Trace level determination of perfluorinated compounds in water by direct injection

被引:60
|
作者
Furdui, Vasile I. [1 ,2 ]
Crozier, Patrick W. [2 ]
Reiner, Eric J. [2 ]
Mabury, Scott A. [1 ]
机构
[1] Univ Toronto, Dept Chem, Toronto, ON M5S 3H6, Canada
[2] Lab Serv Branch, Ontario Minist Environm, Etobicoke, ON M9P 3V6, Canada
关键词
perfluorinated compounds; PFOS; PFOA; quantification bias; Great Lakes;
D O I
10.1016/j.chemosphere.2007.07.085
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A new, fast LC-MS/MS method for the determination of perfluorinated surfactants in water samples by direct injection without pre-concentration is reported. The current method requires only 4 min to analyze nine perfluoroalkyl compounds in a single analytical run. Standard addition and internal standard quantification were used to determine the level of some perfluorinated carboxylic and sulfonic acids, including perfluorooctanoic sulfonate (PFOS) and perfluorooctanoic acid (PFOA), in Great Lakes water samples. Statistically significant differences were observed between the results obtained using different quantification methods. A relatively small difference between the PFOS values obtained with the standard addition method, with and without peak area normalization, clearly indicates that standard addition is the best quantification method when mass-labeled standards are not available. Based on the paired t-test statistical analysis, the concentrations calculated using external standardization were the least accurate, with the highest mean difference from the standard addition calculated values. Both PFOS and PFOA were present at less than 10 ng l(-1) in all Great Lake samples. Higher levels were detected in tributaries of Lake Ontario and effluents from sewage treatment plants. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S24 / S30
页数:7
相关论文
共 50 条
  • [1] Determination of trace level bromate in drinking water by direct injection ion chromatography
    Jackson, LK
    Joyce, RJ
    Laikhtman, M
    Jackson, PE
    JOURNAL OF CHROMATOGRAPHY A, 1998, 829 (1-2) : 187 - 192
  • [2] Determination of genotoxic epoxide at trace level in drug substance by direct injection GC/MS
    Chen, Liqin
    Zhang, Wei
    Hu, Steven
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 146 : 103 - 108
  • [3] Determination of trace level ions by high-volume direct-injection ion chromatography
    Kaiser, E
    Riviello, J
    Rey, M
    Statler, J
    Heberling, S
    JOURNAL OF CHROMATOGRAPHY A, 1996, 739 (1-2) : 71 - 79
  • [4] Analysis of volatile trace sulfur compounds in water with GC-SCD by direct aqueous injection
    Tang, H
    Heaton, P
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1996, 62 (04) : 263 - 271
  • [5] DETERMINATION OF WATER BY DIRECT INJECTION ENTHALPIMETRY
    REYNOLDS, CA
    HARRIS, MJ
    ANALYTICAL CHEMISTRY, 1969, 41 (02) : 348 - &
  • [6] Analysis of volatile trace sulfur compounds in water with GC-SCD by direct aqueous injection
    Chemex, 9331 48 St, Edmonton, T6G 2R4, Canada
    INT. J. ENVIRON. ANAL. CHEM., 4 (263-271):
  • [7] Determination of trace levels of haloacetic acids and perchlorate in drinking water by ion chromatography with direct injection
    Liu, YJ
    Mou, SF
    JOURNAL OF CHROMATOGRAPHY A, 2003, 997 (1-2) : 225 - 235
  • [8] Determination of ultra-trace bisphenol A in water samples by chromatography with large volume direct injection
    Jiang Ming
    Lin Yi
    Zhang Jianghua
    Mei Surong
    Lu Bin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (10) : 1419 - 1422
  • [9] Research Progresses of Determination of Perfluorinated Compounds in Environmental Water and Solid Samples
    Sun Teng-Fei
    Xiang Lei
    Chen Lei
    Xiao Tao
    Mo Ce-Hui
    Li Yan-Wen
    Cai Quan-Ying
    Hu Guo-Cheng
    He De-Chun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (04) : 601 - 609
  • [10] TRACE DETERMINATION OF VINYL-CHLORIDE IN WATER BY DIRECT AQUEOUS INJECTION GAS CHROMATOGRAPHY MASS SPECTROMETRY
    FUJII, T
    ANALYTICAL CHEMISTRY, 1977, 49 (13) : 1985 - 1987