];
学科分类号
摘要
Performance enrichment in a single pass SAH (solar air heater) with circular and V-shape inserts are considered in this paper. Two identical SAH; conventional and modified SAH are tested with different Reynolds number ranging from 6000 to 12,000. Circular and V-shape turbulators are fixed in the absorber plate of modified SAH at six different configurations; inline arrangements with 4 x 4 (type-a), 5 x 4 (type-b), 6 x 4 (type-c) and 6 x 4 zigzag arrangement of circular inserts (type-d). Experiments are extended by introducing V-type inserts in convex (type-e) and concave shape (type-f) to create additional turbulence motion. Experiment results revealed that the system efficiency increases with Reynolds number and number of turbulators in absorber plate. Air temperature reaches an upper value of 66 degrees C in type-f with the mass flow rate of 57.7 kg/hr. Nusselt number increases with the Reynolds number and reaches the maximum of 210 for type-f turbulators at Reynolds number of 11615. Thermal enhancement factor decreases with increase in Reynolds number for all modifications. First law, thermohydraulic and second law efficiency increases up to 85%, 63% and 45% respectively for type-f at Reynolds number of 11615. Theoretical analysis also carried out and agrees well with experimental results. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:863 / 873
页数:11
相关论文
共 39 条
[1]   Single and double pass solar air heaters with wire mesh as packing bed [J].
Aldabbagh, L. B. Y. ;
Egelioglu, F. ;
Ilkan, M. .
ENERGY, 2010, 35 (09) :3783-3787
[2]   Thermal performance of an air solar collector with an absorber plate made of recyclable aluminum cans [J].
Alvarez, G ;
Arce, J ;
Lira, L ;
Heras, MR .
SOLAR ENERGY, 2004, 77 (01) :107-113
[3]   Analysis of heat transfer augmentation and flow characteristics due to rib roughness over absorber plate of a solar air heater [J].
Chaube, A ;
Sahoo, PK ;
Solanki, SC .
RENEWABLE ENERGY, 2006, 31 (03) :317-331
[4]   ENHANCEMENT OF CONVECTIVE HEAT-TRANSFER IN RECTANGULAR DUCTS OF INTERRUPTED SURFACES [J].
DUBROVSKY, EV ;
VASILIEV, VY .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1988, 31 (04) :807-818
[5]   Investigation of thermal performance of-double pass-flat and v-corrugated plate solar air heaters [J].
El-Sebaii, A. A. ;
Aboul-Enein, S. ;
Ramadan, M. R. I. ;
Shalaby, S. M. ;
Moharram, B. M. .
ENERGY, 2011, 36 (02) :1076-1086
[6]   Heat transfer enhancement by delta-wing vortex generators ion a flat plate: Vortex interactions with the boundary layer [J].
Gentry, MC ;
Jacobi, AM .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1997, 14 (03) :231-242
[7]   Exergetic performance evaluation and parametric studies of solar air heater [J].
Gupta, M. K. ;
Kaushik, S. C. .
ENERGY, 2008, 33 (11) :1691-1702
[8]   Thermohydraulic performance of air heating solar collectors with variable width, flat absorber plates [J].
Hegazy, AA .
ENERGY CONVERSION AND MANAGEMENT, 2000, 41 (13) :1361-1378
[9]   Studies on heat transfer and friction factor characteristics of thermosyphon solar water heating system with helical twisted tapes [J].
Jaisankar, S. ;
Radhakrishnan, T. K. ;
Sheeba, K. N. .
ENERGY, 2009, 34 (09) :1054-1064
[10]   Performance analysis of new-design solar air collectors for drying applications [J].
Karsli, Suleyman .