Analysis of specific migration of monomers and oligomers from polyethylene terephthalate bottles and trays according to the testing methods as prescribed in the legislation of the EU and Asian countries

被引:29
作者
Kim, Dong-Joo [1 ]
Lee, Keun Taik [1 ]
机构
[1] Gangneung Wonju Natl Univ, Dept Food Sci, Kangnung 210702, Gangwon, South Korea
关键词
Polyethylene Terephthalate; Monomers; Oligomers; Specific migration; Food simulants; HPLC; PET BOTTLES; UV STABILIZER; MINERAL-WATER; FOOD; POLY(ETHYLENE-TEREPHTHALATE); ACETALDEHYDE;
D O I
10.1016/j.polymertesting.2012.07.012
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Specific migration levels of monomers and oligomers in polyethylene terephthalate (PET) food containers were determined using HPLC according to the migration testing methods specified by the relevant legislations of the EU and Asian countries (e.g. Korea and Japan). The results of migration from PET bottles and trays using non-fatty simulants under the testing conditions (60 degrees C/0.5 h) of Asian countries indicated that the values of various monomers and oligomers (TPA, MHET, BHET, A2 group, A3 group, S2 group, S3 group, cyclic dimer, and cyclic trimer) were in between 0.0 and 0.58 mu g dm(-2). On the other hand, those obtained with the EU conditions (40 degrees C/10 days) were in the range of 0.0 to 0.94 mu g dm(-2). The specific migration values of monomers and oligomers into non-fatty simulants tended to be generally higher in testing under the EU conditions than under Asian conditions. Furthermore, when PET samples were tested for migration from fatty foods simulants using n-heptane (at 25 degrees C/1 h as per Asian conditions) or iso-octane (at 20 degrees C/48 h as per EU conditions), only cyclic trimer was detected at levels of 0.36 to 1.05 mu g dm(-2) and 0.05 to 0.55 mu g dm(-2), respectively. The use of 95% ethanol as an alternative fatty food simulant for the migration tests of PET would be inappropriate, since it might cause overestimated migration compared to the use of other simulants such as n-heptane and iso-octane. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1001 / 1007
页数:7
相关论文
共 26 条
[1]  
Bach C., 2009, IOP C SERIES MAT SCI, V5, P1
[2]   ALTERNATIVE FATTY FOOD SIMULANTS FOR MIGRATION TESTING OF POLYMERIC FOOD CONTACT MATERIALS [J].
BANER, A ;
BIEBER, W ;
FIGGE, K ;
FRANZ, R ;
PIRINGER, O .
FOOD ADDITIVES AND CONTAMINANTS, 1992, 9 (02) :137-148
[3]   Migration of a UV stabilizer from polyethylene terephthalate (PET) into food simulants [J].
Begley, TH ;
Biles, JE ;
Cunningham, C ;
Piringer, O .
FOOD ADDITIVES AND CONTAMINANTS, 2004, 21 (10) :1007-1014
[4]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF MIGRATING POLY(ETHYLENE-TEREPHTHALATE) OLIGOMERS IN CORN-OIL [J].
BEGLEY, TH ;
HOLLIFIELD, HC .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1990, 38 (01) :145-148
[5]   MIGRATION INTO FOOD OF POLYETHYLENE TEREPHTHALATE (PET) CYCLIC OLIGOMERS FROM PET MICROWAVE SUSCEPTOR PACKAGING [J].
BEGLEY, TH ;
DENNISON, JL ;
HOLLIFIELD, HC .
FOOD ADDITIVES AND CONTAMINANTS, 1990, 7 (06) :797-803
[6]   Acetaldehyde residue in polyethylene terephthalate (PET) bottles [J].
Choodum, Aree ;
Thavarungkul, Panote ;
Kanatharana, Proespichaya .
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART B-PESTICIDES FOOD CONTAMINANTS AND AGRICULTURAL WASTES, 2007, 42 (05) :577-583
[7]  
Cooper I, 1998, FOOD ADDIT CONTAM, V15, P72
[8]   Extraction of oligomers from poly(ethylene terephthalate) by microwave-assisted extraction [J].
Costley, CT ;
Dean, JR ;
Newton, I ;
Carroll, J .
ANALYTICAL COMMUNICATIONS, 1997, 34 (03) :89-91
[9]   Aldehyde contamination of mineral water stored in PET bottles [J].
Dabrowska, A ;
Borcz, A ;
Nawrocki, J .
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2003, 20 (12) :1170-1177
[10]   DSC studies on the crystallization characteristics of poly(ethylene terephthalate) for blow molding applications [J].
Fann, DM ;
Huang, SK ;
Lee, JY .