Surgical smoke simulation study: Physical characterization and respiratory protection

被引:23
作者
Elmashae, Yousef [1 ]
Koehler, Richard H. [2 ]
Yermakov, Michael [1 ]
Reponen, Tiina [1 ]
Grinshpun, Sergey A. [1 ]
机构
[1] Univ Cincinnati, Ctr Hlth Related Aerosol Studies, Dept Environm Hlth, POB 670056, Cincinnati, OH 45220 USA
[2] Marthas Vineyard Hosp, Dept Surg, 1 Hosp Rd, Oak Bluffs, MA 02557 USA
关键词
CHEMICAL-COMPOSITION; N95; RESPIRATORS; LASER SMOKE; PLUME; PERFORMANCE; SURGERY; WORKERS; MASKS;
D O I
10.1080/02786826.2017.1373180
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Exposure of operating room (OR) personnel to surgical smoke, a unique aerosol generated from the common use of electrocautery during surgical procedures, is an increasing health risk concern. The main objective of this simulation study was to characterize the surgical smoke exposure in terms of the particle number concentration and size distribution in a human breathing zone. Additionally, the performance of respiratory protective devices designed for ORs was examined using two commercially available N95 facepiece filtering respirators (FFRs) as well as the same FFRs modified with new faceseal technology. The tests were conducted in an OR-simulating exposure chamber with the surgical smoke generated by electrocautery equipment applied to animal tissue and measured in the breathing zone with four aerosol spectrometers. The simulated workplace protection factor of each tested respirator was determined for ten subjects by measuring the total aerosol concentrations inside and outside of a respirator. The peak of the particle size distribution was in a range of 60-150 nm. The concentration of particles generated during the simulated surgical procedure significantly exceeded the background concentration under all tested air exchange conditions. The data suggest that wearing N95 filtering facepiece respirators significantly decreased the human exposure to surgical smoke. The new faceseal technology provided significantly higher respiratory protection than the commercial N95 FFRs.
引用
收藏
页码:38 / 45
页数:8
相关论文
共 31 条
[1]   Surgical smoke and infection control [J].
Alp, E ;
Bijl, D ;
Bleichrodt, RP ;
Hansson, B ;
Voss, A .
JOURNAL OF HOSPITAL INFECTION, 2006, 62 (01) :1-5
[2]  
[Anonymous], 2014, DESIGN CONSTRUCTION
[3]  
[Anonymous], 1997, Federal Register, V60, P30335
[4]   THE EFFECTS OF LASER SMOKE ON THE LUNGS OF RATS [J].
BAGGISH, MS ;
ELBAKRY, M .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1987, 156 (05) :1260-1265
[5]   PROTECTION OF THE RAT LUNG FROM THE HARMFUL EFFECTS OF LASER SMOKE [J].
BAGGISH, MS ;
BALTOYANNIS, P ;
SZE, E .
LASERS IN SURGERY AND MEDICINE, 1988, 8 (03) :248-253
[6]   Surgical smoke - a review of the literature - Is this just a lot of hot air? [J].
Barrett, WL ;
Garber, SM .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2003, 17 (06) :979-987
[7]   Surgical smoke and ultrafine particles [J].
Brüske-Hohlfeld I. ;
Preissler G. ;
Jauch K.-W. ;
Pitz M. ;
Nowak D. ;
Peters A. ;
Wichmann H.-E. .
Journal of Occupational Medicine and Toxicology, 3 (1)
[8]  
Capizzi PJ, 1998, LASER SURG MED, V23, P172, DOI 10.1002/(SICI)1096-9101(1998)23:3<172::AID-LSM7>3.0.CO
[9]  
2-M
[10]   Survival of a Surrogate Virus on N95 Respirator Material [J].
Casanova, Lisa M. ;
Waka, Behelhem .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2013, 34 (12) :1334-1335