Safe and Accurate: Learning the Direct Anterior Total Hip Arthroplasty

被引:3
作者
Masonis, John [1 ]
Thompson, Caryn [1 ]
Odum, Susan [1 ]
机构
[1] OrthoCarolina Hip & Knee Ctr, Charlotte, NC 28204 USA
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Wear, instability, leg length, and muscle recovery are the major obstacles into total hip arthroplasty(THA). The direct anterior approach with fluoroscopic assistance has been proposed to address all four of these issues, The goal of this study was to assess the learning curve, safety, and accuracy of direct anterior THA. A retrospective review was completed on a single surgeon's initial consecutive. series of 300 THAs performed via a direct anterior approach. Cases were grouped based on chronologic order (1-100, 101-200, 201-300). Operative time, fluoroscopy time, estimated blood loss, radiographic leg length discrepancy (LLD) radiographic cup abduction angle, and complications were recorded. Data we're analyzed using an analysis of variance. Postoperatively, all patients were managed I without dislocation precautions. The average age for the cohort was 58.9 years, and the average BMI was. 29. All groups were similar with respect to age and BMI. Direct anterior THA demonstrated significant reductions inoperative and,flouroscopy after the first 100 cases. Mean Surgery time was 132.8 minutes for, group 1, 109.9 for group 2, and 106.1 for group 3 (P<.001). Mean flouroscopy time was 32.1 seconds for group 1, 14.5 for group 2, and 14.5 for group (P<.001). There was one dislocation in group 3 and three intraoperative calcar fractures in the first cases. There were no infections. Direct anterior THA demonstrated a reduction. in operative time and fluoroscopy time after the initial 100 cases. Calcar fracture did not occur after the first 62 cases. Cup abduction dislocation rate, and LLD were excellent. in all groups.
引用
收藏
页码:129 / 134
页数:6
相关论文
共 13 条
  • [1] Cerclage wires or cables for the management of Intraoperative fracture associated with a cementless, tapered femoral prosthesis
    Berend, KR
    Lombardi, AV
    Mallory, TH
    Chonko, DJ
    Dodds, KL
    Adams, JB
    [J]. JOURNAL OF ARTHROPLASTY, 2004, 19 (07) : 17 - 21
  • [2] Single-incision, minimally invasive total hip arthroplasty - Length doesn't matter
    de Beer, J
    Petruccelli, D
    Zalzal, P
    Winemaker, MJ
    [J]. JOURNAL OF ARTHROPLASTY, 2004, 19 (08) : 945 - 950
  • [3] DAS UNIPOLARE ELEKTROKARDIOGRAMM
    JENSEN, J
    [J]. DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1947, 72 (39-4) : 561 - 565
  • [4] THE USE OF AN ARTIFICIAL FEMORAL HEAD FOR ARTHROPLASTY OF THE HIP JOINT
    JUDET, J
    JUDET, R
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1950, 32 (02): : 166 - 173
  • [5] Comparison of primary total hip arthroplasties performed with a minimally invasive technique or a standard technique - A prospective and randomized study
    Kim, Young-Hoo
    [J]. JOURNAL OF ARTHROPLASTY, 2006, 21 (08) : 1092 - 1098
  • [6] LIGHT TR, 1980, CLIN ORTHOP RELAT R, P255
  • [7] MASONIS JL, 2002, CLIN ORTHOP RELAT R, V405, P46
  • [8] Single-incision anterior approach for total hip arthroplasty on an orthopaedic table
    Matta, JM
    Shahrdar, C
    Ferguson, T
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (441) : 115 - 124
  • [9] NAKATA K, 2007, AAOS M FEB 15 SAN DI
  • [10] Polyethylene wear and acetabular component orientation
    Patil, S
    Bergula, A
    Chen, PC
    Colwell, CW
    D'Lima, DD
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A : 56 - 63